Loading...
HomeMy WebLinkAbout821 Campfire Dr - Disclosures/Air Sealing - 12/31/2012BURGESS FEW CONSTRUCTION CONSULTANTS INC. SIFCE 1. AIR LEAKAGE REPORT Date: December 31, 2012 Rating No.: Worst Case Scenario Building Name: 2015 Rating Org.: Burgess Inc. Owner's Name: DR Horton Phone No.: 303-300-4527 Property: 821 Campfire Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO 80524 Rater's No.: 7479033 Builder's Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 821 Campfire Drive Confirmed d.blg Rating Date: 12/31/2012 Whole House Infiltration Duct Leakage Ventilation Blower door test Heating I Cooling Natural ACH: 0.191 0.14 ACH @ 50 Pascals: 3.071 3.07 CFM @ 25 Pascals: 8281 828 CFM @ 50 Pascals: 13001 1300 Eff. Leakage Area: [sq.in] 71.4 71.4 Specific Leakage Area: 0.00016 0.00016 ELAM00 sfshell: [sq.in] 1.031 1.03 Leakage to Outside Units Hvac CFM @ 25 Pascals: 10 CFM25 / CFMfan: 0.0058 CFM25 / CFA: 0.0033 CFM per Std 152: N/A CFM per Std 152 / CFA: N/A CFM @ 50 Pascals: 16 Eff. Leakage Area: [sq.in] 0.86 Thermal Efficiency: N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage: 0.0444 Mechanical: Exhaust Only Sensible Recovery Eff. (%): 0.0 Total Recovery Eff. (%): 0.0 Rate (cfm): 68 Hours/Day: 24.0 Fan Watts. 11.3 Cooling Ventilation: Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable IndoorAir Quality in Low -Rise Residential Buildings, a minimum of 68 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 136 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate - Residential Energy Analysis and Rating Software 03.0 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado. BUILDING LEAKAGE TEST Date of Test: 12/31 /2012 Test File: DR Horton Blower door Customer: DR Horton 7600 E Orchard Rd #350-S Greenwood Village, Colorado 80111 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: Technician: Doug Groff Building Address: 821 Campfire Drive Fort Collins, Colorado 80524 1291 CFM (+/ 0.1 %) 3.05 ACH 0.42 CFM per ft2 floor area 255.4 in2 (+/ 1.1 %) Canadian EgLA @ 10 Pa 196.6 in2 (+/ 1.7 %) LBL ELA @ 4 Pa 0.19 CFM50 per ft2 surface area Flow Coefficient (C) = 493.0 ( +/- 2.6 %) Exponent (n) = 0.246 ( +/- 0.007 ) Correlation Coefficient = 0.99887 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 203.8 CFM 0.48 ACH 2. Estimated Design Infiltration Rate: Winter: 332.3 CFM 0.78 ACH Summer: 188.8 CFM 0.45 ACH 3. Recommended Whole Building Mechanical 0.0 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating 2. Estimated Cost of Air Leakage for Cooling BUILDING LEAKAGE TEST Page 2 Date of Test: 12/31/2012 Test File: DR Horton Blower door Building Conditions Inside Temperature: 66 deg F Heating Fuel: Gas Outside Temperature: 18 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 4.0 Volume: 25437 ft3 Ventilation Weather Factor: 0.87 Surface Area: 6942 ft2 Energy Climate Factor: 17.0 Floor Area: 3043 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments Garage WRT House: 50 Pa @ 50 Pa BUILDING LEAKAGE TEST Page 3 Date of Test: 12/31/2012 Test File: DR Horton Blower door Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -7.5 n/a -65.0 60.5 -60.0 57.4 -55.0 54.5 -50.0 51.6 -45.0 48.8 o vG k P-o F7= �GG� 1405 1339 0.2 Ring A 1370 1306 -0.1 Ring A 1335 1273 -0.2 Ring A 1300 1239 -0.1 Ring A 1265 1206 0.2 Ring A +/- 0.00