Loading...
HomeMy WebLinkAbout1008 Burrowing Owl Dr - Disclosures/Final Energy - 02/08/2013BURGESS ������ &41 V-4c*�� Plan # 1625 1008 Burrowing Owl Drive III' ■�■��` III Fort Collins, CO 80525 CONSTRUCTION CONSULTANTS INC. -' SINCE 1986 5 Stars Plus Confirmed Uniform Energy Rating System Energy Efficient 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less HERS Index: 61 Efficient Home Comparison: 39% Better Conditioned Area: 3134 sq. ft. HouseType: Single-family detached Conditioned Volume: 27665 cubic ft. Foundation: More than one type Bedrooms: 2 v aMechanicai;Systems FeaturesIII WIN Heating: Fuel -fired air distribution, Natural gas, 92.0 AFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Water Heating: Conventional, Natural gas, 0.62 EF, 50.O Gal. Duct Leakage to Outside: 0.00 CFM. Ventilation System: Exhaust Only: 54 cfm, 11.3 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Ceiling Flat: Vaulted Ceiling: Above Grade Walls: Foundation Walls: Slab: R-38 R-38 R-15 R-13.0 II Edge, R-0.0 Under Exposed Floor: NA Window Type: Dbi/LoE/Vinyl`** Infiltration: Rate: Htg: 1160 Clg: 1160 CFM50 Method: Blower door test Percent Interior Lighting: 100.00 Range/Oven Fuel: Natural gas _ Percent Garage Lighting: 100.00 Clothes Dryer Fuel: Natural gas Refrigerator (kWh/yr): 775.00 Clothes Dryer EF: 2.67 Dishwasher Energy Factor: 0.68 . Ceiling Fan (cfm/Watt): 70.40 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. C 1985-2012 Architectural Energy Corporation, Boulder, Colorado. Registry ID: 112005336 Rating Number: Worst case scenario DE Certified Energy Rater: Robert Hutchinson Rating Date: 2f7/2013 Rating Ordered For: Shadow Creek 1 Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 49.6 $343 26% Cooling 2.6 $68 5% Hot Water 16.4 $107 8% Lights/Appliances 26.4 $583 45% Photovoltaics -0.0 $-0 -0% Service Charges $204 16% Total $1304 100% This home meets or exceeds the minimum L criteria for all of the following: EPA ENERGY STAR Version 2 Home 2006 International Energy Conservation Code 2009 International Energy Conservation Code '.tgORTGgGF Burgess Construction Consultants o?'Y 101 W. Renner Road, Suite 400 rT Richardson, TX 75082 t {r 214-888-7300 No.° 98-144 214-888-7266 'A9c ttT. �6vm 7479033 eoiTgn°N Certified Energy Rater BURGESS F101 CONSTRUMON CONSULTAM INC, S."11. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: February 08, 2013 Rating No.: Worst case scenario DE Building Name: Plan # 1625 Rating Org.: Burgess Inc. Owner's Name: Shadow Creek Phone No.: 303-300-4527 Property: 1008 Burrowing Owl Drive Raters Name: Robert Hutchinson Address: Fort Collins, CO 80525 Rater's No.: 7479033 Builder's Name: Shadow Creek Homes Weather Site: Denver, CO Rating Type: Confirmed File Name: 1008 Burrowing Owl Drive.blg Rating Date: 2/7/2013 Annual Energy Cost ($) FC 2012 As Designed Heating: 392 406 Cooling: 107 92 Water Heating: 106 106 SubTotal - Used to Determine Compliance: 605 604 Lights &Appliances: 593 583 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1402 1390 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.340 Home Infiltration (Section 402.4.2): Duct Leakage (Section 403.2.2): PASSES PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the rpmurements by 0.2%. Name: Robert Hutchinson Signature: 7479033 Organization: Burgess Inc. Date: F b6 ruary 08, 2013 Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 60.0 kBtuh, 92.0AFUE. Cooling: Air conditioner, 30.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.62 EF. Window -to -Floor Area Ratio: 0.09 REM/Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. ©1985-2012Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Plan # 1625 Blower door test: Htg: 1160 Clg: 1160 CFM50 Page 2 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change; and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. ©1985-2012Architectural Energy Corporation, Boulder, Colorado.