Loading...
HomeMy WebLinkAbout2308 Trestle Rd - Disclosures/Final Energy - 03/15/2013loot, 2308 Trestle Uniform Energy Rating System Ft. Collins, CO 80525 5 Stars Plus Confirmed Rating Energy Efficient 1 Star 1 1 Star Plus 1 2 Stars 12 Stars Plus 1 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less HERS Index: General Information Conditioned Area: 3245 sq. ft. HouseType: Single-family detached Conditioned Volume: 29241 cubic ft. Foundation: Conditioned basement Bedrooms: 3 Mechanical Systems Features Heating: Fuel -fired air distribution, Natural gas, 95.0AFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Water Heating: Conventional, Natural gas, 0.58 EF, 50.0 Gal. Duct Leakage to Outside: 67.00 CFM. Ventilation System: Exhaust Only: 76 cfm, 24.0 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building Shell Features Ceiling Flat: R-38 Exposed Floor: R-38 Vaulted Ceiling: NA Window Type: U:0.35, SHGC:0.31 Above Grade Walls: R-15, R-23 Infiltration: Foundation Walls: R-11.0 Rate: Htg: 1433 Clg: 1433 CFM50 Slab: R-0.0 Edge, R-0.0 Under Method: Blower door test Lights and Appliance Features Percent Interior Lighting: 10.00 Range/Oven Fuel: Electric Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 575.00 Clothes Dryer EF: 3.01 Dishwasher Energy Factor: 0.64 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. C 1985-2012 Architectural Energy Corporation, Boulder, Colorado. Registry ID: Rating Number: Certified Energy Rater: Rating Date: Rating Ordered For: i Paul Higman 3-15-13 Bartran Consrtuction o Estimated Annual Energy Cost Confirmed Rating Use MMBtu Cost Percent Heating 66.5 $459 27% Cooling 2.2 $57 3% Hot Water 21.2 $138 8% Lights/Appliances 32.1 $847 50% Photovoltaics -0.0 $-0 -0% Service Charges $204 12% Total $1705 100% This home meets or exceeds the minimum criteria for all of the following: 2006 International Energy Conservation Code 2009 International Energy Conservation Code City of Fort Collins Green Code 2012' " Compliance with criteria for this program is determined by the rater. Digitally signed Masco Home Services Pau I by: Paul Higman 2339 Beville Rd iDN: CN = Paul Daytona Beach, FL. 32119 Higman C = US 3860-304-2200 H i g M a n'Date: 2013.03. \,15,15 5:18:45 - 06'00' ®3 FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: March 15, 2013 Rating No.: Building Name: 2308 Trestle Rating Org.: Allied Insulation Owners Name: Bartran Consrruction Phone No.: 970-223-7090 Property: 2308 Trestle Raters Name: Paul Higman Address: Ft Collins, CO 80525 Raters No.: 6784592 Builders Name: Bartran Construction Weather Site: Ft Collins, CO Rating Type: Confirmed Rating File Name: Bartran Homes 2308 Trestle -Res 3-final.blg Rating Date: 3-15-13 Annual Energy Cost ($) FC 2012 As Designed Heating: 559 537 Cooling: 107 75 Water Heating: 136 137 SubTotal - Used to Determine Compliance: 803 748 Lights &Appliances: 850 847 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1857 1799 ' Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.350 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 6.8%. Name: Paul Higman Signature: Organization: Allied Insulation Date: March 15, 2013 * Design energy cost is based on the following systems: 1 a U I Hign?an Heating: Fuel -fired air distribution, 88.0 kBtuh, 95.OAFUE. . DN:ICN = Paul Higman C = US Cooling: Air conditioner, 36.0 kBtuh, 13.0 SEER. H i g �"Y'� a n JDate: 2013.03.15 15:18:22 Water Heating: Conventional, Gas, 0.58 EF. ` ' 0600' Window-to-FloorArea Ratio: 0.12 0.3 Blower door test Htg: 1433 Clg: 1433 CFM50 1 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost Furthermore, the standard reference design HVAC system efficiencies are set REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE- NON-ELECTRIGHEAT 2308 Trestle Page 2 equal to those in the design home as specified in the 2009 IECC. These standards are subject to change,and software updates should be obtained periodically to ensure the compliance calculations reflectcurrentfederal minimum standards. . REMIRate-Residerrtial Er�ergy Analysis and Rating Software v12.97 This information dces not constitute any warranty of energy cost or savings. �1985-2012 Architectural Energy Corporalion,Boulder,Colorado.