Loading...
HomeMy WebLinkAbout408 Toronto St - Disclosures/Final Energy - 01/24/201300 aVI, a10.vex. 408 Toronto Fort. Collins, CO 80524 l� 5 Stars Plus Confirmed Rating Uniform Energy Rating System _ Energy Efficient 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus L500-401 400-301 300.251 250_201_ L200-151 _150-101 J L 100.91_ _ 90-86 _ 85-71 70 or Less HERS Index: 69 General Information Conditioned Area: Conditioned Volume: Bedrooms: Mechanical Systems Features Heating: Cooling: Water Heating: Duct Leakage to Outside: Ventilation System: Programmable Thermostat: Building Shell Features Ceiling Flat: Vaulted Ceiling: Above Grade Walls: Foundation Walls: - r 1542 sq. ft. HouseType: Single-family detached 14820 cubic ft. Foundation: Conditioned crawl space 2 Fuel -fired air distribution, Natural gas, 95.OAFUE. Air conditioner, Electric, 13.0 SEER. Conventional, Electric, 0.95 EF, 50.0 Gal. 32.00 CFM. Exhaust Only: 69 cfm, 24.0 watts. Heating: Yes Cooling: Yes R-38 R-30 R-19,R-15 R-19.0 Slab: None Exposed Floor: Window Type: Infiltration: Rate: Method: R-38 U.0.33,SHGCO.31 Htg: 980 Clg: 980 CFM50 Blower door test Registry ID: { Rating Number: Certified Energy Rater: Paul Higman j Rating Date: 1-24-13 Rating Ordered For: Encore Homes Estimated Annual Energy Cost Confirmed Rating Use MMBtu Cost Percent Heating 44.0 $290 22% Cooling 1.8 $48 4% Hot Water 11.4 $277 21% Lights/Appliances 20.9 $506 38% Photovoltaics -0.0 $-0 -0% Service Charges $198 15% Total $1320 100 % This home meets or exceeds the minimum criteria for all of the following: Lights and Appliance Features , Digitally signed Percent Interior Lighting: 0.00 Range/Oven Fuel: Electric Masco Home Services Pau I by: Paul Higman P Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric 2339 Beville Rd 1 DIN' CN =Paul Refrigerator (kWh/yr): 575.00 Clothes Dryer EF: 3.01 l Daytona Beach, FL. 32119 Higrrian C = US Dishwasher Energy Factor: 0.64 Ceiling Fan (cfm Watt): 0.00 1 3860-304-2200 H i g m a n Date: 2013.01. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. '.10:02:02 - REM/Rate - Residential Energy Analysis and Rating Software v12.97 0624;40, This information does not constitute any warranty of energy cost or savings. © 1985-2012Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: January 24, 2013 Rating No.: Building Name: 408 Toronto Rating Org.: Thermal Concepts Owners Name: Encore Homes Phone No.: 970-223-7090 Property: 408 Toronto Rater's Name: Paul Higman Address: Fort Collins, CO 80524 Rater's No.: 6784592 Builder's Name: Encore Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed Rating File Name: Encore Homes 408 Toronto-Avery-final.blg Rating Date: 1-24-13 Heating: Cooling: Water Heating: SubTotal - Used to Determine Compliance: Lights &Appliances: Photovoltaics: Service Charge: Tota I: Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): Home Infiltration (Section 402.4.2): Duct Leakage (Section 403.2.2): Annual Energy Cost ($) FC 2012 As Designed 345 336 66 62 279 278 690 676 -- 513 517 -0 -0 198 198 1400 1391 0.400 0,330 PASSES PASSES This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 2.0%. Name: Paul Higman Organization: Thermal Concepts Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 64.0 kBtuh, 95.0 AFUE. Cooling:Air conditioner, 30.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Elec, 0.95 EF Window -to -Floor Area Ratio: 0.11 Blower door test: Htg: 980 Clg: 980 CFM50 Signature: Date: January24,2013 Paul Digitally signed by` Paul Higman DNCN = Paul Higman C = US Higman 'Date: 2013.01.24 10:01:33 :f 06'00' In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. © 1985-2012Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT 408 Toronto Page 2 equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate -Residential Energy Analysis and Rating Software 02.97 This information does not constitute any warranty of energy cost or savings. ©1985-2012 Architectural Energy Corporation, Boulder, Colorado.