HomeMy WebLinkAbout857 Ridge Runner Dr - Applications/Single Family New - 12/26/2012City of I COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES
For t Collins 281 N. College Ave. • Fort Collins, CO 80524 • Phone: 970-416-2740
www.fcgov.com/building
BUILDING PERMIT APPLICATION
APPLICATION NUMBER L U0 7 117 APPLICATION DATE
Job Site Address 857 n.d�� 2�,�,,�r C>,
PROPERTY OWNER INFO: (All owner information is required — it is not optional) Phone
Last name D. R. HORTON, INC. First Name
Street
CONTRACTOR INFO: Company Name
Lic Holder Name JOSHUA VICARS
Unit # N/A
303-488-0061
Middle
9555 S. KINGSTON CT., SUITE 200 City ENGLEWOOD State CO Z;p 80112
D. R. HORTON, INC. Contractor Phone # 303-488-0061
City of Fort Collins License # D-590 Supervisor Cert # 3035-D1
Mailing Address 9555 S. KINGSTON CT., SUITE 200 City ENGLEWOOD State CO Zip80112
LEGAL INFO:
Subdivision/PUDTRAIL HEAD Filing # N/A Lot # 1 v Block #__,6 _ Lot Sq Ft .5ZT 51:
CONSTRUCTION INFO: Total Building Sq Ft (not including basement) / / 3 5 s & Total Garage Sq Ft 3 $ SS.
Residential Sq Ft 1 6.Z7 Sf Comm'[ Sq Ft N/A # of Stories 2 Bldg Height 28 11 "t # Dwelling Units 1
1 s' Floor Sq Ft A00 5 20d Floor Sq Ft 1 v Zq s ,47, 30 Floor Sq Ft N/A
Unfiished Bsmt Sq Ft 603 S4'
Finished Bsmt Sq Ft N/A # of Bedrooms 3 # of Full Baths 1 % Baths Y: Baths 1 # of Fireplaces
Air Conditioning: YeGo® Energy info: ( Circle appropriate choice ) 1. ComCheck ❑ 2. ResCheck w/Air Sealing 11
3. ResCheck w/Blower Door ❑ 4. Simulated Performance Alternative 5. Prescriptive w/Air Sealing 6. Prescriptive w/ Blower Doom
City of Fort Collins Stock Plan # ) 8 53 List appropriate option #s 11 4
UTILITIES INFO:
Water Tap Size 3/4" Sewer Tap Size 4° Metered: Yes VNoll Temp. Pedestal YeSZ No
Type of Heat: WIGas1-1 Electric Electric Main Breaker Size (Residential only) Z150 Amp or Less 200 Amp DOther
Value of Construction (including labor, material & profit) $ 11q.1 h Z l -40
Description of Work: p lct I Z 2-0 fill✓ A c. L i k FctU t�pgvaried Pet A-od v
Contact Name & Phone # of JOBSITE SUPERVISOR: SHANE SENA 303-720-4616
Subcontractor Info:
Electrical ECI, INC.
Framer K & L
Solar
Mechanical FOUR SEASONS - COBB
Plumbing JOHNSON & SONS
Roofing CAMPBELL BEARD Concrete FALCON CONCRETE Fireplace AMI
/
Other Other Other
Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements
contained herein and City of Fort Collins ordinances and state laws regulating building construction.
Applicant Signature Print Name KYLE GUNTHER Phone 303-754-3224
Distribution: White —Office Yellow —Applicant Pink —WWWIStormwater
THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE
C
0tv af updated 1-31-2012
Fort Collins Planning, Development & Transportation Services
Community Development & Neighborhood Services
2012 FORT COLLINS RESIDENTIAL ENERGY CODE COMPLIANCE FORM
FORM 1 - NON -ELECTRIC IfEA T (If using elec heat form 3 must be used), use this form
f01
single family houses, duplex. townhouses, or multi -family up to 3 stories.
Permit Number:
Address: 967 R`d c-�'-
DIRECTIONS: Place a check next to Prescriptive, UA, or SPA indicating the path chosen. An air
tightness Blower Door Test is required and must pass a 4 ACH leakage max.
(A)PRESCRIPTIVE compliant
BUILDING ENVELOPE
Wood frame wall insul r-value
Metal frame wall insul r-value
Crawl space wall
Roof insulation in attic
Roof rafter insulation
Walls below grade
Wood floor over un-cond
Slab on grade floor, unheat
Windows
for house, 2009 IRC, section N1102.1, climate zone 5.
INSULATION R-VALUE
R-20 or 13+5ci
R-13+9ci or R-19+8
R-13 or R-10ci
R-38
R-30
R-13 / R-10ci
R-30
R-10, 24" DEEP
U-.35
(B)TOTAL UA ALTERNATIVE (ResCheck), 2009 IRC, SECTION N1102.1.3
Submit a passing UA calculation (i.e. ResCheck) using 2009 IRC/IECC. The rating must be submitted at time of
application and must include address of residence; name of individual completing the rating form; name & version
of software tool (i.e. ResCheck).
(C)SIMULATED PERFORMANCE ALTERNATIVE, 2009 IECC, SECTION 405
An energy rating system must be utilized using approved computer software tool such as the new modified Fort
Collins version of RemRate. A preliminary rating passing the 2009 IECC must be submitted at time of application.
Rating must include Address, Name of individual completing the rating,& Name & version of software tool. Final
ratino requires a blower door test. Final passing rating must be submitted for certificate of occupancy.
SIGN: DATE: rz z/tz
CONTRACTO : DR 001, vw PHONE: 3o3-,w-oo6