HomeMy WebLinkAbout2601 Bar Harbor Dr - Disclosures/Air Sealing - 04/09/2013Date of Test: 4-9-13 Customer: Journey Homes Greeley, CO 80634 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: 4. Test Settings: BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Q Test File: Journey Homes 2601 Bar Harbor -BD Technician: Paul Higman Project Number: Building Address: 2601 Bar Harbor ' Fort Collins, CO 80524 931 CFM50 (+/- 0.6 %) 3.41 ACH50 0.5261 CFM50/ft2 floor area 71.1 in2 (+/- 2.7 %) Canadian EgLA @ 10 Pa 31.9in2(+/-4.4%)LBLELA@4Pa Flow Coefficient (C) = 35.2 ( +/- 6.9 %) Exponent (n) = 0.837 ( +/- 0.019 ) Correlation Coefficient = 0.99851 Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 31.6 CFM 0.12 ACH 2. Estimated Design Infiltration Rate: Winter: 53.8 CFM Summer: 30.2 CFM 0.20 ACH 0.11 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 4-9-13 Test File: Journey Homes 2601 Bar Harbor-BD Building Information Location Climate Information Volume 16388 Ventilation Weather Factor 0.87 Surface Area Energy Climate Factor 17.00 FloorArea 1770 Heating Degree Days 6020 Height 16 Cooling Degree Days 287 #of Bedrooms 3 Design Winter Wind Speed 9.0 mph #of Occupants Design Summer Wind Speed 7.0 mph Year of Construction 2013 Design Winter Temp Diff 69 deg F Wind Shield M Design Summer Temp Diff 16 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 4-9-13 Test File: Journey Homes 2601 Bar Harbor-BD Depressurization Test: Environmental Data Indoor Temperature(°F) Outdoor Temperature (°F) 66.0 52.0 Data Points -Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.4 n/a n/a -55.0 -53.8 30.5 1006 993 0.3 Ring A -49.6 -48.4 25.3 919 907 0.1 Ring A -45.9 -44.6 202.5 843 832 -1.8 Ring B -39.9 -38.6 170.9 775 765 1.9 Ring B -35.2 -34.0 132.0 682 673 -0.1 Ring B -30.6 -29.4 103.7 605 597 0.1 Ring B -25.2 -23.9 69.4 496 489 -2.7 Ring B -20.5 -19.3 52.8 433 427 2.0 Ring B -1.1 n/a n/a Deviations from Standard CGSB -Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 4-9-13 Test File: Journey Homes 2601 Bar Harbor-BD Comments House wrt Garage = -48.2pa House wrt Mech room = Electric water heat