Loading...
HomeMy WebLinkAbout6200 Pheasant Ct - Special Inspections/Engineering - 09/22/2006September 22, 2006 Michael & Cheri Scimeca 6200 Pheasant Court Fort Collins, Colorado 80525 RE: Beam Repair & Joist Pass Through Requirements 6200 Pheasant -Court Fort Collins, Colorado 80525 Terracon Project No. 20066074 Irerracon Consulting Engineers & Scientists Terracon Consultants, Inc. 301 North Howes Fort Collins, Colorado 80521 Phone 970.484.0359 Fax 970.484.0454 www.terracon.com Terracon Consultants, Inc. understands that a 2-ply 1-3/4 inch by 9-1/2 inch Laminated Veneer Lumber beam, located in the basement of the above referenced residence and spanning north to south, was notched and needs additional support. Approximately 12 inches from the north end of the beam, a 3-1/2 inch deep by 32 inch long notch was cut into the underside of the beam. One 3/8 inch steel plate was secured to the east side of the beam using (6) 112 inch diameter bolts. Terracon Consultants, Inc. has determined that the following additional support is required for the beam. One additional 318 inch thick steel plate, identical to the existing steel plate, shall be secured to the east side of the beam. The second steel plate shall be secured to the first plate and the LVL beam using the existing (6) 1/2 inch diameter bolts; three additional 1/2 inch diameter bolts should be added above the notched portion of the beam, equally spaced. The floor joists shall be secured to the beam using (2) 3 inch long screws, one on each side of the bottom flange. The flanges of the floor joists shall be pre -drilled to avoid splitting the flange. Each joist shall be secured to the beam, the entire length of the beam. Terracon Consultants, Inc. understands that the owner wishes to cut a pass through in the joists supporting the main floor. Manufacturer specifications allow the following round hole size for 9-1/2 inch floor joists: Joist Size Round Hole Size Minimum Distance from Bearing 2„ 3" 1,_6., 4" 2'_0" 5" T-0„ 6" 5'-On Delivering Success for Clients and Employees Since 1965 More Than 70 Offices Nationwide Beam Pocket & Window Lintel Repair 6200 Pheasant Court Fort Collins, Colorado 80525 Terracon Project No. 20066074 Ire can This letter was prepared for the exclusive use of our client and is not intended for any other purpose. Our report is based on the information made available to us at this time. Should additional information become available, we reserve the right to determine the impact, if any, of the new information on our opinions and conclusions, and to revise our opinions and conclusions if necessary and warranted by the discovery of additional information. If you have any questions about the information contained in this letter, please contact us. Sincerely, TERRACON M. Mae Benvenga, E.I.T. Project Manager/Structural Engineer Copies to Addressee: 2p -2- tiR.QaGo�O o cy o � I ON P\- 7f(fllltttt�� Ken Rollin, P.E. Structural Engineer