HomeMy WebLinkAbout2244 Forecastle Dr - Special Inspections/Engineering - 01/29/2007Irerracon Consulting Engineers 8. Scientists January 29, 2007 Aspen Homes 3037 N. Taft Avenue Loveland, Colorado 80538 Attn: Mr. Jammie Sabin Re: Foundation Footing Sizes, Wall Steel and CEE Observations Maple Hill Residential Subdivision 2244 Forecastle Drive — Lot 5 Block 24 Fort Collins, Colorado Terracon Project No. 20045204 Dear Mr. Sabin: 301 North Howes Fort Collins, Colorado 80521 Phone 970.484.0359 Fax 970.484.0454 www.terracon.com A representative from Terracon observed the interior and exterior footing sizes and wall steel reinforcement, including the "concrete -encased electrode" (CEE), for the above referenced lot on January 22 and 24, as requested. Observations made during the foundation construction indicate that the interior and exterior footing sizes, wall steel and CEE placement were in general accordance with the plans for this project. Sincerely, TERRACON Todd A. Turney Field Project Manager Copies: Addressee (5) inager Delivering Success for Clients and Employees Since 1965 More Than 80 Offices Nationwide January 31, 2007 Aspen Homes 3037 N. Taft Avenue Loveland, Colorado 80538 Attn: Mr. Jammie Sabin Re: Exterior Perimeter Drain Observation Proposed Single Family Residence Maple Hill Subdivision 2244 Forecastle Drive — Lot 5 Block 24 Fort Collins, Colorado Terracon Project No. 20045204 Dear Mr. Sabin: Irerracon Consulting Engineers S Scientists 301 North Howes Fort Collins, Colorado 80521 Phone 970.484.0359 Fax 970.484.0454 www.terracon.com A representative from Terracon observed the exterior perimeter drain at the above referenced address within the Maple Hill development on January 31, 2007, as requested. At the time of our site visits, a 4-inch diameter, perforated pipe had been placed around the exterior perimeter of the basement/lower-level foundation and was observed to exhibit positive gravity flow toward a sump pit located within the lower level portion of the residence. The pipe was observed to have a layer of/z - inch washed gravel beneath it. The waterproof dampening was also observed and in our opinion was uniformly applied to the exterior foundations. In our opinion the portion of the exterior perimeter drainage system observed was constructed in general accordance with the plans and specifications for the project. Sincerely, TERRACON Todd A. Turney Field Project Manager Copies to: (5) Addressee )0 David A. Ri V SSi E^I q Geotechnical Manager Delivering Success for Clients and Employees Since 1965 More Than 80 Offices Nationwide