HomeMy WebLinkAbout4820 Prairie Vista Dr - Disclosures/Air Sealing - 11/02/2012lowest'~ (DnergyLogic P Xa 1998-089 F analysis. Insight. answers. AIR LEAKAGE REPORT Date: November 02, 2012 Building Name: PhilGreen Const Owner's Name: PhilGreen Construction, Inc. Property: 4820 Prairie Vista Dr Address: Fort Collins, CO80526 Builder's Name: PhilGreen Construction, Inc. Weather Site: Ft Collins, CO File Name: 4820 Prairie Vista Dr-PhilGreen-REM13.blg Whole House Infiltration Duct Leakage Ventilation Rating No.: 26451 Rating Org.: EnergyLogic, Inc. Phone No.: 1.800.315.0459 Rater's Name: Justin Heldenbrand Rater's No.: 1088900 Rating Type: Confirmed Rating Date: 11/1/12 Blower door test Heating Cooling NaturalACH: 0.11 0.09 ACH @ 50 Pascals: 2.41 2.41 CFM @ 25 Pascals: 698 698 CFM @ 50 Pascals: 1096 1096 Eff. Leakage Area: [sq.in] 60.2 60.2 Specific Leakage Area: 0.000141 0.00014 ELAM 00 sf shell: [sq.in] 0.951 0.95 Leakage to Outside Units Main CFM @ 25 Pascals: 1 CFM25 / CFMfan: 0.0008 CFM25 / CFA: 0.0003 CFM per Std 152: N/A CFM per Std 152 / CFA: N/A CFM @ 50 Pascals: 2 Eff. Leakage Area: [sq.in] 0.09 Thermal Efficiency: N/A Total Duct Leakage Units CFM251CFA Total Duct Leakage: 0.0003 Mechanical: Exhaust Only Sensible Recovery Eff. (%): 0.0 Total Recovery Eff. (%): 0.0 Rate (cfm): 62 Hours/Day: 24.0 Fan Watts: 15.0 Cooling Ventilation: No Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable IndoorAir Quality in Low -Rise Residential Buildings, a minimum of59 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Altematively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 118 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado. (DnergyLogic a �> is9naen F '�rpti analysis. Insight. answers. P COMPONENT LOAD SUMMARY Date: November 02, 2012 Rating No.: 26451 Building Name: PhilGreen Const Rating Org.: EnergyLogic, Inc. Owner's Name: PhilGreen Construction, Inc. Phone No.: 1.800.315.0459 Property: 4820 Prairie Vista Dr Rater's Name: Justin Heldenbrand Address: Fort Collins, CO 80526 Rater's No.: 1088900 Builder's Name: PhilGreen Construction, Inc. Weather Site: Ft Collins, CO Rating Type: Confirmed File Name: 4820 Prairie Vista Dr-PhilGreen-REM13.blg Rating Date: 11/1/12 PhilGreen Coast HEATING SEASON (MMBtulyr) Ceilings/Roofs 4.3 Rim/Band Joists 1.1 Above Grade Walls 13.4 Foundation Walls 12.8 Doors 1.7 Windows/Skylights 8.2 Frame Floors 0.2 Crawl Space/Unht Bsmt 0.0 Slab Floors 4.0 Infiltration 2.8 Mechanical Ventilation 9.5 Ducts 0.0 Active Solar 0.0 Sunspace 0.0 Internal Gains -16.2 Total 41.7 REMIRate -Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado. COMPONENT LOAD SUMMARY PhilGreen Const. Page 2 PhilGreen Const. COOLING SEASON (MMBtutyr) Ceilings/Roofs 0.2 RimBand Joists -0.2 Above Grade Walls -1.0 Foundation Walls -2.0 Doors -0.2 Windows/Skylights 2.2 Frame Floors -0.0 Crawl Space/Unht Bsmt 0.0 Slab Floors -1.8 Infiltration -0.2 Mechanical Ventilation -1.2 Ducts 0.0 Active Solar 0.0 Sunspace 0.0 Internal Gains 11.0 Whole House Ventilation 0.0 Total 6.9 REMIRate - Residential Energy Anatysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado.