Loading...
HomeMy WebLinkAbout3144 Lower Loop Loop Dr - Disclosures/Final Energy - 03/25/2013BURGESS ��[%, L /t(/yyr Trail Head 1886 I �■ I V' � 3144 Lower Loop Drive lililll �p�p�p� I,I,I, Fort Collins, CO 80524 CONSTRUCTION. CONSULTANTS INC. X `^ SINCE 1986 5 Stars Plus Confirmed Uniform Energy Rating System Energy Efficient 1 Star 1 Star Plus 1 2 Stars 1 2 Stars Plus 1 3 Stars 3 Stars Plus 1 4 Stars 4 Stars Plus 1 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less HERS Index: R7 Efficient Home Comparison: Conditioned Area: 3648 sq. ft. HouseType: Conditioned Volume: 29382 cubic ft. Foundation: Bedrooms: 3 Heating: Fuel -fired air distribution, Natural gas, 92.OAFUE 33% Better Single-family detached More than one type Cooling: Air conditioner, Electric, 13.0 SEER. Water Heating: Conventional, Natural gas, 0.62 EF, 50.0 Gal. Duct Leakage to Outside: 0.00 CFM. Ventilation System: Exhaust Only: 66 cfm, 11.3 watts. Programmable Thermostat: Heating: Yes Cooling: Yes luilding Shell Features ` Ceiling Flat: R-38w/RB Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: NA Vaulted Ceiling: NA Window Type: Double -Vinyl 3530"'0""" Above Grade Walls: R-15 Infiltration Rate: Htg: 1125 Clg: 1125 CFM50 Foundation Walls: R-11.0, R-0.0 Method: Blower door test Percent Interior Lighting: 10.00 Range/Oven Fuel: Natural gas Percent Garage Lighting: 0.00 Clothes Dryer Fuel: Natural gas Refrigerator (kWh/yr): 775.00 Clothes Dryer EF: 2.67 Dishwasher Energy Factor: 0.68 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. © 1985-2013 Architectural Energy Corporation, Boulder, Colorado. Registry ID: 642360320 Rating Number: Certified Energy Rater: Robert Hutchinson Rating Date: 3/25/13 Rating Ordered For: DR Horton Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 47.5 $330 21% Cooling 2.7 $71 5% Hot Water 18.6 $121 8% Lights/Appliances 36.9 $843 54% Photovoltaics -0.0 $-O -0% Service Charges $204 13% Total 105.6 $1568 100% This home meets or exceeds the minimum criteria for all of the following: EPA ENERGY STAR Version 2 Home 2006 International Energy Conservation Code 2009 International Energy Conservation Code 'y MoFTC f''Y Burgess ConstructionConsultants o? 0 OA 101 W. Renner Road, Suite 400 2T v� Richardson, TX 75082 214-888-7300 No. 998-144 A¢' 214-888-7266 c ,,�,,�\\ sc `on f� 7479033 EDITTpe Certified Energy Rater BURGESS C COuSfRUCTiOV CONSULTAIQTS INC. xi�+ce wne FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON-ELECTRIC-HEAT Date: March 26,2013 Rating No.: Building Name: Trail Head 1886 Rating Org.: Burgess Inc. Owner's Name: DR Horton Phone No.: 3D3300-4527 Properly: 3144 Lower Loop Drive Rater's Name: Robert Hutchinson Address: Fort Collins,CO 80524 Rater's No.: 7479033 Builder's Name: DR Horton Weather Site: Denver,CO Rating Type: Confirmed File Name: 3144 Lower Loop Drive.big Rating Date: 3/25/13 Mnual Energy Cost($) FC 2012 As Designed Heating: 365 395 Cooling: 128 93 Water Heating: 120 120 SubTotal-Used to Determine Compliance: 614 608 Lights&Appliances: 857 843 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1675 1655 ' Window U-Factor Check(Section 402.5) Window U-Factor(Design must be equal or lower): 0.400 0.340 Home Infiltration(Section 402.4.2): PASSES Duct Leakage(Section 40322): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code,amended by the City of Fort Collins. In fact,this home surpasses the re i�ments by 0.9%. Name: Robert Hutchinson Signature: ��7479033 /� � Organization: Burgess Inc. Date: M�rch 26,2013 'Design energy cost is based on the following systems: Heating:Fuel-fired air distribution,80.0 kBtuh,92.OAFUE. Cooling:Air conditioner,36.0 kBtuh,13.0 SEER. Water Heating:Conventional,Gas,0.62 EF. Window-to-FloorArea Ratio:0.08 REM/Rate-Residential EnergyMalysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. OO 1985-2013Architectural EnergyCorporation,Boulder,Colorado. � FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON-ELECTRIC-HEAT Trail Head 1886 Page 2 Blower door test:Htg:1125 Clg:1125 CFM50 In accordance with IECC,building inputs,such as setpoints,infiltration rates,and window shading may have been changed prior to calculating annual energy cost. Furthermore,the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change,and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate-Residential EnergyAnalysis and Rating Software v14.2 This information does not constitule any warranty of energy cost or savings. �O 1985-2013 Architectural Energy Corporation,Boulder,Colorado. Fort Collins Energy Cost Compliance B�tGEss - Non Etectric Heat g Property Organization HERS _ DR Horton Burgess Inc. Confirmed CONSTRUCffON 3144 LowerLoop Drive 303-300-4527 3/25/13 CONSULTANTS Fort Collins, CO 80524 Robert Hutchinson Rating No:Worst Case INC. Scenario SINCE I986 Weather:Denver, CO Builder RaterID:7479033 Trail Head 1886 DR Horton 3144 Lower Loop Drive.blg Annual Energy Cost $/yr FC 2012 As Designed Heating 365 395 Cooling 128 93 Water Heating 120 120 -----. �a;- — — - __�_ _-- - - — ---------- ------ - -�-- — �Sub7otal Used to Determine'Comphance_^__ 614� 608� __. ...__,..�__..,��.--- -.--_-----_�_.�_. _�._____ _ Lights 8 Appliances 857 843 Photovoltaics -0 -0 Service Charge � 204 204 �Total -- -_ -- - ----------- - _—__-1675— �'�165� Mandatory Requirements Window U-Fador Check (Section 402.5) Window U-Factor(Design must be equal or lower) 0.400 0.340 Home Infiltration (Section 402.4.2) PASSES Duct Leakage,(Section 403.2.2) PASSES This home MEETS the annual energy cost requiremenu of Section 405 of the 2009 rnati al Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requiremen s by . Name Robert Hutchinson Signature �VG "�� Organization Burgess Inc. Date 25 March 13 Mechanical Systems Heating Fuel-fired air distribution, 80.0 kBtuh, 92.0 AFUE. Cooling Air conditioner, 36.0 kBtuh, 13.0 SEER. Water Heating Conventional, Gas, 0.62 EF. Window-to-Floor Area Ratio: 0.08 Blower door test Htg: 1125 Clg: 1125 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate- Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. O 1985-2013 Architectural Energy Corporation, Boulder, Colorado.