HomeMy WebLinkAbout2309 Flagstaff Pl - Site Plans/Single Family New - 11/20/2006PLOT PLAN FOR ENTEX HOMES AVIDAVIT OF CORRECTION: LOT 1Q BLOCK 2 SUBDIVISION. LIND PROPERTY FILING NO. 1 CITY OF FORT COLLINS COUNTY OF LARIMER STATE OF COLORADO ADDRESS 2309 FLAGSTAFF PLACE -CARROLL & LANGE RECOMMENDS A LOT INVENTORY BEFORE STAKING HOUSE- 6' WOOD FENCE W/ STONE COLUMNS (TYP) TRACT "A" J2,7 33.5 33.4 31.6 31.9 80.36' N9000'00"W 34.3 6'DE 33.1 LOT 10 _BLOCK 2 N~ a a 6, 094±S.F N 30.J4d. ^ 31.1 M1/1 N � N2X cli N H� / Y LOT 11 BLOCK 2 R/BOW FO W FL 0 29.4 I✓T - ---- 31--7/ SfODP 32.5 2.5 330.1 -� 7'0' cvn / f\ 1\ _44O I 31.7 3CRAWIL 31.7 I p ?SB• / I(^') I I I 30.7 ?X 29.3 ;W �I N PLAN H-2 N I Q 29.2 31.8 111 ELEV 38 2.4 o <c 2 I it 111to _ 200 BSMT ' I II oI STEP LO' / / 0� 30.8 / 30.7 \29.z 1 i( a I 2 CAR 6.0' 3ARAGE N I z x 28.9 \ 29.0 I I OF ® 01 p 20.0' I 3/ 7.0 12.0' 29.4 29.5 cY30.4 29.4 29.0 1 n / Q 9'DE&UE 28.1 28.2 L=44.48' R=75.50' a=3345'28" FLAGSTAFF PLACE 80605719 NOTE: SANITARY SERVICE INVERTS WERE CALC USING AS -BUILT MANHOLE INFORMATION PROVIDED BY STANTEC CONSULTING INC. GENERAL NQIM I. THIS PLOT PLAN DOES NOT SHOW LOCATION OF VANDOW WELLS. FOR THEIR LOCATION SEE STRUCTURAL ENGINEERED PLANS, 2. THIS PLOT PLAN IS BASED ON INFORMATION PROVIDED TO CARROLL k LANGE BY THE BUILDER / DEVELOPER. 3. DIMENSIONS SHOWN AROUND THE PERIMETER OF THE STRUCTURE ARE TO THE EXTERIOR FOUNDATION CORNERS. 4. PROVIDE AND MAINTAIN POSITIVE DRAINAGE AWAY FROM ALL FOUNDATION WALLS PER WARRANTY REQUIREMENTS. (0.5X MINIMUM SLOPE FOR CONCRETE PANS.) 5. THIS PLOT PLAN SHOWS PROPOSED IMPROVEMENTS ONLY. FINAL CONSTRUCTION MAY VARY. 6. FOR QUESTIONS REGARDING THE FOUNDATION DURING EXCAVATION, FORM SETTING, AND HOUSE CONSTRUCTION REFER TO THE ENGINEERED FOUNDATION PLANS. 7. BEFORE STAKING, THE BUILDER SHOULD VERIFY ALL HOUSE PLAN NUMBERS. DIMENSIONS, ELEVATIONS, AND SETBACKS TO THE PLOT PLAN. IF ANY DISCREPANCY EXISTS PLEASE 30.4 0 LOT 9 BLOCK 2 Desmond P Scott G "an6 N Linda S Tdsia 8 HOMEOWNER ACCEPTANCE: LOT CORNER ELEVATIONS SHOWN HEREON HAVE NOT BEEN FIELD VERIFIED AT THIS TIME. ACTUAL SITE GRADING MAY DIFFER FROM THIS DESIGN. LEVEL NOTES: Bow RI SANITARY SEWER INVERT NOTES: ELEV TGB=32.4 UB E EEV RUB ♦ VLEV BSMT HT=10.0' " ONECK IN RLL� TOTAL=22.4 HSE SIX BY DATE HSE RESTIK BY DATE STUB IN INV=14.9 FDN ISPOLD oATTE - CLEARANCE=7.6 HIT REOM By. ; BY DATE LL .. • LOCATE WATER METER PIT, LIGHT POLE OR LEGEND: 0 K 1n W ANYTHING ELSE THAT MAY AFFECT THE DRIVEWAY LOCATION AND CALL OFFICE. R=PROPERTY LINE - -EASEMENT Oz BOW -BACK OF WALK -SETBACK Z U FOW=FRONT OF WALK (� =ELEVATION ADJUSTING FL=FLOW LINE NUMBER ,\EIAIUTIUTYLITY CarrollLan e = NOTIFICATION OF COLORADOg MINIMUM SETBACKS: SCALE: 1'=20' -922-1987 DATE:11-17-06 FRO Protsaslowl Engineers a Lend Sumyon Sou,n Union BIVd.. suite 156 LeKewood. Goioreso 80226 534-6700 FRONT: 20'-GAR 15'-FND185 . .,REV: ]� SIDE: `� STREET SIpE:15.REV: (303) 980-0200 Etao DENVBRREAR: oAn IN AwuleL were MIN BTWN STRUCTS: ].QTE, a uCAVATc roR THEJOB �4wl D m m ummu NO:3648