HomeMy WebLinkAbout2039 Falcon Hill Rd - Disclosures/Final Energy - 12/02/2000Dec 06 00 08:48a SARR (970) 266 - 1009 p.1 SARA'S ENERGY SCORING 2115 WATER BLOSSOM LANE DATE FT. COLLINS CO 80526 12/02/00 (970) 266-1009 CUSTOMER: Pete Sherman 2039 Falcon Hill Rd FORT COLLINS BUILDING CONDITIONS: Interior Temp = 66 F Exterior Temp = 55 F Volume = 22025 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 1 Number of Occupants = 2 Wind Shield Factor 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Pan Pressure CFM %Error Fan Configuration 56 120 1910 0.5 Ring A 53 100 1746 -1.0 Ring A 46 70 1463 0.7 Ring A 41 50 1239 -0.2 Ring A 32 25 879 -0.6 Ring A �7 16 705 0.6 Ring A Correlation Coefficient Flow Coefficient Exponent r = _9997 C = 7.74 n = 1.367 Results: Air Flow 0 50 Pascals : = 1628 CFM50 +/- 0.3% 4.43 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 14.61 Square Inches +/- 4.1% Equivalent Leakage Area (CANADA) 52.95 Square Inches +/- 2.6$ Estimated Natural Infiltration (50 Pascal Flow Divided By 17.0) 96 CFM = 47.9 CFM/OCCUPANT 0.26 AIR CHANGES PER HOUR