HomeMy WebLinkAbout1956 Mackinac St - Disclosures/Final Energy - 03/27/2013Uniform Energy Rating System RaC4�I? 1956 Mackinac Fort Collins, CO 80524 5 Stars Plus Confirmed Rating Energy Efficient 1 Star 1 Star Plus 2 Stars 1300-251 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500tar 400-301 250-201 200-151 150-10' 100-91 { 90-86 85-71 70 or Less HERS Index: 67 General Information Conditioned Area: 1710 sq. ft. HouseType: Single-family detached Conditioned Volume: 18014 cubic ft. Foundation: Conditioned crawl space Bedrooms: 3 Mechanical Systems Features Heating: Fuel -fired air distribution, Natural gas, 95.OAFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Water Heating: Conventional, Electric, 0.95 EF, 40.0 Gal. Duct Leakage to Outside: 37.00 CFM. Ventilation System: Exhaust Only: 62 cfm, 24.0 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building Shell Features Ceiling Flat: R-38 Exposed Floor: R-38 Vaulted Ceiling: NA Window Type: U.0.33,SHGCO.31 Above Grade Walls: R-19, R-15 Infiltration: Foundation Walls: R-19.0 Rate: Htg: 1187 Clg: 1187 CFM50 Slab: None Method: Blower door test Lights and Appliance Features Percent Interior Lighting: 0.00 Range/Oven Fuel: Electric Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 575.00 Clothes Dryer EF: 3.01 Dishwasher Energy Factor: 0.64 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. © 1985-2012Architectural Energy Corporation, Boulder, Colorado. Registry ID: Rating Number: Certified Energy Rater: Paul Higman Rating Date: 3-27-13 Rating Ordered For: Encore Homes Estimated Annual Energy Cost Confirmed Rating Use MMBtu Cost Percent Heating 48.0 $330 21% Cooling 1.8 $47 3% Hot Water 13.3 $352 23% Lights/Appliances 22.9 $604 39% Photovoltaics -0.0 $-0 -0% Service Charges $204 13% Total $1537 100% This home meets or exceeds the minimum criteria for all of the following: 2006 International Energy Conservation Code 2009 International Energy Conservation Code City of Fort Collins Green Code 2012' " Compliance with criteria for this program is determined by the rater. Digitally signed Masco Home Services Paul by: Paul Higma 2339 Seville Rd DNS GN = Paul Daytona Beach, FL. 32119 Higrrian C = LIE3860-304-220o H i g m a n Date: 2013.03. 27�15:06:41 - 06'00' FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: Building Name: Owner's Name: Property: Address: Builder's Name: Weather Site: File Name: March 27, 2013 Rating No.: 1956 Mackinac Rating Org.: Encore Homes Phone No.: 1956 Mackinac Rater's Name Fort Collins, CO 80524 Rater's No.: Encore Homes LLC Ft. Collins, CO Rating Type: Encore Homes 1956 Mackinac-Sheldon-final.blg Rating Date: Thermal Concepts 970-223-7090 Paul Higman 6784592 Confirmed Rating 3-27-13 Annual Energy Cost($) FC 2012 As Designed Heating: 411 384 Cooling: 78 61 Water Heating: 352 352 SubTotal - Used to Determine Compliance: 841 796 Lights & Appliances: 612 615 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1657 1614 " Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.332 Home Infiltration (Section 402.4.2): Duct Leakage (Section 403.2.2): PASSES PASSES This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 5.4%. Name: Paul Higman Organization: Thermal Concepts Signature: Date: March 27, 2013 Paul Digitally -signed by. Paul - Design energy cost is based on the following systems: Higman Heating: Fuel -fired air distribution, 64.0 kBtuh, 95.0AFUE. DN::CN = Paul Higman C = Cooling: Air conditioner, 24.0 kBtuh, 13.0 SEER. AS/ Water Heating: Conventional, Elec, 0.95 EF. Higman )IFDate: 2013.03.27 15:06:15 - Window -to -Floor Area Ratio: 0.12 0 11 Blower door test: Htg: 1187 Clg: 1187 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. ©1985-2012Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT 1956 Mackinac Page 2 equal to those in the design home as specified in the 2009 IECC. These standards are,subjectto change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. ©1985-2012Architectural Energy Corporation, Boulder, Colorado.