ENGINEER'S FIELD REPORT
Report Date: November 2, 2000
Report No.: 2
Project: James Company Sage Creek Townhomes
Location: 3051 Sage Creek Road, Unit D-Garage, Fort Collins, Colorado
Architect: J. W. Miller Associates, Longmont, Colorado
Contactor. James Company, Boulder-, Colorado -(Scott Holmes) -
Subject: Concrete Foundation Walls
Date: November 2, 2000 (2:30 pm) Weather: Seasonal
OBSERVATIONS
In general, the size, type and placement of the reinforcing steel are consistent with the structural
requirements outlined in the foundation plan. The horizontal reinforcement consists of No. S,
Grade 40 steel, while the vertical reinforcement was No. 4, Grade 60 reinforcing bar. All
observed steel reinforcement was tied together properly, with lops at splices and corner bars being
24 inches minimum in length.
FIELD INSTRUCTIONS GIVEN
Instructed Foreman to supply horizontal and vertical reinforcement at all wall portions between
blockouts.
cc: File
PLAZA ENGINEERING CONSULTANTS, INC.