Loading...
HomeMy WebLinkAbout827 Campfire Dr - Disclosures/Final Energy - 02/13/2013BURGESS n e �j� 1;�70wr(�q & ' 5000s 2313 I ' V 827 Campfire Drive "( C Fort Collins, CO 80524 CONSTRUCTION CONSULTANTS INC. S""1 9 46 5 Stars Plus Confirmed Uniform Energy Rating System Energy Efficient 1 Star 1 Star Plus 2 Stars 1 2 Stars Plus 1 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less HERS Index: 65 Efficient Home Comparison: 35% Better Conditioned Area: 3472 sq. ft. HouseType: Single-family detached Conditioned Volume: 28523 cubic ft. Foundation: More than one type Bedrooms: 3 y= Mechanical: -Systems Features �yv _ i� °( Heating: Fuel -fired air distribution, Natural gas, 92.OAFUE. Water Heating: Conventional, Natural gas, 0.60 EF, 40.0 Gal. Duct Leakage to Outside: 0.00 CFM. Ventilation System: Exhaust Only: 65 cfm, 11.3 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building;She11 Features" — _ _d Ceiling Flat: R-38 _ Exposed Floor_ R-30 Vaulted Ceiling: NA Window Type: D/LoE- Vinyl 3430"""" Above Grade Walls: R-15, R-19 Infiltration: Foundation Walls: R-11.0 Rate: Htg: 1200 Clg: 1200 CFM50 Slab: R-0.0 Edge, R-0.0 Under Method: Blower door test LtghtsandApplianceFeatures Percent Interior Lighting: 10.00 Range/Oven Fuel: Natural gas Percent Garage Lighting: 0.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 775.00 Clothes Dryer EF: 2.67 Dishwasher Energy Factor: 0.68 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. © 1985-2012Architectural Energy Corporation, Boulder, Colorado. Registry ID: Rating Number: Certified Energy Rater: Rating Date: Rating Ordered For: 380835096 Worst Case Scenario DE Robert Hutchinson 2/13/2013 DR Horton Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 66.1 $459 27% Cooling 0 $0 0% Hot Water 19.8 $129 8% Lights/Appliances 35.8 $884 53% Photovoltaics -0.0 $-0 -0% Service Charges $204 12% Total $1677 100% This home meets or exceeds the minimum criteria for all of the following: EPA ENERGY STAR Version 2 Home 2006 International Energy Conservation Cade 2009 International Energy Conservation Code MOPTGAGf Burgess Construction Consultant: G�" iti0` 101 W. Renner Road, Suite 400 Richardson, TX 75082 r i 214-888-7300 1 No.71998-144 214-888-7266 ps9 ire 7479033 cCgfmTwT'o?;C Certified Energy Rater BURGESS FIX] CONSTRUCTION CONSULTANTS INC. aoce ww. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: February 14, 2013 Rating No.: Worst Case Scenario DE Building Name: 5000s 2313 Rating Org.: Burgess, Inc Owner's Name: DR Horton Phone No.: 303-300-4527 Property: 827 Campfire Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO80524 Rater'sNo.: 7479033 Builder's Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 827 Campfire Drive.blg Rating Date: 2/13/2013 Annual Energy Cost ($) FC 2012 As Designed Heating: 630 540 Cooling: 139 93 Water Heating: 128 128 SubTotal • Used to Determine Compliance: 897 760 Lights &Appliances: 898 884 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1999 1849 Mandatory Requirements: Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher) 6.0 8.0 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.340 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the re yffements by 15.2%. Name: Robert Hutchinson Signature: \\ 7479033 Organization: Burgess, Inc Date: F bruary 14, 2013 REM/Rate • Residential Energy Analysis and Rating Software 03.0 This information does not constitute any warranty of energy cost or savings. ©1985-2012Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT 5000s2313 Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 80.0 kBtuh, 92.0 AFUE. Water Heating: Conventional, Gas, 0.60 EF. Cooling:Airconditioner, 17.6 kBtuh, 13.0 SEER. Window -to -Floor Area Ratio: 0.11 Blower door test: Htg: 1200 Clg: 1200 CFM50 Page 2 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software 03.0 This information does not constitute any warranty of energy cost or savings. ©1985-2012Architectural Energy Corporation, Boulder, Colorado. BURGESS F101 CONSTRUCTION CONSULTANTS INC. m FLM FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: February 13, 2013 Rating No.: Worst Case Scenario DE Building Name: 5000s 2313 Rating Org.: Burgess, Inc Owners Name: DR Horton Phone No.: 303-3004527 Property: 827 Campfire Drive Raters Name: Robert Hutchinson Address: Fort Collins, CO 80524 Raters No.: 7479033 Builders Name: DR Horton Weather Site: Ft Collins, CO Rating Type: Confirmed File Name: 827 Campfire Drive.blg Rating Date: 2/13/2013 Annual Energy Cost (S) FC 2012 As Designed Heating: 630 540 Cooling: 139 93 Water Heating: 128 128 SubTotal - Used to Determine Compliance: 897 760 Lights & Appliances: 898 884 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1999 1849 ` Mandatory Requirements: Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher) 6.0 8.0 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.340 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Sec ti0 of 09 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this h me s p s the requirements by 15.2%. Name: Robert Hutchinson Signature. Organization: Burgess, Inc Date: Februa , 2013 REM/Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. 01985-2012Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT 5000s 2313 Page 2 Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 80.0 kBtuh, 92.0AFUE. Water Heating: Conventional, Gas, 0.60 EF. Cooling: Air conditioner, 17.6 kBtuh, 13.0 SEER. Window -to -Floor Area Ratio: 0.11 Blower door test Htg: 1200 Clg: 1200 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect currentfederal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software A3.0 This information does not constitute any warranty of energy cost or savings. 0 1985-2012 Architectural Energy Corporation, Boulder, Colorado.