HomeMy WebLinkAbout2700 Garrett Dr - Special Inspections/Engineering - 02/22/1989FOUNDATION II Consulting ENGINEERING Engineers ,February 22, 1989 Commission No. 1106-01-07-01 Jensen Homes 2601 Yorkshire Fort Collins, Colorado 80526 Re: 2700 Garrett (Permit No. 890026) Gentlemen: We have observed the hip framing at the above referenced project. This inspection was performed on February 22, 1989. It is our opinion that the framing as constructed is adequate to support all code live loads and dead loads of which it will be subject to, with the following ex- ception. We recommend solid blocking the trusses at the ridge a minimum of three trusses back from all hips to allow distribution of hip loads into the roof diaphragm. .Blocking should be well glued and nailed to,the deck. If you have any questions, please call, Res K Fou KWP 320 North Cleveland Avenue Loveland, Colorado 80537 (303) 663-0138