Loading...
HomeMy WebLinkAbout2508 Dallas Creek Ct - Disclosures/Air Sealing - 11/09/1999NOV-19-99 FRI 09:41 AM WRITER CORPORATION FAX NO. 19706866614 P. 03 Nov 15 99 02;17p SRRR (970) 2se - 1009 p,p SARA'S ENERGY SCORING 2115 WATER BLOSSOM LANE DATE FT. COLLINS CO 80526 11/09/99 (970) 266-1009 CUSTOMER: Writer 2508 Dallas Creek FORT COLLINS CO 80525 BUILDING CONDITIONS: Interior Temp = 65 F Exterior Temp = 65 F Volume - 42735 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 3 Wind Shield Factor 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM $Error Fan Configuration 53 240 2721 1.7 Ring A 47 207 2S29 -2.0 Ring A 34 174 2321 -1.1 Ring A 20 133 2032 1.3 Ring A 16 117 1907 1.5 Ring A 12 92 1693 -1.9 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9945 C = 828.34 n = 0.295 Results: Air Flow a 50 Pascals 2628 CFM50 +/- 1.1% - 3.69 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) - 353.55 Square Inches +/- 3.3% Equivalent Leakage Area (CANADA) = 479.96 Square Inches +/- 1.9% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) 194 CFM = 64.5 CFM/OCCUPANT 0.27 AIR CHANGES PER HOUR