Loading...
HomeMy WebLinkAbout2451 S Taft Hill Rd - Correspondence/Health Department - 09/06/2006LARIMER DEPARTMENT OF HEALTH AND ENVIRONMENT COUNTY 1525 Blue Spruce Drive Fort Collins, Colorado 80524-2004 General Health (970) 498-6700 Environmental Health (970) 498-6775 Fax (970) 498-6772 September 6, 2006 Safeway, Inc Safeway C-Store 6900 S. Yosemite Ave. Englewood, CO 80112- Wo38q 5 To Whom it May Concern, The plans and specificati s submitted for the construction of the Safeway Convenience Store, to be located at 2451 S. Taft Hill Rd. in Fort Collins, Colorado, have been reviewed by this department. The following items were not clearly specified in the plans or were not in compliance with the Colorado Retail Food Establishment Rules and Regulations. These items must be clearly specified in writing or be modified to be in compliance with the above regulations. The plans are approved at this time. 1. The menu for the proposed facility, submitted with the plans, indicated all food will be prepackaged. Please be advised if the menu expands or is changed to include produce handling, unpackaged foods, or foods that require preparation, additional equipment will be required by the department and an additional review may be necessary. 2. Hot water requirements based on submitted information indicate the facility will require 32.5 gallons of hot water per hour and 7.9 kW. The specifications for the proposed water heater indicate it will provide 49 gallons per hour and 12 kW, the water heater is approved. 3. Please submit information on proposed food handling procedures for the following areas. Please include any Hazard Analysis Critical Control Point (HACCP) plan/food handling procedure manual that details the following: a) Protocols and/or systems that are setup and used to monitor food and equipment temperatures. b) Proposed procedures/methods to thaw frozen foods. c) Policies used to restrict or exclude food workers who are ill. Controls used to manage workers that return to work after being ill. d) Policies used to restrict and manage workers that have cuts or sores on their hands and arms. e) Policies/procedures to minimize bare hand contact with ready to eat foods. 4. If bulk foods such as jerky or candy are to be dispensed provide specification as to what equipment will be used to dispense these foods. Please be advised bulk foods must be dispensed in accordance with 25-4-1301 CRS (copy attached). In general, potentially hazardous foods such as seed sprouts and seafood can not be bulk dispensed. Bulk food dispensers must have self closing lids. Dispensing F 1 mP v utensils must be protected and tethered. Openings on bulk food bins must be at least 30 inches up off the floor. 5. Please be advised all food service equipment must be of commercial design that is certified or classified for sanitation by an American National Standards Institute (ANSI) accredited certification program such as NSF, ETL Sanitation, UL Sanitation, or BISSC Certified. Custom made and used equipment cannot be approved until it is visually inspected. 6. The refrigeration equipment in the operation is limited to merchandising display coolers for prepackaged foods. No hot holding equipment is indicated at this time. Please be advised if the menu expands or is changed to include produce handling, unpackaged foods, foods that require preparation, or hot holding, additional equipment will be required by the department. 7. Please be advised heavy floor mounted equipment such as reach -in coolers and freezers must be mounted on casters to allow for mobility and easy cleaning of the equipment, surrounding surfaces and adjoining equipment. Heavy counter mounted equipment such as soft drink, ice, tea, juice, and coffee dispensers which can not be easily moved for cleaning must be installed on four inch sanitary leas or neativ sealed to counters to facilitate cleanina. 8. Please be advised that no appurtenances, such as syrup lines, carbonators, drop -in cold plates, drain lines or drained bottle holders are permitted in potable ice bins or any unit used to store potable ice. Ice used for beverages must be stored in an approved indirectly drained ice bin. 9. Please be advised pallets, dunnage racks, shelves and other floor racking systems must be installed in a manner that will not inhibit or prevent easy cleaning of floors and surrounding surfaces. Storage shelves located in all food preparation areas, and storage areas must be situated at least six inches off the floor. Metal shelves in the walk-in coolers and freezers must be of an approved metal wire construction. Soft drink carbonators must be provided with six inch legs to permit easy cleaning. 10. Hard to clean spaces or gaps around equipment, counters, utilities and plumbing must be eliminated to provide for easy cleaning. All equipment, cabinets or counters that are not mounted on casters or are not easily moveable must be: a) Spaced in accordance with Section 4-302 A and C of the Rules and Regulations so the surfaces of the floors, walls and exterior surfaces of equipment and cabinets can be easily cleaned; or b) Neatly sealed to adjoining walls, equipment, cabinets or counters. 11. Grocery display refrigeration units and display freezers located at the front of the service areas must be neatly sealed in place to the floors, adjoining equipment and to walls. Toe kicks or kick plates on these units must be removable in order to facilitate cleaning the floors under them. Grocery display shelving units must have easily removable toe kicks or kick plates to facilitate cleaning the floors under them. 12. This operation is not approved for any type of cooking or hot holding of potentially hazardous foods. F Z or 5 13. The facility is not approved for any produce preparation or washing, if produce is to be prepped in the future, an approved stainless steel food preparation sink with a minimum of one 18 inch drain board must be provided. Be advised, this sink must be indirectly drained to sewer. 14. Please be advised the 3-compartment warewashing sink tubs must be large enough to accommodate all equipment used in food preparation and storage. Drain boards must be self -draining and at least 24". 18" drainboards and an overhead .drying rack are approved for this facility only if; a similar sized sink with 24" drainboards will not fit, and the facility does not add menu items which require extensive utensil or equipment washing. 15. Hand washing sinks must be easily accessible in all areas where food is prepared, served or where utensils and equipment is washed. The present location of the hand washing sink in the back work room and restroom is approved. Please be advised addition of open foods requiring preparation, such as hot dogs or nachos will require an additional handsink in the front service area. Hand washing sinks must be provided with hot and cold running water under pressure through a mixing valve, single service hand towels from a dispenser and soap. 16. Please be advised all drains from equipment such as ware washing sinks, food preparation sinks, dish machines, ice machines, ice bins, drink dispensers, drink overflow drains, refrigeration/freezer units not provided with evaporation pans, water heaters, and cold tables holding ice must be directed to a floor drain or floor sink and be properly air gapped. Per discussion with Mark Schmidt on 9/11/06, the 3-compartment sink for this facility will be indirectly drained to a floor sink located under the sink. 17. Please be advised floor sinks must not be installed under equipment or cabinetry where they cannot be cleaned. All floor sinks and floor drains must be installed so they are flush with the finished floor. 18. Please be advised approved, properly installed, backflow devices must be provided on all submerged inlets, hose reels, dish machines, hose bibs, rinse hoses that do not have an air gap, soft drink carbonators and coffee/tea dispensers. Backflow devices on water lines subject to back pressure or continuous pressure must be equipped with backflow preventers that are designed for continuous pressure. 19. It is acknowledged that a grease trap is not to be installed for the facility, if one is to be installed please provide information noting the size and location of the grease trap/interceptor if one is required by the governing wastewater authority. If required the grease trap/interceptor must be installed out of the food preparation areas and the top of the trap must be finished flush with the finished floor to permit easy cleaning around the equipment. 20. The plans do not indicate a separate water outlet will be provided at the mop sink for installation of a chemical dispensing tower. If a chemical dispensing tower is proposed for this operation or will be added in the future, a separate water outlet must be provided; 21. Please. be advised all plumbing, gas, lines, electrical conduit and other service utility lines must be located behind walls, above finished ceilings or below floors f 3 of S in finished rooms and areas. Exposed water pipes, sewer lines, gas lines or electrical conduit running along the surface of the walls, ceiling or floors are not approved. All drain lines, water lines, gas lines and electrical conduit running along the walls in finished rooms must be boxed in or completely concealed along the wall to facilitate easy cleaning. 22. Please be advised at least 50 foot candles of light are required on all working surfaces and 20 foot candles on all other surfaces in all kitchen, preparation areas, storage areas, service counters, restrooms, and ware washing areas. All lights in the above areas except, restrooms; where cased food is stored and in retail sales areas where package food are sold, must be shielded in an approved manner. All light inside equipment must also be shielded. 23. Please be advised foods, cups, plates and tableware must be adequately protected from customer contamination, such as coughing, sneezing and handling. , 24. To help prevent insect and rodent entry into the building all outer openings including doors and windows must be kept closed or permanent screens or air curtains must be installed on outer openings that will be left open periodically. Weather striping. threshold and/or broom sweeps must be installed on all outside doors to eliminate gaps to the outside. All exit,and restroom doors must be fitted with self -closures. 25. Please be advised floors, walls, ceilings, counter tops, storage shelves, cabinets and all work surfaces, located within all kitchen and food preparation areas, storage areas, custodial closets, restrooms, serving areas, wait station, ware washing areas and walk-ins must be of an approved material that is smooth, non - absorbent, easily cleanable and durable. a) All paints used on the walls and ceilings must be washable, without removing the paint when cleaned. A light colored high gloss paint is recommended. b) All floor/wall junctures and stationary equipment floor junctures in the above listed areas must be provided with approved concave coving. 26. Be advised that the following items are required in each department of the establishment: a) Food product thermometers (0 to 2200F). b) Food handlers gloves and finger cots. c) Approved sanitizer. d) Test kits for the sanitizer. In addition to the $75 plan review application fee paid at the time the plans were submitted for review, a review fee is assessed for the actual review time. The review fee is assessed at a rate of $40 per hour. Currently review cost for this project is $166.00. Please be advised, before the department can give any approval for operation all plan review fees must be must be paid. The plan review billing invoices for this project are attached. The Written plans are approved at this time. Be advised approval of plans, including the above modifications and those outlined in the plan review letter, does not constitute acceptance of the completed structures. Inspections of the premises must be conducted by this department prior to approval for operation and licensure of the establishment. Failure to follow the recommended changes may prevent or delay the licensure. Fjde S The establishment is required to obtain a Retail Food Establishment License. An application for the required license will be provided by the department prior to the opening inspection. Please feel free to contact this department if questions arise, or if I can be of further service at 498-6771. Sincerely, Chris anl6y, REHS Environmental Health Specialist cc: Mark Schmidt, Galloway, Romero & Associates Fort Collins Building Department A f.5 "5