Loading...
HomeMy WebLinkAbout3627 Big Dipper Dr - Site Plans/Single Family New - 02/20/2007PLOT PLAN .FOR f 4. I 4. the Plda"e' n $„ LOT 114 ,SUBDIVISION LLOW BROOK , CITY OF FORT .COLLINS, COUNTY OF LARIMER, STATE OF C0126RADO ADDRESS 3627: BIG DIPPER DRIVE °51.000 S89907'31 "E o : ` 6'U EL. LOT 11 :� \I lY fell �o � 6 UNCOIfliED a1' v, STD DECK FRP ° MT ---1= 1pt� 11.7 W I � f �LPLAN 2406 .N TGB= 103� M C, ELEV-E CRAWL I C'.Yg;.>/ LOT 775 Z o BASEMENT � o I N � 9.1 L1 2.1' O r` 2 CAR ;n 0 6.5' GARAGE N ro Lbo� n \°\J � \°\ 10.3' O h Oj A 2S' I 6.2' II Tp COVERED I L I: L ........... PORCH , —j 71 v' 35�#SiE F II 9'UE 61% ia o1 O O qq b 51. 00' S89 07J1 "E I1; Li tiq 3� BIG DIPPER DRIVE LFNFRAI NOTES I. THIS PLOT PLAN DOES NOT SHOW LOCATION OF WINDOW WELLS. FOR THEIR LOCATION SEE STRUCTURAL ENGINEERED PLANS. 2. THIS PLOT PLAN IS BASED ON INFORMATION PROVIDED TO CARROLL & LANGE BY THE BUILDER / DEVELOPER. 3. DIMENSIONS SHOWN AROUND THE PERIMETER OF THE STRUCTURE ARE TO THE EXTERIOR FOUNDATION CORNERS. 4. PROVIDE AND MAINTAIN POSITIVE DRAINAGE AWAY FROM ALL FOUNDATION WALLS PER WARRANTY REQUIREMENTS. (0.5% MINIMUM SLOPE FOR CONCRETE PANS.) S. THIS PLOT PLAN SHOWS PROPOSED IMPROVEMENTS ONLY. FINAL CONSTRUCTION MAY VARY. 6. FOR QUESTIONS REGARDING THE FOUNDATION DURING EXCAVATION, FORM SETTING, AND HOUSE CONSTRUCTION REFER TO THE ENGINEERED FOUNDATION PLANS. 7. BEFORE STAKING, THE BUILDER SHOULD VERIFY ALL HOUSE PLAN NUMBERS, DIMENSIONS, ELEVATIONS, AND SETBACKS TO THE PLOT PLAN. IF ANY DISCREPANCY EXISTS PLEASE CONTACT APPROPRIATE PERSON. 8. DRIVEWAY SQUARE FOOTAGE CALCULATION IS BASED ON FOLLOWING ASSUMPTIONS: —W1DTH�17.0'. LENGTH=FACE OF GARAGE TO BACK OF WALK. —AREA IN RIGHT OF WAY IS QUANTIFIED SEPARATELY. THIS IS A BASIC CALCULATION AND IS NOT AN ESTIMATE OF EXACT QUANTITIES REQUIRED. L'- z 0x Inw LJ 0 0 LOT 113 R/BOW FOW 9961 _x = E/BOG PLOT PLAN CHECKED —6J It III L� MT. DATE OVER EX. CHECKEDy0. INIT. DAIS DO NOT STAKE CKO NIT. DATE R.QM. IF APPLICABLE R714. oATe • LOCATE WATER METER PIT, LIGHT /y POLE OR ANYTHING ELSE THAT MAY ®q � � f,.! • AND CAUL OFFRCE, WAY LOCATION lu MINIMUM, SETBACKS: \CALL Carroll & Lange us UTILITY NOTIFICATION CENTER OF COLORADO FRONT: 15 Prolessionel Engineers&Land Surveyors 1-800-922-1987 REAR: 8' Soot. Union do 8 28 156 Lakewood. 80228 OR 534-6700 1DENVER SIDE: 5 ST. SIDE: 15 (303)980-02Orada (303) 980-0200 CALL SYUDN��AT9[Op GRADOR "CE FM ME m"IdW or UI0ILPw1DUND MIN. BETWEEN • MCMYER VTIUTIES STRUCTURES: 10' FbEL NOTES: BOW HI TGB ELEV HUB ELEV HUB + ELEV HI FUL— CHECK IN / HSE STK BY DATE HSE RESTK BY DATE FDN BY DATE ISP/GRD BY DATE NBW/GRO BY DATE REORO DY DATE REGRD BY DATE LEGEND: (L'=PROPERTY LINE BOW=BACK OF WALK FOW=FRONT OF WALK FL=FLOW LINE EASEMENT - — — - SETBACK SCALE: 1 11=20' DATE: 11-22-06 FRO REV: REV: JOB NO: 2686