Loading...
HomeMy WebLinkAbout2600 Forecastle Dr - Disclosures/Final Energy - 01/31/2013FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: January 31, 2013 Rating No.: Building Name: 2600 Forecastle Dr Rating Org.: Thermal Concepts Owner's Name: Journey Homes Phone No.: 970-223-7090 Property: 2600 Forecashe Dr Rater's Name: Paul Higman Address: Fort Collins, CO 80524 Rater's No.: 6784592 Builder's Name: Journey Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed Rating File Name: Journey Homes 2600 Forecastle Dr-1540-final.bl Rating Date: 1-31-13 Annual Energy Cost ($) FC 2012 As Designed Heating: 471 473 Cooling: 124 65 Water Heating: 342 338 SubTotal - Used to Determine Compliance: 937 876 Lights &Appliances: 804 793 Photovoltaics: -0 -0 Service Charge: 198 198 Total: 1938 1867 ' Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.342 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 6.5%. Name: Paul Higman Signature: Organization: Thermal Concepts Date: January 31, 2013 ` Design energy cost is based on the following systems: I a u I Heating: Fuel -fired air distribution, 58.0 kBtuh, 92.1 AFUE. Water Heating: Conventional, Elec, 0.95 EF. Higman Cooling:Air conditioner, 14.4 kBtuh, 13.0 SEER. < Window -to -Floor Area Ratio: 0.10 Blower door test: Htg: 1112 Clg: 1112 CFM50 N = Paul Higman C = US 2013.01.31 15:16:22 - In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE- NON-ELECTRIC-HEAT 2600 Forecastle Dr Page 2 equal to those in the design home as specified in the 2009 IECC. These standards are subject to change,and software updates should be obtained periodically to ensure the compliance calcula6ons reflect current federal minimum standards. REM/Rate-Residential Energy Malysis and Rating Soflware v12.97 This i nformation does not constitute any warranty of energy cost or savings. OO 198r2012Architectural EnergyCorporation,Boulder,Colorado.