3102 Chase Dr - Disclosures/Air Sealing - 10/24/2012
e nergyL©gic analysis. Insight. answers. AIR LEAKAGE REPORT Date: October 24, 2012 Rating No.: 26008 Building Name: Habitat for Humanity Rating Org.: EnergyLogic, Inc. Owner's Name: Habitat for Humanity Phone No.: 970.566.6463 1.800.315.0459 Property: 3102 Chase Dr #3 Rater's Name: Justin Heldenbrand Address: Fort Collins, CO 80525 Rater's No.: 1088900 Builder's Name: Habitat for Humanity Weather Site: Ft. Collins, CO Rating Type: Confirmed Rating File Name: 3102 ChaseDr#3-HFH FC-REM13.blg Rating Date: 10/23/12 Whole House Infiltration Duct Leakage Ventilation Blower door test Heating Cooling NaturalACH: 0.17 0.13 ACH @ 50 Pascals: 2.82 2.82 CFM @ 25 Pascals: 439 439 CFM @ 50 Pascals: 689 689 Eff.LeakageArea: [sq.in] 37.8 37.8 Specific Leakage Area: 0.00020 0.00020 ELA/100sfshell: [sq.in] 0.88 0.88 Leakage to Outside Units Main CFM @ 25 Pascals: 7 CFM25 / CFMfan: 0.0048 CFM25 / CFA: 0.0052 CFM per Std 152: N/A CFM per Std 152 / CFA: N/A CFM @ 50 Pascals: 11 Elf. Leakage Area: [sq.in] 0.60 Thermal Efficiency: N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage: 0.0570 an 1 Oil ASHRAE 62.2 - 2010 Ventilation Requirements D For this home to comply withASHRAE Standard 62.2 - 2010 Ventilation and Acceptable IndoorAir Quality in Low -Rise Residential Buildings, a minimum of 43 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 87 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate - Residential Energy Analysis and Rating Software 03.0 This information does not constitute any warranty of energy cost or savings. @ 1985-2012Architectural Energy Corporation, Boulder, Colorado. GnergyLogic analysts. Insight. answers. COMPONENT LOAD SUMMARY Date: October 24, 2012 Building Name: Habitat for Humanity Owner's Name: Habitat for Humanity Property: 3102 Chase Dr#3 Address: Fort Collins, CO 80525 Builder's Name: Habitat for Humanity Weather Site: Ft. Collins, CO File Name: 3102 ChaseDr#3-HFH FC-REM13.blg Habitat for Humanity HEATING SEASON (MMBtu/yr) Ceilings/Roofs 7.0 Rim/Band Joists 1.5 Above Grade Walls 7.7 Foundation Walls 4.9 Doors 0.8 Windows/Skylights 6.5 Frame Floors 0.0 Crawl Space/Unht Bsmt 0.0 Slab Floors 4.9 Infiltration 2.7 Mechanical Ventilation 6.6 Ducts 0.6 Active Solar 0.0 Sunspace 0.0 Internal Gains -11.8 Total 31.2 Habitat for Humanity Rating No.: 26008 Rating Org.: EnergyLogic, Inc. Phone No.: 970.566.6463 1.800.315.0459 Rater's Name: Justin Heldenbrand Rater's No.: 1088900 Rating Type: Confirmed Rating Rating Date: 10/23/12 REM/Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. I] {I 11 �I q; ©1985-2012 Architectural Energy Corporation, Boulder, Colorado. y p 11 `\ d7