HomeMy WebLinkAbout2308 Trestle Rd - Disclosures/Final Energy - 03/15/2013loot,
2308 Trestle
Uniform Energy Rating System
Ft. Collins, CO 80525
5 Stars Plus
Confirmed Rating
Energy Efficient
1 Star
1 1 Star Plus
1 2 Stars
12 Stars Plus
1 3 Stars
3 Stars Plus
4 Stars
4 Stars Plus
5 Stars
5 Stars Plus
500-401
400-301
300-251
250-201
200-151
150-101
100-91
90-86
85-71
70 or Less
HERS Index:
General Information
Conditioned Area: 3245 sq. ft. HouseType: Single-family detached
Conditioned Volume: 29241 cubic ft. Foundation: Conditioned basement
Bedrooms: 3
Mechanical Systems Features
Heating: Fuel -fired air distribution, Natural gas, 95.0AFUE.
Cooling: Air conditioner, Electric, 13.0 SEER.
Water Heating: Conventional, Natural gas, 0.58 EF, 50.0 Gal.
Duct Leakage to Outside: 67.00 CFM.
Ventilation System: Exhaust Only: 76 cfm, 24.0 watts.
Programmable Thermostat: Heating: Yes Cooling: Yes
Building Shell Features
Ceiling Flat: R-38 Exposed Floor: R-38
Vaulted Ceiling: NA Window Type: U:0.35, SHGC:0.31
Above Grade Walls: R-15, R-23 Infiltration:
Foundation Walls: R-11.0 Rate: Htg: 1433 Clg: 1433 CFM50
Slab: R-0.0 Edge, R-0.0 Under Method: Blower door test
Lights and Appliance Features
Percent Interior Lighting: 10.00 Range/Oven Fuel: Electric
Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric
Refrigerator (kWh/yr): 575.00 Clothes Dryer EF: 3.01
Dishwasher Energy Factor: 0.64 Ceiling Fan (cfm/Watt): 0.00
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
C 1985-2012 Architectural Energy Corporation, Boulder, Colorado.
Registry ID:
Rating Number:
Certified Energy Rater:
Rating Date:
Rating Ordered For:
i
Paul Higman
3-15-13
Bartran Consrtuction
o
Estimated Annual Energy Cost
Confirmed Rating
Use
MMBtu
Cost
Percent
Heating
66.5
$459
27%
Cooling
2.2
$57
3%
Hot Water
21.2
$138
8%
Lights/Appliances
32.1
$847
50%
Photovoltaics
-0.0
$-0
-0%
Service Charges
$204
12%
Total
$1705
100%
This home meets or exceeds the minimum
criteria for all of the following:
2006 International Energy Conservation Code
2009 International Energy Conservation Code
City of Fort Collins Green Code 2012'
" Compliance with criteria for this program is
determined by the rater.
Digitally signed
Masco Home Services Pau I by: Paul Higman
2339 Beville Rd iDN: CN = Paul
Daytona Beach, FL. 32119 Higman C = US
3860-304-2200 H i g M a n'Date: 2013.03.
\,15,15 5:18:45 -
06'00'
®3
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
Date: March 15, 2013
Rating No.:
Building Name: 2308 Trestle
Rating Org.:
Allied Insulation
Owners Name: Bartran Consrruction
Phone No.:
970-223-7090
Property: 2308 Trestle
Raters Name:
Paul Higman
Address: Ft Collins, CO 80525
Raters No.:
6784592
Builders Name: Bartran Construction
Weather Site: Ft Collins, CO
Rating Type:
Confirmed Rating
File Name: Bartran Homes 2308 Trestle -Res 3-final.blg
Rating Date:
3-15-13
Annual Energy Cost ($)
FC 2012 As Designed
Heating:
559 537
Cooling:
107 75
Water Heating:
136 137
SubTotal - Used to Determine Compliance:
803 748
Lights &Appliances:
850 847
Photovoltaics:
-0 -0
Service Charge:
204 204
Total:
1857 1799 '
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower): 0.400 0.350
Home Infiltration (Section 402.4.2): PASSES
Duct Leakage (Section 403.2.2): PASSES
This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy
Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 6.8%.
Name: Paul Higman Signature:
Organization: Allied Insulation Date: March 15, 2013
* Design energy cost is based on the following systems: 1 a U I Hign?an
Heating: Fuel -fired air distribution, 88.0 kBtuh, 95.OAFUE. . DN:ICN = Paul Higman C = US
Cooling: Air conditioner, 36.0 kBtuh, 13.0 SEER. H i g �"Y'� a n JDate: 2013.03.15 15:18:22
Water Heating: Conventional, Gas, 0.58 EF. ` ' 0600'
Window-to-FloorArea Ratio: 0.12 0.3
Blower door test Htg: 1433 Clg: 1433 CFM50 1
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been
changed
prior to calculating annual energy cost Furthermore, the standard reference design HVAC system efficiencies
are set
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
01985-2012 Architectural Energy Corporation, Boulder, Colorado.
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE- NON-ELECTRIGHEAT
2308 Trestle Page 2
equal to those in the design home as specified in the 2009 IECC. These standards are subject to change,and
software
updates should be obtained periodically to ensure the compliance calculations reflectcurrentfederal minimum
standards.
.
REMIRate-Residerrtial Er�ergy Analysis and Rating Software v12.97
This information dces not constitute any warranty of energy cost or savings.
�1985-2012 Architectural Energy Corporalion,Boulder,Colorado.