HomeMy WebLinkAbout857 Campfire Dr - Disclosures/Air Sealing - 03/21/2013BUILDING blx5q'5�1 G LEAKAGE TEST Date of Test: 3/21 /2013 Test File: DR Horton Blower door Customer: DR Horton 7600 E Orchard Rd #350-S Greenwood Village, Colorado 80111 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: Technician: Doug Groff Building Address: 857 Campfire Drive Fort Collins, Colorado 80524 1162CFM (+/-0.1%) 2.37 ACH 0.32 CFM per ft2 floor area 266.6 in2 (+/ 1.3 %) Canadian EgLA @ 10 Pa 223.3 in2 (+/ 2.0 %) LBL ELA @ 4 Pa 0.17 CFM50 per ft2 surface area Flow Coefficient (C) = 636.5 ( +/- 3.0 %) Exponent (n) = 0.154 ( +/- 0.008 ) Correlation Coefficient = 0.99644 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 181.1 CFM 0.37 ACH 2. Estimated Design Infiltration Rate: Winter: 282.8 CFM 0.58 ACH Summer: 168.3 CFM 0.34 ACH 3. Recommended Whole Building Mechanical 12.4 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 3/21/2013 Test File: DR Horton Blower door Building Conditions Inside Temperature: 72 deg F Heating Fuel: Gas Outside Temperature: 52 deg F Heating Fuel Cost: # of Stories 1.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 3.0 Volume: 29382 ft3 Ventilation Weather Factor: 0.87 Surface Area: 6819 ft2 Energy Climate Factor: 17.0 Floor Area: 3648 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments Garage WRT House: 45.5 Pa @ 50 Pa BUILDING LEAKAGE TEST Page 3 Date of Test: 3/21 /2013 Test File: DR Horton Blower door Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) 1.9 n/a +/- 0.00 -65.0 46.8 1240 1216 0.1 Ring A -60.0 45.7 1225 1202 0.1 Ring A -55.0 44.1 1205 1182 -0.3 Ring A -50.0 43.0 1190 1167 -0.1 Ring A -45.0 41.9 1175 1153 0.2 Ring A BURGESS COLORADO DIVISION DR HORTON - COLORADO HERS FINAL INSPECTION BADDRESS: 857 Campfire Dr DATE: CITY: Fort Collins PO#: CONSTRUCTION COMMUNITY: Trail Head - Ft. Collins JOB#: CONSULTANTS BUILDER: DR Horton - Colorado INSPECTION ID#: SINCE . BCCI REP: Doug Groff 303-598-8267 STATUS: ITEMS NOT COMPLETED: 0 REPAIR SUMMARY: ENERGY 0 Inspection Notes: 1 Blower Door Test Passed @: 1190 CFM 2 HOME CONFIRMED, stickers printed N/C Items: 3/21/2013 211823 ON 1886 Plan 705102 Passed BURGESS C CONSTRUCTION CONSULTANTS INC. SINCE 1986 COLORADO DIVISION DR HORTON - COLORADO HERS THERMAL BYPASS FINAL INSPECTION ADDRESS: 857 Campfire Dr CITY: Fort Collins COMMUNITY: Trail Head - Ft. Collins BUILDER: DR Horton - Colorado BCCI REP: Doug Groff 303-598-8267 ITEMS NOT COMPLETED: 0 REPAIR SUMMARY: ADDITIONAL Inspection Notes: No notes entered. N/C Items: 0 THERMAL BYPASS,0 FINAL DATE:' 3/21/2013 POM JOBM 1886 Plan INSPECTION ID#: 705101 STATUS: Passed Air Leakage Property Organization DR Horton Burgess Inc. 857 Campfire Drive 303-300-4527 Fort Collins, CO 80524 Robert Hutchinson Weather: Denver, CO Builder Trail Head 1886 DR Horton 857 Campfire Drive.blg Whole House Infiltration HERS Projected Rating 10/5/2012 Rating No: Worst Case Scenario RaterID:7479033 Blower Door Test Heating I Cooling CONSTRUCTION CONSULTANTS INC. Natural ACH ACH @ 50 Pascals 0.11 2.43 0.09 2.43 CFM @ 25 Pascals 758 758 CFM @ 50 Pascals 1190 1190 Eff. Leakage Area (sq.in) 65.3 65.3 Specific Leakage Area 0.00012 0.00012 ELA/100 sf shell (sq.in) 0.% 0.96 Duct Leakage Leakage to Outside Units Hvac CFM @ 25 Pascals 0 CFM25 / CFMfan 0.0000 CFM25 / CFA 0.0000 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 0 Eff. Leakage Area (sq.in) 0.00 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0241 Ventilation Mechanical Sensible Recovery Eff. (%) Total Recovery Eff. (%) Rate (cfm) Hours/Day Fan Watts Cooling Ventilation Exhaust Only 0.0 0.0 66 24.0 11.3 Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements SINCE 1986 For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings, a minimum of 66 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 133 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate - Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. O 1985-2013 Architectural Energy Corporation, Boulder, Colorado.