HomeMy WebLinkAbout2103 Falcon Hill Rd - Disclosures/Final Energy - 12/02/2000Dec 06 00 08:48a SFRR
(970) 266 - 1009 p.2
DATE
12/02/00
SARA'S ENERGY SCORING
2115 WATER BLOSSOM LANE
FT. COLLINS CO 80526
(970) 266-1009
CUSTOMER: Pete Sherman
2103 Falcon HIll Rd
FORT COLLINS
BUILDING CONDITIONS:
interior Temp = 66 F Exterior Temp = 55 F
volume = 22025 Cu. Ft. Above Grade Surface Area - 0 Sq. Ft.
Number of Stories = 1 Number of Occupants = 2
Wind Shield Factor = 1
HOUSE TEST : Depressurized
Fan Model = 3
Performed By SARA
Data Points:
House Pressure
Fan Pressure
CFM
%Error
Fan Configuration
58
141
2069
-0.1
Ring A
54
114
1863
-1.2
Ring A
46
79
1554
1.9
Ring A
40
54
1287
1.6
Ring A
34
33
1009
-1.2
Ring A
28
19
768
-2.8
Ring A
Correlation Coefficient
Flow Coefficient
Exponent
r = .9988
C =
9.50
n = 1.326
Results:
Air Flow @ 50 Pascals :
1702 CFM50 +/- 0.7%
.4.64 ACK50 (Air Changes Per Hour)
Effective Leakage Area (LBL) = 16.94 Square Inches +/- 8-396
Equivalent Leakage Area (CANADA) 59.14 Square Inches +/- 5.3%
Estimated Natural Infiltration (50 Pascal Flow Divided By 17.0)
= 100 CFM
= 50.1 CFM/OCCUPANT
= 0.27 AIR CHANGES PER HOUR