HomeMy WebLinkAbout3514 Green Spring Dr - Special Inspections/Engineering - 06/06/2006Drilled Pier Quality Assurance Observation Per the clients request, a representative of SECURE has visually observed the drilling of the piers at the site referenced below. The following summarizes our observations and opinions at the time of our visit. Client: Cjc—+orn 1�2p r.��,x •2--7r) Ll rnr,, C oll:r,s , /fos77 - -- Secure Job #: SF 0 1 Z'n-1 Date: rn - rca Contact: C ,h. cy i s t- Site Address: ,ic. F"or4 1:rc, l n Lot: (1 Block: l2 Filing: Subdivision: f' •, _ c.. r . < n Installation Contractor: Weather: Ll e(. •r , L70°r- SECURE CONSULTING ENGINEERS 1 A CTL I THOMPSON COMPANY Foundation Plan: f' E Date: H -0-0(n Job: - F o 12. n-) Soil Report: r 'r T hoµ psi Job #: FC Date: erg Drilled Pier Specifications Reinforcing Steel: Z *L q C r:,, (r. 0 Pier Diameter 12 i -c h 17Min. Pier Length: 27,ck i Z 4 F1 F Min. Penetration I I f }- I _'F t y. f! Planned Support Stratum: ;.� I i 'J or. e. Other: Description, E=Elevation of top pier, D=Pier Diameter, L=Total Pier Length, P=Penetration, H2O=Depth to Water Pier E D L P H2O 0 (k Z 27fk I1 f4- �o 2 3 4 5 6 7 8 9 10 Subsurface Conditions observed during drilling: D — g f- � // (�2 �-o 0 r b 4� hole Installation Methods Used ❑ Pumping ❑ Casing ' �t�IO Cont,Reae on5�+e. ❑ Drill & Pour ❑ Tremy Summary of opinions: It is our opinion that the drilled piers observed were in general conformance with plans and specifications. ❑ It is our opinion that the drilled piers were not in general conformance with plans and specifications. Corrective Actions: Pier E D L P H2O 11 12 13 14 15 16 17 18 19 20 Field Representative: ACC Reviewed By: Secure Foundations, LLC 9 211 West Magnolia Street, Ft. Collins, CO 80521 • Ph: 970-472-6255 1 e Reinforcing Steel Quality Assurance Observation Per the clients request, a representative of SECURE has visually observed the reinforcement within the formwork under construction at the site referenced below. The following summarizes our observations and opinions at the time of our visit. SECURE CONSULTING ENGINEERS A CTL I THOMPSON COMPANY Client: C(,.4tr)m EnyfrnnMPrsts Site Address: 35IA Cr?en rrtnn ri.\/e P.O. LBo)c 270654 Fnrt Q)lILns CO. 8o524 FnrF C011in0, C.0 13 Secure Job #: 5F01z07 Lot: I i Block: IZ Filing: Date: O6112.10o, Contact: Charlie Subdivision: Fnssil Lake Ranch Reinforcing Plan Information Plan By: Reinforcing Type(s): ❑ footing ❑ grade beam ❑ structural slab ❑ column L(foundation wall ❑ pier cap ❑ slab -on -grade ❑ other Wall / Grade Beam Reinforcing Steel Grade Horz. Vert./Ties 1 60 (2) a56arS+op, 2Cp0 .c 1 ' 3 0 (2)tf5 6ar5 top t c 4 Pier Cap / Slab Reinforcing Steel Grade Longitudinal Lateral A B C D UFER Ground ld Installed - Location ❑ Not Observed Max / Min wall height observed: 9 Pi: / 3 Ft If void forms are required, are they installed as Wre ommended? yes , ❑ no Required thickness: g in. Concrete on -site? ❑ yes Yno (% poured = +/-0'7o) Weather: ti 9 5° F Clear Notes: Smmmary of Opinions It- is our opinion that the reinforcing steel observed was in general conformance with the plan. ❑ It is our opinion that the reinforcing steel observed was not in general conformance with the plan. (2rid observation required). Deficiencies noted: Secure Foundations, LLC • 211 West Magnolia Street, Ft. Collins, CO 80521 0 Ph: 970-472-6255 • Fax: 970-472-6256 !' tit Perimeter Drain / Dampproofin Quality Assurance Observation Per the clients request, a representative of SECURE has visually observed the perimeter drain and/or dampproofing at the site referenced above. The following summarizes our observations and opinions at the time of our visit. Client: l , oc A or+1 En V! rro ni •P. its Secure Job #: 5FQJZ 07 Date: & .Zo •p(a Contact: (-�n or Proiect Specifications Foundation Plan By: E_ Date H- 17-o6, Job# SF0i207 Geotechnical Report By: CT LZ-rt4 0("k P500 Date %(i l S f ' Zoole Job# R. 0 31 Zed - I? o Recommended Drain type? A Exterior perimeter ❑ Interior ❑ other Observations Perimeter drain observed around: Oasement ❑ Crawlspace ❑ Other: Where does the perimeter drain discharge? ❑ Daylight Sump pit ❑ Subdivision drain Dampproofing observed around: bBasement ❑ Crawlspace ❑ All backfill areas SECU]" CONSULTING ENGINEERS A CTL I THOMPSON COMPANY Site Address: Lot: Block: 2__ Filing: Subdivision: Foss, I Lai.-G 2o.n, -6 Summary of Opinions X',It is our opinion that the foundation drain and/or dampproofing observed generally conform with the project referenced above. ❑ It is our opinion that the foundation drain and/or dampproofing observed differs significantly from the project specifications (2nd observation required). Comments inky �"'r exCa-vim 4 �� 4-o Corrective Action: Chars %IP& CJ-(orcl r�,oAi 4;14G a Secure Foundations, LLC 9 211 West Magnolia Street, Ft. Collins, CO 80521 a Ph: 970-472-6255 • Fax: 970-472-6256 ., �.t T,�2vC,Zv2RL F�oofZ Framinz Quality Assurance Observation Per the clients request, a representative of SECURE has visually observed portions of the framing under construction at the site referenced below. The purpose of our observations is to verify general conformance with plans. This work is not intended to replace regular framing inspections provided by the local building department. SECURE CONSULTING ENGINEERS A CTL I THOMPSON COMPANY Client: Site Address: 3�14 61 4F-e.y SpF, w(1 DRt Uj�_ , )4-joM ' r1 V &onmzn%S Fir � (J1(;J1-s (Q Secure Job #: SFo )20 I Lot: _j l _ Block: 12- Filing: Date: v Z7 ov Contact: e Subdivision: toss ' 1 Lc kC E an c h Framing Plan Information Plan By: JET u C'—E, Date: q 7 O(7 Job#: SF017-07 Sheet 5I of 5Z- Site Observation Notes: lJl Be.Yy in 910-ce "-18 %op-ed �oqe&c- -l2 of CIe nca C Bms (19 n neQ`d o mo �Ghy id i lsion _Ncc� ,bie. �cle: UoL2t 15 rcEv_. 5o, 12" (1A lleeolecSr�� acc es ,; feel S-o De,�,k;nn!) 12ec fJo n Z. LO.�✓f � �j:JJ �" (�Q.W Lf �t P� -�O ty�cnE l�}�;n ��� Gltar a-ncc-E 1-O ^^- -3 CY 211 ��� J.j W Bth 4-o irxPri-)i wI z2 s, P1v c e_ s\Ub per p ,-n Summary of Opinions X,,It is our opinion'that the framing observed was in general conformance with the framing plans. ❑ It is our opinion that the framing observed was not in general conformance with the framing plan. (2"d observation required). Exceptions Noted: Secure Foundations, LLC 0 211 West Magnolia Street, Ft. Collins, CO 80521 0 Ph: 970-472-6255 0 Fax: 970-472-6256