Loading...
HomeMy WebLinkAbout508 San Juan Dr - Disclosures/Air Sealing - 03/03/2013BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Phone: 970-223-7090 Date of Test: 3-3-13 Technician: Paul Higman Test File: Journey Homes 508 San Juan -BD Customer: Journey Homes Greeley, CO 80634 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: Infiltration Estimates Building Address: 508 San Juan Fort Collins, CO 80525 1062 CFM (+/- 1.0 %) 3.29 ACH 0.47 CFM per ft2 floor area 101.3 in2 ( +/- 3.4 %) Canadian EgLA @ 10 Pa 51.5in2(+/-5.8%)LBLELA@4Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 68.9 ( +/- 9.3 %) Exponent (n) = 0.699 ( +/- 0.026 ) Correlation Coefficient = 0.99666 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 1. Estimated Average Annual Infiltration Rate: 44.3 CFM 0.14 ACH 2. Estimated Design Infiltration Rate: Winter: 65.2 CFM 0.20 ACH Summer: 38.8 CFM 0.12 ACH 3. Recommended Whole Building Mechanical 52.7 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 3-3-13 Test File: Journey Homes 508 San Juan -BD Building Conditions Inside Temperature: Outside Temperature: # of Stories Wind Shield: # of Occupants 75 deg F Heating Fuel: 42 deg F Heating Fuel Cost: 1.0 Heating Efficiency: Heating Degree Days: M Cooling Fuel Cost: Cooling SEER: Cooling Degree Days: # of Bedrooms: 3.0 Volume: 19355 ft3 Surface Area: Floor Area: 2265 ft2 Design Winter Wind Speed: 9.0 mph Design Summer Wind Speed: 7.0 mph Comments House wrt Garage =-47.6pa House wrt Mech room = Electric water heater Ventilation Weather Factor: Energy Climate Factor: Design Winter Temp Diff: Design Summer Temp Diff: Gas 6020 287 0.87 17.0 69 deg F 16 deg F BUILDING LEAKAGE TEST Page 3 Date of Test: 3-3-13 Test File: Journey Homes 508 San Juan -BD Data Points: Data Entered Manually Nominal Temperature Building Fan.Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -0.9 n/a +/- 0.00 -50.4 35.5 1084 1050 -0.5 Ring A -45.2 30.7 1009 977 0.0 Ring A -40.1 27.2 952 922 2.8 Ring A -35.2 194.4 826 800 -2.1 Ring B -29.8 155.3 739 716 -1.3 Ring B -25.3 123.6 660 639 -0.8 Ring B -20.1 93.2 574 556 1.9 Ring B -0.7 n/a +/- 0.00