HomeMy WebLinkAbout2208 Trestle Rd - Special Inspections/Engineering - 05/31/2007Foundation Wall Reinforcement Inspection CLIENT: ` Sequel Homes a coonRoad, Suite Boulder, CTL I THOMPSON ADDRESS: zZOF— LOT 1 BLOCK Z �✓ FILING NO. Z JOB NO f7603 Attn: MIKe Rodriquez Foundation Plan BY h PLAN NO. G DATE J 2- 0 / Foundation Plan ❑ SPREAD FOOTINGS FOOTINGS WITH MINIMUM DEADLOAD ❑ GRADE BEAMS AND PADS ❑ DRILLED FRICTION PIERS ❑ DRILLED PIERS INTO BEDROCK ❑ OTHER r� p CTL/THOMPSON JOB NO. l- G 0 � T ' � � � DATED b � � '� 5 WALL ALIGNMENT OFFSET INCHES Foundation Void L�LREQUIRED THICKNESS ❑ NOT REQUIRED Reinforcing Steel 7i GRADE d7 (/ BAR SIZE NO. OF BARS TOP BOTTOM Z VERTICAL n d HORIZONTAL Instructions to Contractor ,RrIN GENERAL CONFORMANCE WITH PLAN ❑ REJECTED RECOMMENDED CORRECTIVE PROCEDURE Foundation Wall Layout UFER Ground+Locati n of U� QGrroun LOCATION A ' E & ❑ NOT INSTALLED ❑ NOT REQUIRED COMMENT: t' FIELD EPRE ENTATI^VE R VIEWED BY r - DATE OF INSPECTION �' Excavation/Footing Inspection CLIENT: Sequel Homes ul Boulder, CO 80301 Attn: Mike Kodriquez Recommended Foundation 7System�/ / CTL/THOMPSO JOB/J�O. y�57C, � J qO lZO DATED 'f7 "!/ S ❑ SPREAD FOOTINGS MAXIMUM SOIL PRESSURE OF MINIMUM WIDTH PSF. INCHES FOOTINGS WITH MINIMUM DEADLOAD 77 MAXIMUM SOIL PRESSURE OF S. Oy p PSF. MINIMUM DEADLOAD PRESSURE OF / 0 ,P V PSF. PROVIDEA & // INCH �VO)IID,,,, BENEATH �13TDE BEAMS MINIMUM WIDTH / D ( PJLOU I O X a INCHES ❑ GRADE BEAMS AND PADS MAXIMUM SOIL PRESSURE OF PSF. MINIMUM DEADLOAD PRESSURE OF PROVIDE A MINIMUM WIDTH Foundation Plan BY G- T-G- f PSF. INCH VOID BENEATH GRADE BEAMS INCHES PLAN NO. ° _ F DATE -Z x '0 WALL FOOTINGWIDTH d (INCHES) DEPTH (INCHES) COLUMN PAD fQ 1 i94Z (INCHES) DEPTH ly (INCHES) COLUMN PAD '�(INCHES) DEPTH _Z t,� (INCHES) REINFORCEMENT AS PER PLAN: R YES ❑ NO ❑ NONE REOUIRED KAT SITE ❑ INSTALLED Soil Conditions At Footing evel t UPPER LEVEL OEM Ground Water Conditions ;NONE IN EXCAVATION NONE ENCOUNTERED IN BORING NO. O �_ FEET ❑ ENCOUNTERED AT FEET IN BORING NO. Remarks: CTL I THOMPSON ADDRESS: 2 woe LOT BLOCK �i S �/ FILING NO. JOB NO. Ar a?61y Foundation Layout INDICATES APPROXIMATE DEPTH/WIDTH MEASUREMENT LOCATION Instructions to Contractor IN GENERAL CONFORMANCE WITH PLAN ❑ REJECTED RECOMMENDED CORRECTIVE PROCEDURE _r FIELD REPRESENTATIVE 'A' e/(/• REVIEWED BY - ^r DATE OF INSPECTION --' A) Foundation Wall Drain/ Void/Waterproofing Inspection CLIENT: Sequel Homes Boulder, CO 80301 Attn: MIKe Rodriquez Foundatigo�j19 Plan,,, BY L / h' (�P, PLAN NO. Foundation Type ❑ SPREAD FOOTINGS ❑ GRADE BEAMS AND PADS F-1 DRILLED FRICTION PIERS ❑ DRILLED PIERS INTO BEDROCK ,V I FOOTING W/MINIMUM ❑ OTHER DEADLOAD �± / CTLITHOMPSON JOB NO. 1 e'er% _/,7 " DATED y/9 Foundation Void IKREQUIRED THICKNESS INCHES JR MEASUREDTHICKNESSINCHES Foundation Wall Condition ❑ EXPOSED STEEL ❑ SURFACE PROBLEMS (HONEYCOMBING, ETC.) (IF CHECKED, SHOW LOCATION ON SKETCH) Recommended Drain Type EXTERIOR ❑ INTERIOR ❑ BELOW FILL ❑ BELOW SLAB FIG. INSTALLED PIPE DIAMETER INCHES WALL HEIGHT 1 INCHES DEPTH -TOP OF WALL TO BOTTOM OF TRENCH Z&Z% INCHES 4SLAB ON GRADE [-]STRUCTURAL FLOOR PIPE INSTALLED u� y<GRAVEL INSTALLED, NOMINAL SIZE Type of Outlet JKGRAVrrY, BELOW SEWER ❑ SUMP PIT ❑ UNDERDRAIN SERVICE CONNECTION VISIBLE (AT STUB) XFqundation Void: Z GENERAL CONFORMANCE WITH RECOMMENDATIONS ❑ REJECTED Foundation Wall Drain: XN GENERAL CONFORMANCE WITH RECOMMENDATIONS ❑ REJECTED Fou�ndation Waterproofing: 2,IN%GENERAL CONFORMANCE WITH RECOMMENDATIONS ❑ REJECTED ❑ Exterior Insulation MANUFACTURER HEIGHT FEET DISTANCE BELOW FOUNDATION WALL FEET R P 0 R A T E D ADDRESS: z-z-o LOT -BLOCK Z FILING NO. Z JOB NO. �G 7.36 Foundation Wall Layout � �L RECOMMENDED CORRECTIVE PROCEDURE FIELD REPRE ENTATIV C REVIEWED BY S' 2 DATE OF INSPECTION