HomeMy WebLinkAbout2224 Trestle Rd - Special Inspections/Engineering - 12/26/2006Reinforcement Inspection
CLIENT: Sequel Homes
Attn: F, ggy'Kelley
Foundation Plan
BY
PLAN NO. DATE
Foundation Plan
❑ SPREAD FOOTINGS
„FOOTINGS WITH MINIMUM DEADLOAD
❑ GRADE BEAMS AND PADS
❑ DRILLED FRICTION PIERS
❑ DRILLED PIERS INTO BEDROCK
❑ OTHER rr //
CTLrrHOMPSON JOB NO.�Gh3 / �b -1Z0 DATEDZ'
WALL ALIGNMENT OFFSET L/ INCHES
Foundation Void rt
REQUIRED THICKNESS Gt INCHES
❑ NOT REQUIRED
Reinforcing St el
GRADE C BAR SIZE
NO. OF BARS
TOP Z.--.- �/
BOTTOM
VERTICAL '®
HORIZONTAL
Instructions to Contractor
.?jZN-GENERAL CONFORMANCE WITH PLAN
❑ REJECTED
RECOMMENDED CORRECTIVE PROCEDURE
�060 S� l3
ADDRESS:
Z 1-7-11
q 2
LOT Z 1 / BLOCK z '7
FILING NO. Z JOB NO. t^c,06I
Foundation Wall Layout
UFER Ground+Location of UFER Ground
❑ LOCATION
❑ NOT INSTALLED
_WNOT REQUIRED
COMMENT:
/ FIELD-
\,/
R VIEWED BY
—F-0'b
,
DATE OF INSPECTION
Foundation 11'all Drain/
• MAN
N C D B P 0Otw*A ,.WET41k9q,
10)
CLIENT: Sequel Homes
2919 valmont Koad, ui e
Boulder, CO 80301
Attn: Peggy a ey
Foundation Plan
BY 1 PLAN NO.r••a"�
Foundation Type
❑ SPREAD FOOTINGS ❑ GRADE BEAMS AND PADS
❑ DRILLED FRICTION PIERS ❑ DRILLED PIERS INTO BEDROCK
,FOOTING W/MINIMUM ❑ OTHER
DEADLOAD
CTLITHOMPSON JOB NO.FL%DATED b-6-05
Foundation Void
❑ REQUIRED THICKNESS_
MEASURED THICKNESS
Foundation Wall Condition
❑ EXPOSED STEEL
❑ SURFACE PROBLEMS (HONEYCOMBING, ETC.)
(IF CHECKED, SHOW LOCATION ON SKETCH)
INCHES
INCHES
Recommended Drain Type
❑ EXTERIOR ❑ INTERIOR ❑ BELOW FILL ❑ BELOW SLAB
FIG.
INSTALLED PIPE DIAMETER
WALL HEIGHT
DEPTH -TOP OF WALL TO BOTTOM OF TRENCH
❑ SLAB ON GRADE ❑ STRUCTURALFLOOR
❑ PIPE INSTALLED
❑ GRAVEL INSTALLED, NOMINAL SIZE
Type of Outlet
❑ GRAVITY, BELOW SEWER ❑ SUMP PIT
❑ UNDERDRAIN SERVICE CONNECTION VISIBLE (AT STUB)
❑' Foundation Void:
❑.IN GENERAL CONFORMANCE WITH RECOMMENDATIONS
❑ REJECTED
❑ Foundation Wall Drain:
❑ IN GENERAL CONFORMANCE WITH RECOMMENDATIONS
❑ REJECTED
gFoundation Waterproofing:
�gjN GENERAL CONFORMANCE WITH RECOMMENDATIONS
❑ REJECTED
❑ Exterior Insulation
MANUFACTURER
HEIGHT
DISTANCE BELOW FOUNDATION WALL
FEET
FEET
INCHES
INCHES
INCHES
ADDRESS: 5- '
Z Z7,%
LOT BLOCK LTJ
FILING NO. •2. JOB NO.4
Foundation Wall Layout
RECOMMENDED CORRECTIVE PROCEDURE
FIELD R RESENTATIVE
<. U' 9 i
REVIEWED BY
DATE OF INSPECTION -use /C3P+9 i_S':-e
`0
Excavation/Footing
Inspection
CLIENT: Sequel Homes
Road,2919 Valmont
Boulder,
CO 80301
Recommended Foundation System
CTL/THOMPSON JOB NO. l"" C�3!fWZ - /9;b
DATED &'(9-05--
❑ SPREAD FOOTINGS
MAXIMUM SOIL PRESSURE OF PSF.
MINIMUM WIDTH INCHES
FOOTINGS WITH MINIMUM DEADLOAD ��
MAXIMUM SOIL PRESSURE OF 2�lJ/
g.��,.� - PSF.
MINIMUM DEADLOA�DfPRESSURE OF �(/ PSF.
PROVIDE A 6 INCH VOID BENEATH GRADE BEAMS
MINIMUM WIDTH �� INCHES
❑ GRADE BEAMS AND PADS
MAXIMUM SOIL PRESSURE OF PSF.
MINIMUM DEADLOAD PRESSURE OF PSF.
PROVIDE A INCH VOID BENEATH GRADE BEAMS
MINIMUM WIDTH INCHES
Foundation Plan
BY
PLAN NO. DATE
DATE
WALL FOOTING WIDTH (INCHES) DEPTH (INCHES)
COLUMN PAD (INCHES) DEPTH (INCHES)
COLUMN PAD (INCHES) DEPTH (INCHES)
REINFORCEMENT AS PER PLAN:
® YES ❑ NO ❑ NONE REQUIRED
® AT SITE ❑ INSTALLED
ADDRES%,,,,,,,,,4_
caw
3
LOT � � BLOCK
FILING NO. 0� JOB NO. 6l? Q a 111
Foundation Layout
® INDICATES APPROXIMATE DEPTHIWIDTH MEASUREMENT LOCATION
Soil Conditions At Footing Level Instructions to Contractor
U[P/R�ER LEVEL —�1 5A&.tw I SIAVf �Ok)AJ I -"4-f" It IN GENERAL CONFORMANCE WITH PLAN
L(j-�ll'{P%N ❑ REJECTED
RECOMMENDED CORRECTIVE PROCEDURE
LOWER LEVEL��� SLY''(__rQplSii`'a
Ground Water Conditions
NONE IN EXCAVATION
❑ NONE ENCOUNTERED IN BORING NO. TO FEET
❑ ENCOUNTERED AT FEET IN BORING NO.
Remarks:
Tu6RC-W AS IV 6 Q R nt 4Tv9 IQ 64R
AA'.6AC