HomeMy WebLinkAbout380 Bannock St - Disclosures/Air Sealing - 08/01/2012BUILDING LEAKAGE TEST Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Phone: 970-223-7090 Date of Test: 8-1-12 Technician: Paul Higman Test File: Encore Homes 380 Bannock whitcomb BD Customer: Encore Homes Building Address: 380 Bannock Fort Collins, CO 80524 Windsor, CO 80550 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: Infiltration Estimates 962 CFM (+/- 1.1 %) 3.69 ACH 0.52 CFM per ft2 floor area 78.3 in2 ( +1- 4.4 %) Canadian EgLA @ 10 Pa 36.3 in2 (+/- 7.4 %) LBL ELA @ 4 Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 42.4 ( +/- 11.8 %) Exponent (n) = 0.798 ( +/- 0.032 ) Correlation Coefficient = 0.99674 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 1. Estimated Average Annual Infiltration Rate: 38.3 CFM 0.15 ACH 2. Estimated Design Infiltration Rate: Winter: 61.4 CFM 0.24 ACH Summer: 34.9 CFM 0.13 ACH 3. Recommended Whole Building Mechanical 40.2 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 8-1-12 Test File: Encore Homes 380 Bannock whitcomb BD Building Conditions Inside Temperature: 84 deg F Heating Fuel: Gas Outside Temperature: 94 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 2.0 Volume: 15665 ft3 Ventilation Weather Factor: 0.87 Surface Area: Energy Climate Factor: 17.0 Floor Area: 1843 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments House wrt Garage =-45.5pa House wrt Mech = mechanical room is outside -42pa BUILDING LEAKAGE TEST Page 3 Date of Test: 8-1-12 Test File: Encore Homes 380 Bannock whitcomb BD Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.2 n/a +/- 0.00 -50.4 252.3 940 949 -0.3 Ring B -45.2 214.8 868 876 0.6 Ring B -40.1 172.2 778 785 -0.5 Ring B -35.6 140.0 702 708 -1.0 Ring B -30.5 117.6 644 650 3.2 Ring B -25.5 77.9 525 530 -2.4 Ring B -1.0 n/a +/- 0.00