HomeMy WebLinkAbout2219 Ballard Ln - Disclosures/Air Sealing - 11/01/2012BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Phone: 970-223-7090 Date of Test: 11-1-12 Test File: Journey Homes 2219 Ballard BD Customer: Journey Homes Greeley, CO 80634 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: Infiltration Estimates Technician: Paul Higman Building Address: 2219 Ballard Fort Collins, CO 80524 1166CFM (+/-0.8%) 2.43 ACH 0.38 CFM per ft2 floor area 115.9 in2 ( +/- 2.7 %) Canadian EgLA @ 10 Pa 60.3 in2 ( +1- 4.5 %) LBL ELA @ 4 Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 83.7 ( +/- 7.3 %) Exponent (n) = 0.673 ( +/- 0.020 ) Correlation Coefficient = 0.99775 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 1. Estimated Average Annual Infiltration Rate: 56.7 CFM 0.12 ACH 2. Estimated Design Infiltration Rate: Winter: 76.4 CFM 0.16 ACH Summer: 45.5 CFM 0.09 ACH 3. Recommended Whole Building Mechanical 53.3 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 11-1-12 Test File: Journey Homes 2219 Ballard BD Building Conditions Inside Temperature: 66 deg F Heating Fuel: Gas Outside Temperature: 68 deg F Heating Fuel Cost: #of Stories 1.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: #of Occupants Cooling SEER: Cooling Degree Days: 287 #of Bedrooms: 2.0 Volume: 28769 ft3 Ventilation Weather Factor: 0.87 Surtace Area: Energy Climate Factor: 17.0 Floor Area: 3080 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments House wrt Garage=-48.2 pa House wrt Mech room = Electric water heater BUILDING LEAKAGE TEST Page 3 Date of Test: 11-1-12 Test File: Journey Homes 2219 Ballard BD Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure(Pa) (Pa) Flow Flow % Error Configuration Std Dev(Pa) -1.1 n/a +/-0.00 -50.9 40.2 1152 1154 -0.5 Ring A -45.2 34.9 1075 1077 0.8 Ring A -40.8 30.0 998 1000 0.5 Ring A -35.8 231.6 901 903 -0.6 Ring B -30.8 181.8 799 801 -2.1 Ring B -24.9 148.1 722 723 2.9 Ring B -20.7 104.4 607 608 -1.3 Ring B -1.5 n/a +/-0.00