HomeMy WebLinkAbout2219 Ballard Ln - Disclosures/Final Energy - 11/13/2012A.
TnVsC0
Contractor
Services
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
Date: November 13, 2012 Rating No.:
Building Name:
2219 Ballard Ln
Rating Org.:
Thermal Concepts
Owner's Name:
Journey Homes
Phone No.:
970-223-7090
Property:
2219 Ballard Ln
Rater's Name:
Paul Higman
Address:
Fort Collins, CO 80524
Raters No.:
6784592
Builder's Name:
Journey Homes
Weather Site:
Ft. Collins, CO
Rating Type:
Confirmed Rating
File Name:
Journey Homes 2219 Ballard Ln R1532 final.blg
Rating Date:
11-1-12
Annual Energy Cost ($)
FC 2012
As Designed
Heating:
500
519
Cooling:
117
56
Water Heating:
291
287
SubTotal - Used to Determine Compliance:
909
861
Lights & Appliances:
783
771
Photovoltaics:
-0
-0
Service Charge:
198
198
Total:
1889
1830 '
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower): 0.400 0.340
Home Infiltration (Section 402.4.2): PASSES
Duct Leakage (Section 403.2.2): PASSES
This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy
Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 5.2%.
Name: Paul Higman
Organization: Thermal Concepts
Design energy cost is based on the following systems:
Heating: Fuel -fired air distribution, 58.0 kBtuh, 92.1 AFUE.
Water Heating: Conventional, Elec, 0.95 EF.
Cooling: Air conditioner, 13.5 kBtuh, 13.0 SEER.
Window -to -Floor Area Ratio: 0.10
Signature:
Date: November 13, 2012
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
01985-2012 Architectural Energy Corporation, Boulder, Colorado.
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE- NON-ELECTRIC-HEAT
2219 Ballard Ln Page 2
Blower door test: Htg: 1166 Clg: 1166 CFM50
In accordance with IECC, building inputs,such as setpoints, infiltration rates,and window shading may have been changed
prior to calculating annual energy cost. Furthermore,the standard reference design HVAC system efficiencies are set
equal to those in the design home as specified in the 2009 IECC. These standards are subject to change,and software
updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Rate-Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
O 1985-2012 Architectural Energy Corporation,Boulder,Colorado.
` �C� Registry ID:
�n� ,/ ��/'��/� � Rating Number:
-,`0, (�`����%' � ' Certified Energy Rater: Paul Higman
A//(/�+ 2219 Ballard Ln
V Rating Date: 11-1-12
�� 2219 Ballard Ln Rating Ordered For: Journey Homes
Contractor Fort Collins,CO 80524
Services
� �. � Estimated Annual Energy Cost
� Confirmed Rating
5 Stars Plus use MMBtu cosc Percent
Confirmed Rating Heating s�.a $aas 2�°io
cooi�n9 0 $o o°ro
Uniform Energy Rating System Energy Efficient
Hot Water 11.5 $285 17%
t Star I t Star Plus I 2 Stars 2 Stars Plus I 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus Lights/Appliances 30.1 $749 45%
500-401 400301 300-251 250-201 200-151 150-101 10491 90-86 85-71 70 or Less photovoltaics -0.0 $-0 -0%
HERS Index: 69 Service Charges $198 12%
�'aeneral Infortr�ation Total $1677 100%
Conditioned Area: 3080 sq.ft. HouseType: Single-family detached
Conditioned Volume: 28769 cubic ft. Foundation: Conditioned basement
This home meets or exceeds the minimum
Bedrooms: 2
Mechanical Systems Features criteria for all of the following:
2009 International Energy Conservation Code
Heating: Fuel-fired air distribution, Natural gas,92.1 AFUE.
Water Heating: Conventional, Electric,0.95 EF,40.0 Gal.
Duct Leakage to Outside: 45.00 CFM.
Ventilation System: Exhaust Only:65 cfm,24.0 watts.
Programmable Thermostat: Heating:Yes Cooling: No
�Bui�l<ling Shell Features
Ceiling Flat: R-38 Exposed Floor: NA
Vaulted Ceiling: R-38 Window Type: U:0.34,SHGC:0.31
Above Grade Walls: R-15 InfilVation:
Foundation Walls: R-11.0, R-0.0, R-13.0 Rate: Htg: 1166 Clg: 1166 CFM50
Slab: R-0.0 Edge, R-0.0 Under Method: Blower door test
I�ighta and Applianee Features
Percent Interior Lighting: 0.00 Range/Oven Fuel: Eledric Masco Home Services
Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric 2339 Beville Rd
Refrigerator(kWh/yr): 575.00 Clothes Dryer EF: 3.01 Daytona Beach, FL.32119
Dishwasher Energy Factor: 0.64 Ceiling Fan(cfmlWatt): 0.00 386-304-2200
The Home Energy Rating Standard DisGosure for this home is available from the rating provider.
REM/Rate-Residential Energy Analysis and Rating Soflware v12.97
This infortnation does not constitute any warranty of energy cost or savings.