HomeMy WebLinkAbout245 Cajetan St - Special Inspections/Engineering - 02/20/2006Footine Ouality Assurance Observation
Per the clients request, a representative of SECURE has visually
observed the footing forms under construction at the site referenced
below. The following summarizes our observations and opinions at the
time of our visit.
SECURE
CONSULTING ENGINEERS
Client: /4nel Site Address:
Secure Job #• � �� �� �c •� _
Sib.S' - 9 h/ Lot: _�/ Block: � Filing:
Date: s e Contact: Q.QZ r Subdivision:
Foundation Plan Information
Plan By: ,, /mac'
Date:i v/ IkT Job#:
Ftgsizes: , )4-' , 2y''
Pad sizes :
-5 (d
Concrete on site? ❑ yes, X no, (+/- % ftg poured b /1)
Are the footing forms free of loose material, frost, water and
or ice, roots, etc? X yes , ❑ no
Are the Footing / Pad form sizes in general conformance to
the above foundation plan? lgyes, ❑ no
Is the footing/pad reinforcing steel in -place or on site per the
above foundation plan? Jig yes, ❑ no
Weather: wooy — 3Sol
Notes:
r is rpwA. a_ ,
Summary of Opinions
JA It is our opinion that the footing formwork is in
general conformance with the foundation design
referenced above.
❑ It is our opinion that the footing formwork differs
significantly from the foundation design referenced
above (2nd observation required).
Corrective action:
Reinforcing Steel Quality Assurance Observation SECUIVE,
Per the clients request, a representative of SECURE has visually CONSULTING ENGINEERS
observed the reinforcement within the formwork under construction at
the site referenced below. The following summarizes our observations
and opinions at the time of our visit. IF A CTL I THOMPSON COMPANY
Client: /% r!, ,. ;1.� .,,: Nc Site Address: 2y5d
Secure Job #• Lot h Block: +Filing-
Date:n _
o6 Contact: i B_�
�% ��•-�� Subdivision:T�--
Reinforcine Plan Information
Plan By: f1c.Qe
Date: i?�o. oS Job#:
Reinforcing Type(s):
❑ footing .dfoundation wall
❑ grade beam ❑ pier cap
❑ structural slab ❑ slab -on -grade
❑ column ❑ other
Wall / Grade Beam Reinforcine Steel
rz.
Vert./Ties
N
7P
*W62
Pier Can / Slab Reinforcine Steel
Lateral
A
B
7C
DEGradeLongitudinal
UFER Ground
,' Installed - Location
❑ Not Observed
Max / Min wall height observed:
If void forms are required, are they installed as
recommended? .0
❑ yes , ❑ no Required thickness: in.
Concrete on -site? ❑ yes Lino (% poured = +I_ -0Z)
Weather:, —
Notes:
Summary of Opinions
It is our opinion that the reinforcing steel observed
was in general conformance with the plan.
❑ It is our opinion that the reinforcing steel observed
was not in general conformance with the plan.
(2"d observation required).
Deficiencies
Secure Foundations, LLC 0 211 West Magnolia Street, Ft. Collins, CO 80521 0 Ph: 970-472-6255 0 Fax: 970-472-6256
Perimeter Drain / Dampproofing Quality SECU
Assurance Observation
Per the clients request, a representative of SECURE has visually CONSULTING ENGINEERS
observed the perimeter drain and/or dampproofing at the site referenced
above. The following summarizes our observations and opinions at the A CTL I THOMPSON COMPANY
time of our visit.
Client: Palladian Homes, Inc. Site Address: 245(aietan fr eP
P.0- Rnx 2700S3,Fort Col hin Cn F� Cntl I ins C,0
Secure Job # 34 Lot: �_ Block q Filing:
Date: 03laioa Contact: br12 G ardnPr Subdivision: S)Igi Town North
Project Specifications
Foundation Plan By: 5eure
Date 03/22/05 Job# SF05-934
Geotechnical Report By: TerraLCon
Date 12/ 19 /170 Job# 20005251
Recommended Drain type?
❑ Exterior perimeter (9/Interior
❑ other
Observations
Pe 'meter drain observed around:
f� Basement ❑ Crawlspace
❑ Other:
Where does the pf rimeter drain discharge?
❑ Daylight I� Sump pit ❑ Subdivision drain
Dp mpproofing observed around:
u Basement ❑ Crawlspace ❑ All backfill areas
Comments
-}
Garda
J
t
- ..G 1
4-
.
r2.•.
t-j—,..r } '. '_. ttldilates {a( 1m7nit(a[f; draltt locat40R
:. a;. i
SUmmary of Opinions
It is our opinion that the foundation drain and/or
dampproofing observed generally conform with the
project referenced above.
❑ It is our opinion that the foundation drain and/or
dampproofing observed differs significantly form the
project specifications (2nd observation required).
Corrective Action:
Secure Foundations, LLC • 211 West Magnolia Street, Ft. Collins, CO 80521 • Ph: 970-472-6255 • Fax: 970-472-6256
Compaction
Test Report
CLIENT: PALLADIAN HOMES
P.O. BOX 270053
FORT COLLINS CO 80527
as INCORPORATED
DATE: (IR/14/nR
Phase: 330 REPORTNUMBER:
SUBJECT: OLD TOWN NORTH
PROJECT NUMBER: F A371 2 non
SHEET: I_ OF _ i
N. COLLEGE AVE. AND CONIFER ST.
FORT COLLINS, CO
FOUNDATION WALL BACKFILL
245 CAJETAN STRFFT
TEST
1
LABORATORY
FIELD
NO.
LOCATION
DEPTH
TEST
T
TYPPCF
PACOT —
SOIL TYPE
MAX
DENSITY
OMC%
DRY DENSITY
MC%
FEET
PCF
%
CURVE NO
7
10' N OF SW CORNER OF GARAGE
0.0
NUC
113.0
16.0
102.0
15.1
90
JOB NO FC03712.000
CURVE NO 1
8
10' N OF SE CORNER OF GARAGE
0.0
NUC
113.0
16.0
104.0
14.4
92
JOB NO FC03712.000
CURVE NO 1
9
� RFi nw
NE CORNER OF BASEMENT
raeno
0.0
NUC
113.0
16.0
104.0
16.2
92
JOB NO FC03712.000
SPECIFICATIONS: 90 % MAXIMUM ASTM D 698
MOISTURE WITHIN TO % OPTIMUM
TYPE OF COMPACTION EQUIPMENT AND NO. OF UNITS:
NOT OBSERVED
MOISTURE ADDED BY NOT OBSERVED
TYPE OF EARTH MOVING EQUIPMENT AND NO, OF UNITS:
NOT OBSERVED
THIS REPORT PRESENTS OPINIONS FORMED AS A RESULT OF
OUR OBSERVATION OF FILL PLACEMENT, AS WELL AS THE TESTS
SHOWN ABOVE, WE HAVE RELIED UPON THE CONTRACTOR TO
APPLY THE NECESSARY COMPACTIVE EFFORT AND MOISTURE
TO ACHIEVE SPECIFIED COMPACTION DURING TIMES WHEN OUR
OBSERVER IS NOT PRESENT, AND AT LOCATIONS OTHER THAN
THOSE TESTED. TEST DATA ARE NOT THE SOLE BASIS FOR
OPINIONS ON WHETHER THE FILL MEETS SPECIFICATIONS.
THICKNESS OF LIFT
INCHES
PROGRESS REPORT
AS REQUESTED BY DOYLE GARDNER WITH PALLADIAN HOMES, A SITE VISIT WAS MADE ON 6/14/06 TO
OBSERVE AND TEST FOUNDATION WALL BACKFILL AT 245 CAJETAN STREET. THE BACKFILL WAS
PLACED PRIOR TO OUR ARRIVAL. THREE LOCATIONS WERE SELECTED BY US FOR TESTING. WE
INFORMED THE CONTRACTOR RESULTS FOR TESTS PERFORMED AT THE LOCATIONS DESCRIBED ABOVE
WERE WITHIN SPECIFIED LIMITS. OUR OFFICE WILL BE CONTACTED WHEN ADDITIONAL TESTING IS
REQUESTED.
a IN OUR OPINION, FILL COMPACTION MEETS SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) 7-9
❑ IN OUR OPINION, FILL COMPACTION DOES NOT MEET SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S)
SCOPE OF FULL OBSERVATION: ❑ TIME; ❑✓ PERIODIC, ON CALL BASIS; ❑✓ ADVISEDCTOR'S OR CLIENTS REPRESENTATIVE KI, .t 1
/����G mil/. r/�j/�IRLLAD HOfiAE
FREDERICK BRAUN �i /_ " G
FIELD REPRESENTATIVE CTLITNOMPSON, INC. � (d P
APPROVED BY ERIC BERNHA T,,•PE
MANAGER OF 4LV'SERVICEB'
4001 Automation Way I Suite 201 1 Fort Collins, CO 80525 1 Phone: 970-206-9455 1 Fax: 970-206-9441