HomeMy WebLinkAbout714 Gilgalad Way - Disclosures/Other - 05/28/1997Fort Collins residential energy code 7/96
Insulation disclosure form
Job Address: 714 Gilgalad Way
General Contractor: Dana McBride
Insulation Contractor: Thermal Concepts Insulation
P.O. Box 270066
Fort Collins, CO 80522
970-223-7090
s Ia, `on
M
Rated
Location
Location
Material(s)
Thickness
R-value
(Int/Ext)
Notes
Fiberglas
—
Flat or vaulted ceilings with
�
attics above
Ceilings with enclosed rafter
Kraft FG t
v
' ' ` "'''
Kraft FG Batts
9 tr
30
"i 'slopes
cavities
di44
_.
_
m4 9A
Frame walls and rim/band
Poly
3 e
15
joists -to exterior
'•a'.
6
r -
Frame walls and rim/band
Fi las batts
6"
19
joists -to aitic,garage
a^ „ � sy,
a
a�z a
Frame floor -cantilever
°
FiberqlaS bat'h5
9Y,
30
Frame floor -over garage or
crawl space.
e
Nu., kn
Slab -on -grade (0-12')
NZA
N/A
Crawl space walls
n
Basement walls
Maft FG Batts
3 "
11
Foam doors, tairrl
Foam sealant
baseres>t taht are op
m to outside.
�.
t.
I/We certify that the above listed insulation in the building at the above locations in conformance with the current requirements of the City of Fort Collins
Residential Energy Code, and that it was installed in accordance with the applicable "Insulation Installation Guidelines" published by the City of Fort Collins.
Certified by: Thermal Concepts Insulation
Business firm: Thermal Concepts Insulation
Address: 6617 S. College Ave.
Phone: 970-223-7090
I. -
Signature:
This disclosure for is to be signed by the insulation contractor or representative of the general contractor.
Please type or print, except for the signature.
If components vary, make multiple entries to describe them.
One copy of this form shall be provided to the Building and Zoning Department at final inspection.
One copy of this form shall be provided to the home buyer.
r.,. Fort Collins residential energy code V96
Mechanical systems disclosure form i
Job address:
General contractor.
?L ;nc�ntc 2, contractor.
tg system
!
Input capacity
AFUE or
LOC30on
Fuel
Type
Manufacturer
Model #
ketuh or kW
HSPF
/ '
C% . '�h✓
`, ff.r00(
n
r.
v
";race cooling system .
Lccatlnn
Fuel
Type
Manufacturer
Model #
Input capacity
ketuh or kW
SEER
heating system
t
i :r r(V
Fuel
Tv
Manufacturer
___Model # 4
Input capacity
kBtuh or kW
Energy 1 st rag%
Factor velum;_
a1K5
fOITP
F5 5b ti32
«4f . ,oc:e-listed equipment was Instatied in the building at the above locations in conformance with the
st. ,ra t rvgwremen ,of the City of Fort Collins Residential Energy Code and Mechanical Code, and that it was installed in
acemc:ance w,th manufactures s instructions. Uwe certify that any ductwork has been installed in confo(mance with
Fw, current requirements of'J)e Cityof FortCollins Residential Energy Code and Mechanical Code.
Certified by: kobert Miller Phone; 97/0-223-8873
Businessflrm: Northern Colorado Air, lndJate:
Address: 1823 ;. Harmony xd. Signature: {
ri; s disclosure form ;s to be signed by the mechanical contractor or representative of the general contractor,
S'I�;ase type or prink excepttor the signature.
,7era are multiple systems serving any function, make multiple entries to describe them.
C:t•a Ccpr of :his form shalt be provided to the Building and Zoning Department at final inspection.
,rcns,c W in53} _ �VK
copy cf this form shall be provided to the homebuyer.
0