HomeMy WebLinkAbout335 Toronto St - Disclosures/Final Energy - 09/07/2012990" Ra&ffl &W.4047
A(/UW 335 Toronto
�A V' 335 Toronto
Contractor
Services Fort Collins, CO 80524
Uniform Energy Rating System
O W5 Stars Plus
�+
Confirmed Rating
Energy Efficient
1 Star
1 Star Plus
2 Stars
2 Stars Plus
3 Stars
3 Stars Plus
4 Stars
4 Stars Plus
5 Stars
5 Stars Plus
500-401
400-301
300-251
250-201
200-151
150-101
100-91
90-86
85-71
70 or Less
HERS Index:
General Information
Conditioned Area:
1242 sq. ft. HouseType: Single-family detached
Conditioned Volume:
13584 cubic ft. Foundation: Conditioned crawl space
Bedrooms:
2
Mechanical Systems Features
Heating:
Fuel -fired air distribution, Natural gas, 95.0 AFUE.
Water Heating:
Conventional, Electric, 0.95 EF, 50.0 Gal.
Duct Leakage to Outside: 32.00 CFM.
Ventilation System: Exhaust Only: 62 dim, 24.0 watts.
Programmable Thermostat: Heating: Yes Cooling: No
Building Shell Features
Ceiling Flat: R-38 Exposed Floor: NA
Vaulted Ceiling: NA Window Type: U.0.33,SHGC0.31
Above Grade Walls: R-19 Infiltration:
Foundation Walls: R-19.0 Rate: Htg: 872 Clg: 872 CFM50
Slab: None Method: Blower door test
Lights and Appliance Features
Percent Interior Lighting: 0.00 Range/Oven Fuel: Electric
Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric
Refrigerator (kWh/yr): 575.00 Clothes Dryer EF: 3.01
Dishwasher Energy Factor: 0.64 Ceiling Fan (cfm/Watt): 0.00
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
REM/Rate - Residential Energy Analysis and Rating Software 02.97
This information does not constitute any warranty of energy cost or savings.
® 1985-2012 Architectural Energy Corporation, Boulder, Colorado.
Registry ID:
Rating Number:
Certified Energy Rater:
Rating Date:
Rating Ordered For:
Paul Higman
9-7-12
Encore Homes
Estimated Annual Energy Cost
Confirmed Rating
Use
MMBtu
Cost
Percent
Heating
35.8
$237
20%
Cooling
0
$0
0%
Hot Water
11.4
$276
24%
Lights/Appliances
19.1
$461
39%
Photovoltaics
-0.0
$-0
-0%
Service Charges
$198
17%
Total
$1171
100%
This home meets or exceeds the minimum
criteria for all of the following:
2006 International Energy Conservation Code
2009 International Energy Conservation Code
�—Digitally signed
///��� / by: Paul Higmen
PauV
ONtCN=Paul
Masco Home Services
C�
Hlgman C = US
Thermal
2339 Beville Road D.
Co
Co Allied
Da tonal Beach, FL. 32119
I
Insulation
Insulation
Date: 2012.09.
386-763-4955 ICjnatU <
g
`^
05 1s:aoss-
05'00'
[///
re not
Reason: I am
verified!
the author of
this document
Certified Energy Rater
A/V\sCo
Contractor
Services
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
Date: September 07, 2012
Rating No.:
Building Name: 335 Toronto
Rating Org.:
Thermal Concepts
Owner's Name: Encore Homes
Phone No.:
970-223-7090
Property: 335 Toronto
Rater's Name:
Paul Higman
Address: Fort Collins, CO 80524
Rater's No.:
6784592
Builder's Name: Encore Homes
Weather Site: Ft. Collins, CO
Rating Type:
Confirmed Rating
File Name: Encore Homes 335 Toronto_Avery_final.blg
Rating Date:
9-7-12
Annual Energy Cost ($)
FC 2012 As Designed
Heating:
303
275
Cooling:
74
44
Water Heating:
278
276
SubTotal - Used to Determine Compliance:
655
596
Lights & Appliances:
466
469
Photovoltaics:
-0
-0
Service Charge:
198
198
Total:
1319
1263 '
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower):
0.400
0.330
Home Infiltration (Section 402.4.2):
PASSES
Duct Leakage (Section 403.2.2):
PASSES
This home MEETS the annual energy cost requirements
and verifications of Section 405 of the 2009 International Energy
Conservation Code, amended by the City of Fort Collins.
In fact, this home surpasses the requirements by 9.1%.
Name: Paul Higman
Signature:
Organization: Thermal Concepts
Design energy cost is based on the following systems:
Heating: Fuel -fired air distribution, 68.0 kBtuh, 95.0 AFUE.
Water Heating: Conventional, Elec, 0.95 EF.
Cooling: Air conditioner, 8.7 kBtuh, 13.0 SEER.
Window -to -Floor Area Ratio: 0.13
Blower door test: Htg: 872 Clg: 872 CFM50
Date: September 07, 2012
u�� Paul
Signature HIg,man
not verified!
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
0 1985-2012 Architectural Energy Corporation, Boulder, Colorado.
Digitally signed by: Paul
Higman
DN: CN = Paul Higman C
= US O = Thermal
Concepts/ Allied
Insulation
Date: 2012.09.07 16:30:
40-05'00'
Reason: I am the author
of this document
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
335 Toronto
Page 2
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed
prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set
equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software
updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
01985-2012 Architectural Energy Corporation, Boulder, Colorado.