Loading...
HomeMy WebLinkAbout2612 Forecastle Dr - Disclosures/Air Sealing - 02/05/2013Date of Test: 2-5-13 Customer: Journey Homes Greeley, CO 80634 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: 4. Test Settings: BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Test File: Journey Homes 2612 Forecastle -BD Technician: Paul Higman Project Number: Building Address: 2612 Forecastle Fort Collins, CO 80524 1137 CFM50 (+/- 0.5 %) 2.37 ACH50 0.3692 CFM50/ft2 floor area 109.4 in2 ( +/- 2.1 %) Canadian EgLA @ 10 Pa 56.0 in2 (+/- 3.5 %) LBL ELA @ 4 Pa Flow Coefficient (C) = 75.4 ( +/- 5.6 %) Exponent (n) = 0.694 ( +/- 0.015 ) Correlation Coefficient = 0.99860 Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 45.0 CFM 0.09 ACH 2. Estimated Design Infiltration Rate: Winter: 70.8 CFM Summer: 41.8 CFM 0.15 ACH 0.09 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 2-5-13 Test File: Journey Homes 2612 Forecastle -BD Building Information Location Climate Information Volume 28769 Surface Area Floor Area 3080 Height 8 # of Bedrooms 2 # of Occupants Year of Construction 2012 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6020 Cooling Degree Days 287 Design Winter Wind Speed 9.0 mph Design Summer Wind Speed 7.0 mph Design Winter Temp Diff 69 deg F Design Summer Temp Diff 16 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 2-5-13 Test File: Journey Homes 2612 Forecastle-BD Depressurization Test: Environmental Data Indoor Tempereture (°F) Outdoor Temperature (°F) 66.0 55.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.9 n/a n/a -55.0 -54.0 44.7 1212 1199 -0.1 RingA -50.5 -49.5 39.5 1142 1130 -0.0 RingA �5.2 -44.3 34.3 1066 1055 1.0 RingA -40.8 39.8 279.0 988 978 0.6 Ring B -35.8 -34.8 219.8 878 869 -1.9 Ring B -30.8 -29.9 177.2 7S9 781 -1.8 Ring B -24.9 -23.9 140.0 702 695 1.8 Ring B -20.7 -19.8 104.4 607 601 0.6 Ring B -1.0 n/a n/a Deviations from Standard CGSB -Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 2-5-13 Test File: Journey Homes 2612 Forecastle-BD Comments House wrt Garage = -46.8 pa House wrt Mech room = Electric water heat