HomeMy WebLinkAbout2600 Forecastle Dr - Special Inspections/Engineering - 12/17/2012RMG
ENGINEERS
1601 37t" ST. • EVANS, COLORADO 80620 • 970-330-1071 • FAX 970-330-1252
December 17, 2012
Mr. Jeff Demaske
Journey Homes, LLC
7251 W. 20th St., Bldg L, Ste. 200
Greeley, CO 80634
RE: Footing and Foundation Observation
2600 Forecastle Drive
Maple Hill — 4'" Replat
Fort Collins, Colorado
Dear Jeff:
As requested, RMG Engineers' staff observed the footing and foundation formwork and
reinforcing steel for the above referenced single family residential property and found them to
be in substantial compliance with the design drawings prepared for this structure. The "Wer"
electrical ground system was placed in the footing and meet the requirements of Article
250.52(A)(3) of the 2008 National Electrical Code (NEC). The footings were observed on
December 17, 2012 and the foundation walls were observed on December 18, 2012.
Please give me a call if you have any questions.
Sincerely,
RMG Engineers
Tom Cope, P.E.
North Office Geotech Manager
RMG Project No.: 136178
Etructurol • GeoteINE Chnicnl
EERS
RMG
1601 37th ST. • EVANS, COLORADO 80620 • 970-330-1071 • FAX 970-330-1252
December 17, 2012
Mr. Jeff Demaske
Journey Homes, LLC
7251 W. 20th Street
Building L, Suite 200
Greeley, CO 80634
Re: 2600 Forecastle Drive
Maple Hill - 4th Replat
Dear Jeff:
RMG Engineers (RMG) conducted a foundation excavation review for a single-family
residence under construction at the above -referenced site located in Ft Collins, Colorado.
The footings were excavated to the clayey silty sand, which is similar to those soils described
in the Preliminary Subsurface Exploration Report, Maple Hill Subdivision, prepared by Earth
Engineering Consultants, Inc, EEC project number 1002250 and dated January 19, 2001.
RMG did not encounter groundwater within two feet of the proposed footing elevation. The
soils supporting the footings will be a low expansive material. Based on the soil conditions
encountered within two feet of the footing level, a continuous spread footing may be designed
and constructed in accordance to the above mentioned Preliminary Subsurface Exploration
Report.
Please contact me if you have any questions concerning this matter.
Sincerely,
RMG ENGINEERS
IAPM Pe
Tom Cope, P.E.
Principal
RMG Proj. No. 136178
R
24995 /
'fI (�•(t�) gip ,}y�>+�F`�O
S. rucwr�[-Geoce:olnieol
ENGIMGS
1601 37" ST. • EVANS, COLORADO 80620 a 970-330-1071 • FAX 970-330-1252
December 21, 2012
Mr. Jeff Demaske
Journey Homes, LLC
7251 W. 20th St., Bldg L, Ste. 200
Greeley, CO 80634
Re: Foundation Subsurface Drainage System
2600 Forecastle Drive
Maple Hill — 41h Replat
Fort Collins, Colorado
Dear Jeff:
As requested, RMG Engineers (RMG) staff observed the foundation subsurface drainage pipe
and sump pit perimeter drain system. RMG found it to be complete and in substantial
compliance with the design drawings prepared for this structure at the date of this
observation.
Please give me a call if you have any questions.
Sincerely,
RMG Engineers
1 T�JYW i
2,
}}--
Tom Cope, P.E.
North Office Geotech Manager
RMG Project No.: 136178
JiUF LIMU1'F l C;eoceurtn�cEil
ERMG
1601 37`h ST. • EVANS, COLORADO 80620 • 970-330-1071 • FAX 970-330-1252
December 21, 2012
Mr. Jeff Demaske
Journey Homes, LLC
7251 W. 20th St., Bldg L, Ste. 200
Greeley, CO 80634
RE: Foundation Damp Proofing
2600 Forecastle Drive
Maple Hill —4`h Replat
Fort Collins, Colorado
Dear Jeff:
As requested, RMG Engineers' staff observed the foundation damp proofing and found it to be
complete and in substantial compliance with the design drawings prepared for this structure at
the date of the inspection.
Please give me a call if you have any questions.
Sincerely,
RMG Engineers
Tom Cope, P.E.
North Office Geotech Manager
RMG Project No.: 136178
-,,,"
2499 w
•qyy ����zr J 2 �L 4