HomeMy WebLinkAbout1120 Montgomery St - Disclosures/Final Energy - 03/30/2006 (4)-ara%s cnerev Scoring 8i3 Oxford LN DATE FT. COLLINS, CO 80525 03/30/06 (970)377-1056 ESTOMER: Premier Custompu'_lders 1120 Montgomery Fort Collins Co JILDING CONDITIONS: Interior Temp = 65 F Volume = 15300 Cu. Ft. Number of Stories = 2 Wind Shield Factor = .9 )USE TEST : Depressurized Fan Model = 3 Performed By SARA ita Points: Exterior Temp = 50 F Above Grade Surface Area = 0 Sq. Ft. Number of Occupants = 2 House Pressure Fan Pressure CFM %Error Fan Configuration 55 41 1119 0.9 Ring A 52 37 1063 —1.0 Ring A 45 32 989 —0.3 Ring A 37 26 893 0.3 Ring A 32 22 822 —0.0 Ring A 24 16 702 0.1 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9989 C = 121.74 n = 0.551 �sults: Air Flow @ 50 Pascals : 1051 CFM50 +/— 0.4% 4.12 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 74.09 Square Inches +/— Equivalent Leakage Area (CANADA) = 127.18 Square Inches +/— Estimated Natural Infiltration (50 Pascal Flow Divided By 12.2) 86 CFM = 43.0 CFM/OCCUPANT = 0.34 AIR CHANGES PER HOUR 3.1% 1.9%