Loading...
HomeMy WebLinkAbout1809 Fromme Prairie Way - Disclosures/Final Energy - 10/12/2012R" 5dev &*'47 hilGreen Const. � ne jolt 1809 Fromme Prairie Wayjr Fort Collins, CO 80526 energyLogic www.enorprlegic.com 5 Stars Plus Confirmed Uniform Energy Rating System Energy Efficient 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71. 70 or Less HERS Index: Conditioned Area: 3184 sq. ft. HouseType: Townhouse, inside unit Conditioned Volume: 31641 cubic ft. Foundation: Conditioned basement Bedrooms: 3 1 chanical Systems Features Heating: Fuel -fired air distribution, Natural gas, 92.1 AFUE. Water Heating: Instant water heater, Natural gas, 0.92 EF, 0.0 Gal. Duct Leakage to Outside: 41.00 CFM. Ventilation System: Exhaust Only: 62 cfm, 15.0 watts. Programmable Thermostat: Heating: Yes Cooling: Yes luilding Shell Features Ceiling Flat: R-38 Exposed Floor: R. 43 Vaulted Ceiling: NA Window Type: Low E .321.30 Above Grade Walls: R-20 Infiltration: Foundation Walls: R-10.0, R-0.0 Rate: Htg: 1622 Clg: 1622 CFM50 Slab: R-0.0 Edge. R-0.0 Under Method: Blower door test Percent Interior Lighting: 10.00 Range/Oven Fuel: Natural gas Percent Garage Lighting: 0.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 775.00 Clothes Dryer EF: 2.67 Dishwasher Energy Factor: 0.60 Ceiling Fan (cfm/ Watt): 70.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM[Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. ©1985-2012Architecture] Energy Corporation, Boulder, Colorado. Registry ID: 454786186 Rating Number: 25948 Certified Energy Rater: Justin Heldenbrand Rating Date: 10/12/12 Rating Ordered For: PhilGreen Construction, Inc. Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 37.6 $364 25% Cooling 0 $0 0% Hot Water 14.6 $131 9% Lights/Appliances 35.1 $991 67% Photovoltaics -0.0 $-0 c0% Service Charges $0 0% Total $1485 100% This home meets or exceeds the minimum criteria for all of the following: 2001 International Energy Conservation Code 2003 International Energy Conservation Code 2004 International Energy Conservation Code 2006 International Energy Conservation Code 2009 International Energy Conservation Code Home Energy Rating Provider M°r°ra�i Energy Logic, Inc. x P.O. Box N Berthoud, CO 80513 ?� Phone # 1-800-315-0459 No. s os9 # www.nrglogic_com Justin Heiden b tblIx"� �2012.10.15 09:53:0609:53:06 - Certified Energy Rater HOME ENERGY PERFORMANCE ,OoftTGACt s A i Z No. 84NS Estimated Annual Energy Cost $/yr 1547.1 1500 1000 990.6 500 364.1 ' 17 61.7 130.7 -- 0._ c c c Q c"i in o U d pt O .0 Name: PhilGreen Const. Address: 1809 Fromme Prairie Way Fort Collins, CO 80526 House Type Townhouse, inside unit Cond.Area: 3184 sq. ft. Rating No.: 25948 Issue Date: October 15, 2012 Certification Verified ENERGY RATING CERTIFICATE HERS® Index Q More Energy 150 140 Existing Homes 130 120 Standard New Home 110 100 90 80 70 This Home 60 fi0 50 W 40 30 20 Zero Energy Home 10 Less Energy Annual Estimates*: Electric(kWh): 10377 Natural gas(Therms): 540 CO2 emissions(Tons): 13 Annual Savings**: $1164 * Based on standard operating condition ** Based on a HERS 130 Index Home QnergyLogic analysis. Insight. answers. Estimated Annual Energy Consumption MMBtu/yr 100 ° 89.4 80 60 j 40 37.6 35.1 20 14.6 —1 h, 2.1 0 _ $ 2 C o O J j � Home Energy Rating Provider Energy Logic, Inc. P.O. Box N Certified Rater: Justin Heldenbrand Rater ID: 1088900 Registry ID: 454786186 Rating Date: 10/12/12 Signature: Ae�'yMoaTw� �' M\ 9 No: Justin Helde 2012.10.15 09:53:31 REM/Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. © 1985-2012Architectural Energy Corporation, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RESNET HOME ENERGY RATING Standard Disclosure For home located at: 1809 Fromme Prairie Way City: FortCollins State: CO 1. The Rater or the Rater's employer is receiving a fee for providing the rating on this home. 2. X❑ In addition to the rating, the Rater or Rater's employer has also provided the following consulting services for this home: A. Mechanical system design X❑ B. Moisture control or indoor air quality consulting X❑ C. Performance testing and/or commissioning other than required for the rating itself X❑ D. Training for sales or construction personnel ❑ E. Other (specify below) 3. ❑ The Rater or Rater's employer is: A. The seller of this home or their agent B. The mortgagor for some portion of the financed payments on this home C. An employee, contractor or consultant of the electric and/or natural gas utility serving this home 4. ❑ The Rater or Rater's employer is a supplier or installer of products, which may include: HVAC systems Thermal insulation systems Air sealing of envelope or duct systems Windows or window shading systems Energy efficient appliances Construction (builder, developer, construction contractor, etc.) Other (specify below): Installed in this home by: Rater Employer Rater Employer ❑ Rater Employer 1-1 Rater 1-1 Employer 1-1 Rater ❑ Employer 1-1 Rater ❑ Employer 11 Rater 1-1 Employer OR Is in the business of: Rater Employer Rater Employer Rater Employer 1-1 Rater Employer ❑ Rater Employer 0 Rater ❑ Employer Rater ❑ Employer I attestthatthe above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). The national rating quality control provisions of the rating standard are contained in Chapter One 4.C.8 of the standard and are posted at http:/twww.natresnetorg/accred/Standards.pdf. This home may have been verified under the provisions of Chapter Six, Section 603,'Technical Requirements for Sampling" of the Standard. Justin Heldenbrand Rater's Printed -Name __ -`- _ Justin Heldenbrand 2012.10.15 09:53:59-0600' Raters Signature 1088900 Certification # October 15, 2012 Date RESNET Form 0300-2 energyLogic a wotiwsasc till analysis. Insight. answers. �tWrw�'P` SUMMARY OF SELECTED REPORTS File Name: 1809 Fromme Prairie Way-PhilGreen-REM 13 ENERGYANALYSIS Date: October 15, 2012 Air Leakage Report Displays infiltration in all available units (regardless of the user input). Displays duct leakage in all available units if other than the qualitative default is selected. Also displays the building ventilation information. Component Load Summary Presents the heating and cooling load of the building on a component basis. 2006 EPAct Tax Credit The report indicates whether the home qualifies for tax credits under Section 1332, Credit for Construction of New Energy Efficient Homes, of the Energy PolicyAct of 2205. CODE COMPLIANCE 2006 IECC Certificate 2006 International Energy Conservation Code Certificate 2006 IECC Compliance Certificate Labels Provides a brief description of the energy features in a building for 2006 IECC Compliance. It is meant to be printed for the electrical distribution panel. IECC Consumption Compliance Report The report compares the total annual energy cost for the building design to a prescriptive version of the same building. This type of compliance allows additional flexibility in complying with IECC. The impacts of high efficiency heating and cooling systems, reduced infiltration and other performance features are considered for compliance. 2009 IECC Certificate 2009 International Energy Conservation Code Certificate 2009 IECC Compliance Certificate Labels Provides a brief description of the energy features in a building for 2009 IECC Compliance. It is meant to be printed for the electrical distribution panel. IECC Consumption Compliance Report The report compares the total annual energy cost for the building design to a prescriptive version of the same building. This type of compliance allows additional flexibility in complying with IECC. The impacts of high efficiency heating and cooling systems, reduced infiltration and other performance features are considered for compliance. Fort Collins Consumption Compliance Report The report compares the total annual energy cost for the building design to a prescriptive version of the same building. This type of compliance allows additional flexibility in complying with IECC. The impacts of high efficiency heating and cooling systems, reduced infiltration and other performance features are considered for compliance. REM/Rate - Residential Energy Analysis and Rating Software 03.0 This information does not constitute any warranty of energy cost or savings. 0 1985-2012 Architectural Energy Corporation, Boulder, Colorado. SUMMARY OF SELECTED REPORTS PhilGreen Const. RATING Page 2 Home Energy Rating Certificate (HERC) Provides a home energy rating index and annual energy cost estimate in accordance with the "Mortgage Industry National Home Energy Rating Systems Standards" as promulgated by the Residential Energy Services Network (RESNET). HERC - Home Performance Provides a home energy rating index and performance on an existing home in accordance with the "Mortgage Industry National Home Energy Rating Systems Standards" as promulgated by the Residential Energy Services Network (RESNET). RESNET Standard Disclosure To be completed for each home that receives a Home Energy Rating. Its purpose is to disclose the Rater's affiliation with the home at the time the final rating is issued. REM/Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. 01985-2012 Archdectural Energy Corporation, Boulder, Colorado. *- nergyLo gic O, Ma1YB8089 analysis. Insight. answers. 2005 EPACT ENERGY EFFICIENT HOME TAX CREDIT Date: October 15, 2012 Rating No.: 25948 Building Name: PhilGreen Const Rating Org.: Owner's Name: PhilGreen Construction, Inc. Phone No.: Property: 1809 Fromme Prairie Way Rater's Name: Address: Fort Collins, CO80526 Raters No.: Builder's Name: PhilGreen Construction, Inc. Weather Site: Ft. Collins, CO Rating Type: File Name: 1809 Fromme Prairie Way-PhilGreen-REM 13.bli Rating Data: Normalized, Modified End -Use Loads (MMBtu/year) 2004 IECC 50% Target As Designed Heating: 24.1 21.2 Cooling: 8.1 5.9 Total: 32.2 27.1 EnergyLogic, Inc. 1.800.315.0459 Justin Heldenbrand 1088900 Confirmed 10/12/12 Envelope Loads (MMBtu/year) 2004 IECC 90% Target As Designed Heating: 43.4 29.7 Cooling: 14.5 7.4 Total: 57.9 37.1 This home MEETS the requirements for the residential energy efficiency tax credits under Section 1332, Credit for Construction of New Energy Efficient Homes, of the Energy Policy Act of 2005. As demonstrated above, this dwelling unit has a projected level of annual heating and cooling energy consumption that is at least 50% below the annual level of heating cooling energy consumption of a reference dwelling in the same dimate zone, and the building envelope components improvements alone aocount for at least 10% of those savings. The projected heating and roofing energy savings above have been calculated in the manner prescribed in Section 2.02 of Notice 2006.27 of the Internal Revenue Service. Field inspections of the dwelling unit performed by the undersigned eligible certifier during and after the completion of construction have confirmed that all features of the home affecting such heating and cooling energy consumption comply with the design specifications provided to the undersigned certifier. Ceiling Flat R-38 Vaulted Ceiling: NA Above Grade Walls: R-20 Foundation Walls: R-10.0, R-0.0 Exposed Floor: R-43 Building Features Slab: R-0.0 Edge, R-0.0 Under Dud: Uninsulated Window: U-Value = 0.320, SHGC = 0.300 Heating: Fuel -fired air distribution, Natural gas, 92.1 AFUE. Cooling N/A Under penalties of perjury, I declare that I have examined this certification, including accompanying documents, and to the best of my knowledge and belief, the facts presented In support of this certification are true, correct, and complete. _ Name: Justin Heldenbrand Signature: Justin 2012.10.15.15 0Heldebrand 09:51:36-06'00' Company: EnergyLogic, Inc. Date: October 15, 2012 Address: PO Box N, Berthoud, CO 80513 REMIRate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado. energyLogic to analysis. insight. answers. �torrwM� 2006 IECC ANNUAL ENERGY COST COMPLIANCE Date: October 15, 2012 Rating No.: 25948 Building Name: PhilGreen Const Rating Org.: EnergyLogic, Inc. Owners Name: PhilGreen Construction, Inc. Phone No.: 1.800.315.0459 Property: 1809 Fromme Prairie Way Rater's Name: Justin Heldenbrand Address: Fort Collins, CO 80526 Rater's No.: 1088900 Builder's Name: PhilGreen Construction, Inc. Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 1809 Fromme Prairie Way-PhilGreen-REM 13.bl( Rating Date: 10/12/12 Annual Energy Cost ($) 2006 IECC As Designed Heating: 619 370 Cooling: 109 64 Water Heating: 182 120 SubTotal - Used to Determine Compliance: 909 554 Lights &Appliances: 1002 991 Photovoltaics: -0 -0 Service Charge: 0 0 Total: 1912 1545 Mandatory Requirements: Duct Insulation R-Value Check (per Section 403.2.1) Minimum Duct Insulation (Design must be equal or higher) 8.0 8.0 Window U-Factor Check (Section 402.6) Window U-Factor (Design must be equal or lower): 0.480 0.318 This home MEETS the annual energy cost requirements of Section 404 of the 2006 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 39.1 %. Name: Justin Heldenbrand Organization: EnergyLogic, Inc. Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 39.0 kBtuh, 92.1 AFUE. Water Heating: Instant water heater, Gas, 0.92 EF. Cooling: Air conditioner, 10.7 kBtuh, 13.0 SEER. Signature: Date: October 15, 2012 REMIRate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. 0 1985-2012 Architectural Energy Corporation, Boulder, Colorado. 2006 IECC ANNUAL ENERGY COST COMPLIANCE PhilGreen Const. Page 2 Window -to -Floor Area Ratio: 0.07 Blower door test: Htg: 1622 Clg: 1622 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set to the "prevailing federal minimum standards" as of January, 2009. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. ©19852012 Architectural Energy Corporation, Boulder, Colorado. 2006 IECC Certificate 1809 Fromme Prairie Way, Fort Collins, CO80526 Building Envelope Insulation Ceiling Flat: R-38 Vaulted Ceiling: NA Above Grade Walls: R-20 Foundation Walls: R-10.0, R-0.0 Exposed Floor: Slab: Infiltration: Duct Duct Leakage to Outside: Window: R-43 R-0.0 Edge, R-0.0 Under Htg: 1622 Clg: 1622 CFM50 Uninsulated 41.00 CFM @ 25 Pascals 0.320 0.300 HEAT: Fuel -fired air distribution, Natural gas, 92.1 AFUE. COOL: N/A DHW: Instant water heater, Natural gas, 0.92 EF, 0.0 Gal. Signature REMR3te- ftSkA rdWEnergy Ma"is andRafkg Software 03.0 e nergyLo gic N Me.,0Y6080 analysis. Insight. answers. 2009 IECC ANNUAL ENERGY COST COMPLIANCE Date: October 15, 2012 , Rating No.: 25948 Building Name: PhilGreen Const. Rating Org.: EnergyLogic, Inc. Owner's Name: PhilGreen Construction, Inc. Phone No.: 1.800.315.0459 Property: 1809 Fromme Prairie Way Rater's Name: Justin Heldenbrand Address: Fort Collins, CO 80526 Rater's No.:. 1088900 Builder's Name: PhilGreen Construction, Inc. Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 1809 Fromme Prairie Way-PhilGreen-REM 13.b1c Rating Date: 10/12/12 Annual Energy Cost ($) 20091ECC As Designed Heating: 653 436 Cooling: 109 78 Water Heating: 181 120 SubTotal - Used to Determine Compliance: 943 634 Lights & Appliances: 1002 991 Photovoltaics: -0 -0 Service Charge: 0 0 Total: 1945 1624 Mandatory Requirements: Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher) 6.0 8.0 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.318 Home Infiltration (Section 402.4.2): PASSES Dud Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5B. In fad, this home surpasses the requirements by 32.8%. Justin Heldenbrand Name: Justin Heldenbrand Signature:a 2012.10.1509:52:09 Organization: EnergyLogic, Inc. Date: October 15, 2012 REM/Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado. 2009 IECC ANNUAL ENERGY COST COMPLIANCE PhilGreen Const. Page 2 Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 39.0 kBtuh, 92.1 AFUE. Water Heating: Instant water heater, Gas, 0.92 EF. Cooling:Air conditioner, 10.7 kBtuh, 13.0 SEER. Window -to -Floor Area Ratio: 0.07 Blower door test Htg: 1622 Clg: 1622 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REMIRats - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado. O l�01�0/10 r�Or'�4r�9�19�191�0/1\9/_'�4/14/=�9/19l\4l\4/�\4/14l\4/14/�\4�\4/�\4 it HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 1809 Fromme Prairie Way, Fort Collins, CO by PhilGreen Construction, Inc. exceeds the minimum requirements for the 2009 International Energy Conservation Code 10/12/12 Building Features Ceiling Flat: R-38 Duct Leakage to Outside: 41.00 CFM @ 25 Pascals Vaulted Ceiling: NA Total Duct Leakage: 87.00 CFM @ 25 Pascals Above Grade Walls: R-20 Infiltration: Htg: 1622 Clg: 1622 CFM50 Foundation Walls: R-10.0, R-0.0 Window: U-Value = 0.320, SHGC = 0.300 Exposed Floor: R-43 Heating: Fuel -fired air distribution, Natural gas, 92.1 AFUE. Slab: R-0.0 Edge, R-0.0 Under Cooling N/A Duct: Uninsulated Water Heating: Instant water heater, Natural gas, 0.92 EF, 0.0 Gal. The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 20091ECC requirements in compliance with Chapter 4 based on Climate Zone 5B and with all mandatory requirements. Justin Heldenbrand Name: Justin Heldenbrand Signature: 2012.10.15 09:52:38 —4-4.-06-no. Organization: EnergyLogic, Inc. Date: October 15, 2012 The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC'j. No version of this software has been reviewed orapproved by ICC or its affiliates. REW/Rate - Resident/al Energy Analysis and Rating Software v13.0 No Text