Loading...
HomeMy WebLinkAbout427 Bow Creek Ln - Disclosures/Air Sealing - 03/25/2013Date of Test: 3-25-13 Customer: Journey Homes Greeley, CO 80634 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: 4. Test Settings: BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Test File: Journey Homes 427 Bow Creek -BD Technician: Paul Higman Project Number: Building Address: 427 Bow Creek Fort Collins, CO 80525 1424 CFM50 (+/- 0.4 %) 3.35 ACH50 0.5596 CFM50/ft2 floor area 170.0 in2 ( +/- 1.4 %) Canadian EgLA @ 10 Pa 98.3 in2 (+/- 2.3 %) LBL ELA @ 4 Pa Flow Coefficient (C) = 159.5 ( +/- 3.7 %) Exponent (n) = 0.560 ( +/- 0.010 ) Correlation Coefficient = 0.99904 Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 97.4 CFM 0.23 ACH 2. Estimated Design Infiltration Rate: Winter: 166.0 CFM Summer: 93.2 CFM 0.39 ACH 0.22 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3-25-13 Test File: Journey Homes 427 Bow Creek -BD Building Information Location Climate Information Volume 25536 Surface Area Floor Area 2544 Height 16 # of Bedrooms 3 # of Occupants Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6020 Cooling Degree Days 287 Design Winter Wind Speed 9.0 mph Design Summer Wind Speed 7.0 mph Design Winter Temp Diff 69 deg F Design Summer Temp Diff 16 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3-25-13 Test File: Journey Homes 427 Bow Creek -BD Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) 67.0 36.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -1.9 n/a n/a -55.5 -53.9 71.3 -50.2 -48.6 64.7 -45.2 -43.6 57.3 -40.1 -38.5 48.1 -35.3 -33.6 42.6 -30.9 -29.3 35.1 -25.2 -23.6 259.9 -20.3 -18.7 208.4 -1.4 n/a n/a None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 1522 1477 -0.5 RingA 1452 1409 0.6 RingA 1368 1327 0.7 Ring A 1256 1218 -0.9 Ring A 1184 1149 0.7 Ring A 1078 1046 -0.8 RingA 954 925 -0.9 Ring B 855 829 1.2 Ring B Deviations from Standard CGSB - Test Parameters BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 3-25-13 Test File: Journey Homes 427 Bow Creek -BD Comments House wrt Garage = 46.2pa House wrt Mech room = Electric water heat