Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1307 E Prospect Rd - Miscellaneous/Other - 02/05/2007
FC ELECTRIC SYSTEMS SUMMARY Project Project Address: 1307 Prospect St. in Fort C13V3COV Dat : 0 /05/07 Information Fort Collins Club For Building Dept. Applicant Name: Fort Collins Club Use Applicant Address: 1307 Prospect St. Fort Collins, CO 80521 Applicant Phone: (970) 224-2582 Mac Durgeloh (owner's repr.) Project Description: Fittness Centel - Applicant i Complete Building Department Enter valu List ref. to Check if documentation Check Code Sect. or circle plans or is acceptable. Provide notes Time of when Number Requirements Yes or No enter N/A o inspector, when necessary Insp. performed 401.1 Electrical Distribution 401.1.1 Check Metering Provisions Feeders divided by use: No N/A ❑ Rough ❑ Shared HVAC/SWH: No N/A ❑ Rough ❑ 401.1.2 Electrical Schematic No N/A ❑ Final ❑ 401.2 Electric Motors 401.2.1 Efficiency No N/A ❑ Rough ❑ excep#I MultispeedMotors No N/A ❑ excep 42 Motor included in 403 Yes Mech ❑ 401.3 Lighting Power Allowance N/A N/A 401.3.1 Building Exteriors ELPA: ❑ Fxterior CLIP: N/A N/A ❑ Rough ❑ excep List exception if Applicable: No N/A ❑ 401.3.1.1 Min. ext. lamp/ballast efficac No N/A ❑ Final ❑ excep List exception if Applicable: No N/A ❑ Building Interiors ILPA: 24,524 Worksheet ❑ Interior CLP: 24,509 Worksheet ❑ Rough ❑ excep #I Theater, stage, broadcasting No N/A ❑ Final ❑ excep 42 Sp. medical, dental. research No N/A ❑ Final ❑ excep #3 Gallery, museum, monument No N/A ❑ Final ❑ excep #4 Indoor plants 10 PM - 6 am No N/A ❑ Final ❑ excep 95 Normally off emer. lighting Yes N/A ❑ Final ❑ excep #6 High -risk security areas No N/A ❑ Final ❑ excep #7 Physically impaired, aged No N/A ❑ Final ❑ excep 48 Dwelling units No N/A ❑ Final ❑ excep 49 Task lighting not attached No N/A ❑ Final ❑ 401.33 Auto light control required No N/A ❑ Final ❑ Manual turn-off switches Yes Plans ❑ Final ❑ Ft. Candle set pints on plans No I N/A ❑ Final ❑ 401.3.4 Lighting Controls Yes Plans 401.3.4. 1 Area controls each space ❑ Rough ❑ Remotely controlled lights Yes Plans ❑ Filial ❑ 401.3.4.2 Day lighting controls No N/A ❑ Rou h Elg excep insufficient daylighting or EA Yes N/A ❑ Rough ❑ 401.3.4.3 Display lighting conn'ols No N/A ❑ Rouggh ❑ 40L')AA Resnoom occupancy sensors No N/A ❑ Final ❑ 401.3.4.5 1-10tel/Motel guest room ❑ excep Switch at each room entry 401.3.4.6 Exterior light switching :No N/A N/A ❑ El Rough Final ❑ El401.3.4.7 Automatic shut-off controls N/A El Filial El Manual override switches N/A ❑ Rough ❑ 401.3.5 Ballasts No Yes N/A > 90% 401.3.5.1 Tandem wiring 401.3.5.2 Power Factor ❑ ❑ Rough ❑ excep Dimming Ballasts No N/A ❑ Final ❑ 401.3.5.3 Lamp/ballast luminour effic. Yes N/A ❑ Final ❑ 401.3.6 Safet /security lighting effiic. Yes N/A ❑ Final ❑ Page I of I Fort Collins Compliance Supplement Nonresidential Energy Code FC LIGHTING WATTAGE WORKSHEET Project Information Project Address: 1307 Prospect St. in Fort Collins, CO 80521 Fort Collins Club Date: 02/05/07 For Building Department Use Applicant Name: Applicant Address: Applicant Phone: GENERAL. Calculate Exterior Lighting Power Alloivance (ELPA) and Exterior Connected Lighting Power (CLP) on this page. For inferior lighling, calculate the Interior Lighting Power Allowance (ILPA) on page 2, using the buildingspace method or the specific apace method. Use page 3 to calculate the proposed hilerior (CLP). EXTERIOR LIGHTING POWER ALLOWANCE (Section 401.3.1 and Table 401.3.1) Area or Allowed Allowed W/sq. ft. Lineal Watts Area Description or W/lineal ft. Feet D x 1 Exit (with or without canopy) 20 W/lin. ft. of door opening 6 120 Enhance (without canopy) 30 W/lin. ft. of door opening 0 Entrance (with canopy) 3 W/sq. It. of canopied area 96 288 Building exterior surfaces/facades 0.25 W/sq. ft. of vertical area to be illuminated 2,068 517 Canopy lighting 3 W/sq. ft. ofcanopied area 0 PROPOSED EXTERIOR CONNECTED LIGHTING POWER (CLP) Fixture Description Number Proposed ID fixture size & type, lamp type & of Watts/ Watts Location No. number, ballast type, lens/louver type) Fixtures Fixture H x 1 Exit (with or without canopy) East AA Wall bracket, metal halide, 1-70W. 1 88 88 0 0 Exit Lighting Total CLP (Compare to allowed watts above): 88 Entrance (without canopy) 0 0 0 Entrance (without canopy) Lighting Total CLP (Compar( to allowed watts above): 0 Entrance (with canopy) East CC Surface drum, fluorescent, 2-32W 2 66 132 0 0 Entrance (with canopy) Lighting Total CLP (Compare to allowed watts above): 132 Building exterior surfaces/facades North BB Wall bracket, metal halide, 1-150W._.j 3 185 555 Wall bracket, fluorescent, 2-32W North DD 3 32 96 0 Building exterior surfaces/facades Total CLP (Compare withal we tts above): 651 Canopy lighting (as pumps, drive-ins, etc..) 0 0 0 Canopy lighting Total CLP (Compare with allowed watts above): 0 UMI\IMM12lokmI9,11LMr1l7►671ralDo0IICyn PROJECT INFO: Enter the basic project information indicated, including date of submittal. EXTERIOR LIGHTING POWER ALLOWANCE: Enter the areas from plans, multiply D times 1, then total J. PROPOSED EXTERIOR CONNECTED LIGHTING POWER (this page): Enter information from lighting schedule, multiply 1-1 times 1, then total J. Page 1 of 3 Fort Collins Compliance Supplement -Nonresidential Energy Code June 1996 FC LIGHTING WATTAGE WORKSHEET (continued) ILPA - BUILDING SPACE METHOD (Section 401.3.2 (a) and Table 401.3.2 (a) Location Building Space Activity (from Table 401.3.2a) Area (sq. ft.)_W/s Allowed . ft. Allowed Watts H x 1 Total Interior Lighting Power Allowance (ILPA): 1 p ILPA - SPECIFIC SPACE METHOD Section 401.3.2 b and Tables 401.3.2 b-d Room Number Specific Space Activity (from Tables 401.3.2b-d) Area (sq. ft. No. of Similar Spaces Allowed W/s . ft. Allowed Watts G x H x 1 Lobby/Wait.500,501 Lobby 216 2 1.0 216 Hair/Facial 502,3,4,11 Beauty Parlor 1,032 4 1.6 1,651 Massage 506,7,8 Physical Therapy 456 3 1.6 730 Suntan 509A,B Beauty Parlor 154 2 1.6 246 Toilets 510,16,17 Toilet & Washroom 210 3 0.8 168 Star. 512,23B,27,18 Storage active 349 4 0.6 209 Equip.513,20 Elect/Meth. 114 2 1.5 171 Hall 515, Spa area Corridor 514 2 0.8 411 Laundry 519 Laundry/Washing 203 1 0.9 183 Office 521,22 Office Cat.1 198 2 1.5 297 523,24,26,28,29,30,32 General Exercising 7,023 7 1.0 7,023 Stairs 525,31 Stair active 301 2 0.6 181 0 Meeting 550 Conf./Meeting 504 1 1.9 958 551,60,63,64,65,66 General Exercising 10,144 6 1.0 10,144 Toilets 552,53 Toilet & Washroom 344 2 0.8 275 Stor. 557,59 Storage active 565 2 0.6 339 Elev. Lobby 556 Elevator Lobby 102 1 0.8 82 Hall561 Corridor 432 1 0.8 346 Childcare108B Recreation area 640 1 1.0 640 Offices 118 Office Cat.1 170 1 1.5 255 0 0 0 0 0 0 I otal Interior Lighting Power Allowance (ILPA): 1 24,524 DETAILED INSTRUCTIONS FOR THIS PAGE INTERIOR LIGHTING POWER ALLOWANCE - BUILDING SPACE METHOD: This the simplest option for compli< Location, space activity and area: Enter the floor/room, activity per Table 401.3.2a, and the area from the plan. INTERIOR LIGHTING POWER ALLOWANCE - SPECIFIC SPACE METHOD: This option offers more flexibility. Room, space activity, area and number of similar spaces: Enter the room number, activity as per Tables 401.3.2b-d, area and number of similar spaces from the plans. Allowed W/sq. ft: Enter the corresponding values fi-om Tables 401.3.2b-d. Total watts allowed: Multiply columns G. H, and I. then total column J. Page 2 of 3 Fort Collins Compliance Supplement -Nonresidential Energy Code .tune 1996 FC L.ICHTING WATTAGE WORKSHEET (continued) 000©©0®0® PROPOSED INTERIOR CONNECTED LIGHTING POWER (CLIP) Location [Lobby/Waiting 500,01 lD No. L Fixture Description (Fixture size & type, lamp type & number, ballast type, lens/louver type) Pendant, low voltage, 1-35W Number of Fixtures Watts/ Fixture Proposed Watts (H x 1) 4 35 140 Q Sconce, low voltage, 1-35W. 3 35 105 T Track, low voltage, 5-35W. 1 175 175 Hair/Facial 502,3,4,11 I U Strip, fluorescent, 1-32W, Electronic 4 34 136 D1 Troffer, fluorescent, 3-32W, Electronic 11 87 957 R Downlight, fluorescent, 1-32W. Electronic 5 34 170 Massage 506,7,8,9A,9B I K Sconce, Incandescent, 1-60W. 11 60 660 C Troffer, fluorescent, 2-32W, Electronic 3 66 198 Toilets 510,16,17 I H Sconce, fluorescent, 2-17W, Electronic 2 35 70 R Downlight, fluorescent, 1-32W. Electronic 3 34 102 Q Sconce, low voltage, 1-35W. 2 35 70 Stor.512,18,23B,27,13,20 I C Troffer, fluorescent, 2-32W, Electronic 1 87 87 A Wraparound, fluorescent, 2-32W, Electronic 2 66 132 B Troffer, fluorescent, 2-32W, Electronic 4 66 264 Hall 515, Spa hall area Q1 Sconce, fluorescent, 1-13W., Electronic 1 15 15 R Downlight, fluorescent, 1-32W. Electronic 8 34 272 Q Sconce, low voltage, 1-35W. 3 35 105 Laundry 519 A Wraparound, fluorescent, 2-32W, Electronic 3 66 198 Office 521,22 D Troffer, fluorescent, 3-32W, Electronic 2 87 174 523,24,26,28,29,20,32 C Troffer, fluorescent, 2-32W, Electronic 16 66 1,056 F Pendant, fluorescent, 2-32W, Electronic 12 66 792 M Troffer, fluorescent, 4-54W, Electronic 26 216 5,616 Stairs 525,531 H Sconce, fluorescent, 2-17W, Electronic 2 35 70 R Downlight, fluorescent, 1-32W. Electronic 2 34 68 0 Meeting 550 D1 Troffer, fluorescent, 3-32W, Electronic 6 87 522 R1 Downlight, incandescent, 1-75W. Electronic 4 75 300 R Downlight, fluorescent, 1-32W. Electronic 1 34 34 551,60,63,64,65,66 C Troffer, fluorescent, 2-32W, Electronic 6 66 396 F Pendant, fluorescent, 2-32W, Electronic 4 66 264 M Troffer, fluorescent, 4-54W, Electronic 43 216 9,288 N Pendant, low -voltage, 1-50W, Electronic 3 50 150 Toilets 552,53 I H Sconce, fluorescent, 2-17W, Electronic 3 35 105 R Downlight, fluorescent, 1-32W. Electronic 7 34 238 Storage 557,59 A Wraparound, fluorescent, 2-32W, Electronic 6 66 396 B Troffer, fluorescent, 2-32W, Electronic 1 66 66 Elevator Lobby 556 G Pendant, fluorescent, 2-32W, Electronic 2 34 68 orridor 561 C Troffer, fluorescent, 2-32W, Electronic 4 66 264 0 hildcare 108B D1 Troffer, fluorescent, 3-32W, Electronic 6 87 522 Jffice 118 P Troffer, fluorescent, 2-31 W, Electronic 4 66 1 264 Total InteriorCPL:1 24,509 DETAILED INSTRUCTIONS FOR THIS PACE PROPOSED INTERIOR CONNECTED LIGHTING POWER (CLP): Location, I D no., fixture description, number of fixtures, wafts/fixture: Enter the floor/room fixture ID. description, number of each, and watts for each fixture from the lighting schedule on the plans. Proposed watts: Multiply columns H and I, and then total column J. COMPLIANCE: Interior connected lighting power watts (or adjusted lighting power) must be less than the total watts allowed. Page 3 of 3 Fort Collins Compliance Supplement -Nonresidential Energy Code June 1996