Loading...
HomeMy WebLinkAbout2103 Falcon Hill Rd - Disclosures/Final Energy - 12/02/2000Dec 06 00 08:48a SFRR (970) 266 - 1009 p.2 DATE 12/02/00 SARA'S ENERGY SCORING 2115 WATER BLOSSOM LANE FT. COLLINS CO 80526 (970) 266-1009 CUSTOMER: Pete Sherman 2103 Falcon HIll Rd FORT COLLINS BUILDING CONDITIONS: interior Temp = 66 F Exterior Temp = 55 F volume = 22025 Cu. Ft. Above Grade Surface Area - 0 Sq. Ft. Number of Stories = 1 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 58 141 2069 -0.1 Ring A 54 114 1863 -1.2 Ring A 46 79 1554 1.9 Ring A 40 54 1287 1.6 Ring A 34 33 1009 -1.2 Ring A 28 19 768 -2.8 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9988 C = 9.50 n = 1.326 Results: Air Flow @ 50 Pascals : 1702 CFM50 +/- 0.7% .4.64 ACK50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 16.94 Square Inches +/- 8-396 Equivalent Leakage Area (CANADA) 59.14 Square Inches +/- 5.3% Estimated Natural Infiltration (50 Pascal Flow Divided By 17.0) = 100 CFM = 50.1 CFM/OCCUPANT = 0.27 AIR CHANGES PER HOUR