Loading...
HomeMy WebLinkAbout3815 Steelhead St - Special Inspections/Engineering - 12/06/2005December 6, 2005 Chateau Development Company 12050 Pecos Street, Suite 100 Westminster, Colorado 80234 Attn: Mr. Doug Barkus Re: Testing Summary Building 16 3815 Steelhead Street Brookfield, Phase 1 Fort Collins, Colorado EEC Project No. 1025015L Mr. Barkus: �a so a E[E7 EARTH ENGINEERING CONSULTANTS, INc. We have recently been asked to provide a summary of the construction observation and testing services performed for the referenced project. A summary of the testing completed is included with this letter. As you are aware, Earth Engineering Consultants, Inc. (EEC) personnel observed and tested site concrete, overlot grading materials, utility installation backfill and subgrade and surfacing for concrete and asphalt paving. The testing and observation services were performed on a part- time, on -call basis during the various operations. The final test results for the backfill and subgrade materials met the project compaction and moisture requirements for the materials being prepared or placed. The concrete test results met the project specification for compressive strength. The specific test results were provided at two -week intervals during site construction. We appreciate the opportunity to be of service to you on this project. If you have any questions concerning this report, or if we can be of further service to you in any other way, please do not hesitate to contact us. Very truly yours, Earth Engineering Consultants, Inc. Brian D. Thomas Project Manager 4396 GREENFIELD DRIVE WINDSOR, COLORADO 80550 (970) 224-1522 FAX (970) 663-0282 August 18, 2005 Chateau Development Company 12050 Pecos Street, Suite 100 Westminster, Colorado 80234 Attn: Mr. Doug Barkus Re: Construction Observation and Testing Brookfield, Phase I — 3815 Steelhead Fort Collins, Colorado EEC Project No. 1025015L Mr. Barkus: RECEIVED AUG 312005 C EARTH ENGINEERING CONSULTANTS, INc. Earth Engineering Consultants, Inc. (EEC) personnel have completed the construction observation services you requested for the referenced project. Those services included the observation of reinforcing steel for the garage stem walls. On August 11, 2005, EEC personnel observed reinforcing steel consisting of one #5 rebar continuous through the garage area footings with two #5 bars at garage openings. At the time of our observations, it appeared that the reinforcing steel had been placed in general accordance with the construction drawings. We appreciate the opportunity to be of service to you on this project. If you have any questions regarding this report or if we can be of further service to you in any way, please do not hesitate to contact us. Very truly yours, Earth Engineering Consultants, Inc. Brian Stribley E.I.T. Project Engineer Reviewed by: Lester L. Litton, P.E. Principal Engineer 4396 GREENFIELD DRIVE WINDSOR, COLORADO 80550 (970) 224-1522 FAX (970) 663-0282