HomeMy WebLinkAbout2600 Forecastle Dr - Disclosures/Final Energy - 01/31/2013FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
Date: January 31, 2013 Rating No.:
Building Name:
2600 Forecastle Dr
Rating Org.:
Thermal Concepts
Owner's Name:
Journey Homes
Phone No.:
970-223-7090
Property:
2600 Forecashe Dr
Rater's Name:
Paul Higman
Address:
Fort Collins, CO 80524
Rater's No.:
6784592
Builder's Name:
Journey Homes
Weather Site:
Ft. Collins, CO
Rating Type:
Confirmed Rating
File Name:
Journey Homes 2600 Forecastle Dr-1540-final.bl
Rating Date:
1-31-13
Annual Energy Cost ($)
FC 2012
As Designed
Heating:
471
473
Cooling:
124
65
Water Heating:
342
338
SubTotal - Used to Determine Compliance:
937
876
Lights &Appliances:
804
793
Photovoltaics:
-0
-0
Service Charge:
198
198
Total:
1938
1867 '
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower): 0.400 0.342
Home Infiltration (Section 402.4.2): PASSES
Duct Leakage (Section 403.2.2): PASSES
This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy
Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 6.5%.
Name: Paul Higman Signature:
Organization: Thermal Concepts Date: January 31, 2013
` Design energy cost is based on the following systems: I a u I
Heating: Fuel -fired air distribution, 58.0 kBtuh, 92.1 AFUE.
Water Heating: Conventional, Elec, 0.95 EF. Higman
Cooling:Air conditioner, 14.4 kBtuh, 13.0 SEER. <
Window -to -Floor Area Ratio: 0.10
Blower door test: Htg: 1112 Clg: 1112 CFM50
N = Paul Higman C = US
2013.01.31 15:16:22 -
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been
changed
prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies
are set
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
01985-2012 Architectural Energy Corporation, Boulder, Colorado.
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE- NON-ELECTRIC-HEAT
2600 Forecastle Dr Page 2
equal to those in the design home as specified in the 2009 IECC. These standards are subject to change,and
software
updates should be obtained periodically to ensure the compliance calcula6ons reflect current federal minimum
standards.
REM/Rate-Residential Energy Malysis and Rating Soflware v12.97
This i nformation does not constitute any warranty of energy cost or savings.
OO 198r2012Architectural EnergyCorporation,Boulder,Colorado.