HomeMy WebLinkAbout2301 Ballard Ln - Disclosures/Air Sealing - 11/02/2012BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Phone: 970-223-7090 Date of Test: 11-2-12 Test File: Journey Homes 2301 Ballard BD Customer: Journey Homes Greeley, CO 80634 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: Technician: Paul Higman Building Address: 2301 Ballard Fort Collins, CO 80524 833 CFM (+/- 1.6 %) 2.67 ACH 0.38 CFM per ft2 floor area 90.9 in2 (+/- 5.1 %) Canadian EgLA @ 10 Pa 49.9in2(+/-8.6%)LBLELA@4Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 74.9 ( +/- 13.9 %) Exponent (n) = 0.616 ( +/- 0.039 ) Correlation Coefficient = 0.99034 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 52.2 CFM 0.17 ACH 2. Estimated Design Infiltration Rate: Winter: 84.3 CFM 0.27 ACH Summer: 47.9 CFM 0.15 ACH 3. Recommended Whole Building Mechanical 48.3 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 11-2-12 Test File: Journey Homes 2301 Ballard BD Building Conditions Inside Temperature: 70 deg F Heating Fuel: Gas Outside Temperature: 74 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 3.0 Volume: 18741 ft3 Surface Area: Floor Area: 2221 ft2 Design Winter Wind Speed: 9.0 mph Design Summer Wind Speed: 7.0 mph Comments House wrt Garage =-48.2pa House wrt Mech room = Electric water heater Ventilation Weather Factor: 0.87 Energy Climate Factor: 17.0 Design Winter Temp Diff: 69 deg F Design Summer Temp Diff: 16 deg F BUILDING LEAKAGE TEST Page 3 Date of Test: 11-2-12 Test File: Journey Homes 2301 Ballard BD Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.0 n/a +/- 0.00 -50.4 200.1 838 841 2.0 Ring B -45.6 160.8 752 755 -2.5 Ring B -42.6 145.7 716 719 -3.0 Ring B -35.6 128.9 674 677 2.3 Ring B -30.3 106.5 613 615 3.2 Ring B -24.7 75.8 518 520 -0.5 Ring B -20.3 56.3 447 449 -2.4 Ring B -1.5 n/a +/- 0.00