HomeMy WebLinkAbout2607 Yorkshire St - Special Inspections/Engineering - 07/05/2007 (2)A.R.G. ENGINEERS & ASSOCIATES, INC. 2309 North Ridge Court Fort Collins, Colorado 80521 Phone/Fax 970-498-8307 Cell Phone 970-663-0161 �% 3 July 5, 2007 SUBJECT: ERICKSON ADDITION, FORT COLLINS, COLORADO The open hole inspection was performed on June 18, 2007. Footing sizes are consistent with supporting soils. No perimeter drainage system is required. Footing forming and reinforcing was observed on June 18, 2007. Contractor was instructed to add 2 #4 dowels x 24" long, epoxy bonded into existing foundation. Wall forming and reinforcing was observed on or about June 25, 2007. Work was in accordance with design drawings. Damp -proofing was completed and observed on July 9, 2007. No exceptions were taken. Sincerely, Arthur R. Griffith Colorado PE # 9404 r�G Q�n �.. •••R, CLQ� �. �•,� ",r� Jj4'C