HomeMy WebLinkAbout4426 S College Ave - Miscellaneous/Sign - 03/03/2006DESIGN
3.3-0
FOR (1) SET OF FACE -LIT PAN CHANNEL LETTERS
YY 2 C' S 6.eD cc -2 � /1 '�
8„ 5„
r
y�
END VIEW
MAKE (1) SIGN
CHANNEL LETTER SPECIFICATIONS
LETTER TYPE: FACE -LIT PAN CHANNEL LETTERS
LETTER CONSTRUCTION:.040" PRE -FINISHED ALUMINUM
COLOR INSIDE: WHITE OUTSIDE: BRONZE
FACE MATERIAL: ,1E7" WHITE ACRYLIC #7328
TRIMCAP: 1" BRONZE
RACEWAY SPECS.:.040" ALUMINUM- P.T.M. FASCIA
B"® X B"H X LENGTH
16'-0"
ILLUMINATION: 15 MM 8300 WHITE VOLTARC NEON
TRANSFORMER(S):30 MA
❑ HOUSINGS ■ DOUBLE BACKS ■ CERAMIC BUSHINGS
❑ INDOOR ■ OUTDOOR EI WEEP HOLES
❑ SURVEY REQUIRED DONE BY:
NOTE: FINAL ELECTRICAL HOOK-UP BY OTHERS
OTHER NOTES:
SHAW SIGN C'*�%*NING, INC,
800-493-6244 fax 970-493-6288 106, www.SHAWSIGNcom
CLIENT: HOME LOAN EXPERTS- WORLD SAVINGS LOCATION: FT. COLLINS, CO DATE: 2-28 00 DRAWING #: 157 OOC 1CUSTOMER APPROVAL: DATE:
SCALE:3/4"= 1'-0" I SALESPERSON:JPL DESIGNER: SKIP FILE NAME: WRL1951405
This drawing Is submitted for use In a project being planned for you by Shaw Sign & Awning, Inc. & may not be reproduced, copied, exhibited or manufactured by any other company or persona without written permission from Shaw Sign & Awning, Inc. Violation of the above constitute a compensatory fee to Shaw Sign & Awning, Inc. Due to the difficulty in matching some colors, variations may SHOP
occur during production. All electrical signs will be wired 120 volt primary service unless otherwise noted. Other voltages are available at additional coat. Primary service, time clocks or other electrical devices are not included In this presentation.Shew Sign & Awning, Inc. will not be responsible for damages to unmarked underground utilities, sprinklers end/or telephone cables that may occur. ❑ SKETCH
APPROXIMATE SIGN PLACEMENTS (NOT TO SCALE)