Loading...
HomeMy WebLinkAbout210 W Magnolia St - Correspondence/Building Code - 01/19/2006COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES L � 69 " ZA Fort Collins Neighborhood & Building Services 281 N. Colle e Ave. 7 {_itt-� of i"artC«liins g , P.O, Box 580• Fort Collins CO 80522-0580• Voice: 970 2216760 FAX: 970 224 6134 January 19, 2006 Subject: 210 W. Magnolia St. (Urban Living Lofts at Magnolia) B0507083 Request for use of special provision & local amendment in current building code. The following project is a 4-story residential Group R-1 building with 1st floor S-3 parking garage and 1st floor B office space. The applicant has requested to use 1997 UBC special provision 311.2.2 of the code and a local amendment 907 to remove the one -hour fire resistive construction. This letter is to explain and approve that request. 1. UBC special provision section 311.2.2 allows an S-3 parking garage with R-1 dwellings above to be considered as separate and distinct buildings if the S-3 garage meets Type I construction and is separated from the R-1 above by a 3-hour occupancy separation. In addition this provision allows a B occupancy with the S-3 when a sprinkler system is provided throughout. 2. Local building code amendment 907.2 allows an R-1 occupancy 3-stories or less to use an approved residential -type fire sprinkler system to substitute for the one -hour fire resistive construction. 3. The R-1 sprinkler amendment can only by used when the building has no other occupancies except R-1/U-1. By using the 311.2.2 provision we are allowing the R-1 to be considered separate from the S-3 and the sprinkler amendment can then be used. 4. The project has been reviewed, the S-3 Type-1 construction has been provided, a 3- hour occupancy separation assembly is provided between the S-3/R-1, and the building is fully fire sprinkled. 5. A 3-hour occupancy separation is required by this authority and has been provided between the S-3 and B because the B is an existing building of type III-1 hour construction and does not meet the type I required by section 311.2.2. 6. The 311.2.2 code section affords the R-1 above it to take advantage of 3 stories above the S-3 therefore allowing the 4-story building. The building shall be considered as 2 separate buildings. 1st floor S-3 occupancy using Type - I construction and 2"d 3rd and 4th floor R-1 occupancy type V-1 hour with 907 Sprinkler Substitution removing the 1-hour construction from the R-1. Request approved. 17 Russ Hovland Plans Analyst City of Fort Collins 970-416-2341 rhovland@fcgov.com