HomeMy WebLinkAbout1120 Montgomery St - Special Inspections/Engineering - 07/26/2006IC 7t- >I- July 26, 2006 Project No: 1466-50-03 S H E A R ENGINEERING Premier Custom Builders, Inc. ENGINEERING 1420 G Blue Spruce Drive Ft. Collins, Colorado 80524 Attn: Dave Phillips Re: Lot 1, Eastgate 2nd Filing (1120 Montgomery Street); Fort Collins, Colorado Dear Mr. Phillips, Shear Engineering Corporation conducted foundation excavation observations for the above referenced site on Friday, July 1, 2005. The soils noted at the bottom of the crawlspace excavation consist primarily of light brown silty sandy clay. The soils noted at the bottom of the garage excavation also consist primarily of light brown silty sandy clay. The soils noted in the excavations are generally consistent with the soils profiles provided by Empire Laboratories, Inc. in the geotechnical investigation report for Eastgate Apartment Complex titled "Report of a Soils and Foundation investigation and Development Corporation, Fort Collins, Colorado"; E.L.I. Project Number 1148-72; report dated April 24, 1972. Boring Logs No. 6 and 10 were the borings taken on this site. Boring Log No. 6 indicated sandy clay to a depth of four feet (4% underlain by silty sandy clay to a depth of five feet (5'), underlain by sand, gravel and cobbles to a depth of fifteen feet (15'), the bottom of the boring. Boring Log No. 10 indicated sandy clay to a depth of three and one half feet (3.5'), underlain by silty sandy clay to a depth of six and one half feet (6.5% underlain by sand, gravel and cobbles to a depth of fifteen feet (15% the bottom of the boring. This lot is suitable for a spread footing foundation system. The foundation plan for the proposed residence prepared by Shear Engineering Corporation, dated January 2005 was used. Footings were designed for a maximum allowable bearing capacity of 2,500 pounds per square foot (dead load plus full live load) and a minimum dead load of 750 pounds per square foot according to the recommendations of the geotechnical investigation report referenced. It was determined that a perimeter drain system was not required based on the depth of excavation. Shear Engineering Corporation was present on Wednesday, July 13, 2005 for footing formwork and footing reinforcing placement observations. Shear Engineering Corporation was present on Monday, July 18, 2005 and Wednesday, July 20, 2005 for foundation wall reinforcing placement observations. These observations were made to confirm that footing formwork and reinforcing placement and foundation wall reinforcing placement were completed in substantial compliance with the direction, details and specifications noted on the foundation plan. All footing formwork and reinforcing placement and foundation wall reinforcing placement was completed in substantial compliance with the direction, details and specifications noted on the foundation plan. 4836 S. College, Suite 12 Ft. Collins, CO 80525 (970) 226-5334 Fax (970) 282-0311 www.shearengineering.com CDLC57c�!__ PAGE 2 July 26, 2006 Project No: 1466-50-03 Re: Lot 1, Eastgate 2nd Filing (1120 Montgomery Street); Fort Collins, Colorado Shear Engineering Corporation was present on Monday, July 25, 2005 for foundation wall dampproofing observations. Dampproofing observations were made to confirm that dampproofing material and application was completed in substantial compliance with ASTM D- 449 Type II and ASTM D-41 specifications and the federal specification SS-A-701. Dampproofing (DECO 20) was applied to the exterior face of concrete basement walls that retain earth and enclosed habitable space. The dampproofing was applied from the top of the footing to the assumed finished grade elevation. Dampproofing coating material and application (DISSCO 521) meets the ASTM D-449 Type II and ASTM D-41 specifications and the federal specification SS-A-701. If you have any questions concerning our observations, please call us at (970) 226-5334 I BWS / rdw cc: City of Fort Collins Building Department