HomeMy WebLinkAbout827 Ridge Runner Dr - Applications/Single Family New - 02/13/2013City of COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES
Fort Collins 281 N. College Ave. • Fort Collins, CO 80524 • Phone: 970-416-2740
www.fcgov.com/building
BUILDING PERMIT APPLICATION
APPLICATION NUMBER t / )</ V0 (0A APPLICATION DATE ' I ✓ - 13
Job Site Address S Z-7 /2C��. !L„ ,— T�.r.� Unit # N/A
PROPERTY OWNER INFO: (All owner Information is required - it is not optional) Phone # 303-488-0061
Last name D. R. HORTON, INC. First Name Middle
Street Address 9555 S. KINGSTON CT., SUITE 200 city ENGLEWOOD State CO Zip 80112
CONTRACTOR INFO: Company Name D. R. HORTON, INC. Contractor Phone # 303-488-0061
Lic Holder Name JOSHUA VICARS City of Fort Collins License # D-590 Supervisor Cert # 3035-D1
Mailing Address 9555 S. KINGSTON CT., SUITE 200 City ENGLEWOOD State CO Zip 80112
LEGAL INFO:
Subdivision/PUDTRAIL HEAD Filing # N/A Lot # 7 Block # S Lot Sq Ft 5_7'7-`I S-�
CONSTRUCTION INFO: Total Building Sq Ft (not including basement) Total Garage Sq Ft Q'1 % 5-(
Residential Sq Ft /4 D (�, rF Comm'I Sq Ft N/A # of Stories I Bldg Height # Dwelling Units 1
1 st Floor Sq Ft 2nd Floor Sq Ft 3f° Floor Sq Ft N/A Unfiished Bsmt Sq Ft
Finished Bsmt Sq Ft N/A # of Bedrooms 3 # of Full Baths Z % Baths - Y: Baths — # of Fireplaces _4
Air Conditioning: Yes&n Energy info: ( Circle appropriate choice ) 1. ComCheck11 2. ResCheck w/Air Sealing 11
3. ResCheck w/Blower Door ❑4. Simulated Performance Alternative 5. Prescriptive w/Air Sealing 6. Prescriptive w/ Blower Door
City of Fort Collins Stock Plan # ! /`��� List appropriate option #s 1 "t- . S -1
UTILITIES INFO: I -
Water Tap Size 3/4" Sewer Tap Size 4" Metered: Yes W]NoF_1 Temp. Pedestal Yes ✓❑ No
Type of Heat: Fvl Gas Electric Electric Main Breaker Size (Residential only) 0150 Amp or Less 200 Amp 0Other
Value of Construction (including labor, material & profit) $ 1 1-Z,.,,y Q#
Description of
/3-74-. £�Icv,
Contact Name & Phone # of JOBSITE SUPERVISOR: SHANE SENA 303-720-4616
Subcontractor Info:
Electrical ECI, INC.
Framer K & L
Solar
Peal. F
-7 _
Mechanical FOUR SEASONS - COBB Plumbing JOHNSON & SONS
Roofing CAMPBELL BEARD Concrete FALCON CONCRETE Fireplace AMI
Other
Other
Other
Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements
contained herein and City
ofof—Fort Collins ordinances and state laws regulating building construction.
Applicant Signature /i/ G Print Name CnKA'/frGl4°' Phone 303-754-322i�.
Distribution: White -Office Yellow -Applicant Pink -VWM/Stormwater
THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE
pity, <7f 31N&6o7ment
updated 1-31-2012
wort Collin & Transportation Services
"- Community Development & Neighborhood Services
2012 FORT COLLINS RESIDENTIAL ENERGY CODE COMPLIANCE FORM
FORM 1 - NON -ELECTRIC HEAT (If using elec heat form 3 must be used), use this form
foj
single family houses, duplex, townhouses, or multi -family up to 3 stories.
Permit Number:
Address: R 2-7 ►21 J v�r
DIRECTIONS: Place a check next to Prescriptive, UA, or SPA indicating the path chosen. An air
tightness Blower Door Test is required and must pass a 4 ACH leakage max.
BUILDING ENVELOPE
Wood frame wall insul r-value
Metal frame wall insul r-value
Crawl space wall
Roof insulation in attic
Roof rafter insulation
Walls below grade
Wood floor over un-cond
Slab on grade floor, unheat
Windows
for house, 2009 IRC, section N1102.1, climate zone S.
INSULATION R-VALUE
R-20 or 13+5ci
R-13+9ci or R-19+8
R-13 or R-10ci
R-38
R-30
R-13 / R-10ci
R-30
R-101 24" DEEP
U-.35
I I(B)TOTAL UA ALTERNATIVE (ResCheck), 2009 IRC, SECTION N1102.1.3
Submit a passing UA calculation (i.e. ResCheck) using 2009 IRC/IECC. The rating must be submitted at time of
application and must include address of residence; name of individual completing the rating form; name & version
of software tool (i.e. ResCheck).
(C)SIMULATED PERFORMANCE ALTERNATIVE, 2009 IECC, SECTION 405
An energy rating system must be utilized using approved computer software tool such as the new modified Fort
Collins version of RemRate. A preliminary rating passing the 2009 IECC must be submitted at time of application.
Rating must include Address, Name of individual completing the rating,& Name & version of software tool. Final
ratino reouires a blower door test. Final passing rating must be submitted for certificate of occupancy.
SIGN: I
DATE:
30
CONTRACTOR: DR kv,1v^
PHONE:
3o3-499-0o6