Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
901 Somerly Ln - Disclosures/Final Energy - 09/08/1998
City of Fort Collins ENERGY SCORE Home Energy Rating Program - Version 2.0.4 ******************************************************************************* ENERGY RATING RESULT FINAL ***********************************************************VTE RATE******* Owner: ABD 60w1C-f, L`1 Address: 901 SGMMERt-'f- Zip: 80526 Phone: 225-2323 Builder: ABD Model: 901 SOMMERLY Devel: Reference #: 241001 Data File: A:901-SOMM.DAT Run Date: 09-08-1998 Year Built: 1998 Rating Firm: RICHMOND ASSOCIATES Site Rater: DONALD RICHMOND Rating Date: 9-8-98 ******************************************************************************* ENERGY SCORE: *********** * G - 83 *********** G - 83 v v (Least -------------------------------- ---- I ---- I Efficient) G-0 10 20 30 40 50 60 70 80 90 100 (Most Efficient) ******************************************************************************* This program is offered by the City of Fort Collins as an aid in comparing the energy efficiency of homes. The information provided does not constitute any warranty, express or implied, as to the presence or lack of energy features in this house, the heating fuel used in the house and its costs, or the actual energy consumption or performance of the house. City of Fort Collins ENERGY SCORE Home Energy Rating Program - Version 2.0.4 DETAILED ENERGY REPORT FOR RATED BUILDING Owner: ABD Address: 901 SOMMERLY Zip: 80526 Phone: 225-2323 Builder: ABD Model: 901 SOMMERLY Devel: BUILDING CHARACTERISTICS Conditioned Space Area: 3996 sq ft Total Glazing Area: 314 sq ft Air Infiltration Rate: 0.40 AC/h Eff. Thermal Capacity: 8631 Btu/F Util. of Direct Solar: 0.68 BUILDING ENERGY SUMMARY Reference #: 241001 Data File: A:901-SOMM.DAT Run Date: 09-08-1998 Year Built: 1998 Rating Firm: RICHMOND ASSOCIATES Site Rater: DONALD RICHMOND Rating Date: 9-8-98 ENERGY SCORE *********** * G - 83 *********** Load Efficiency Energy Consumed Fuel Cost Energy Cost KBtu/sf o KBtu/sf MMBtu $/MMBtu $/sf Gas Space Heat 19.7 80.0 24.7 98.5 4.24 0.10 Gas Water Heat 6.1 54.0 11.3 45.0 4.24 0.05 Building TOTAL 25.8 35.9 143.5 0.15 COMPONENT SUMMARY: SPACE HEATING Heat Loss Coeff Gross Heat Loss Useful Gains Net Heat Load --------------- Btu/hr-F --------------- % KBtu/sf ------------ o KBtu/sf o ------------- KBtu/sf MMBtu Ceilings/Roofs 46.5 6 1.8 6 0.4 5 1.4 5.7 Frame Walls 121.1 17 4.7 14 0.4 5 4.3 17.2 Masonry Walls 9.9 1 0.4 1 0.1 1 0.4 1.4 Rim/Band Joists 10.0 1 0.4 1 0.0 0 0.4 1.6 Windows/Skylights 176.3 25 6.9 21 4.5 54 2.4 9.6 Sunspace - - - - - - - - Doors 13.9 2 0.6 2 0.0 0 0.6 2.2 Foundation Walls 81.1 11 3.2 10 0.0 0 3.2 12.6 Frame Floors - - - - - - - - Slab Floors 52.9 7 2.1 6 0.0 0 2.1 8.2 Crawl Sp/Unht Bsmt - - - - - - - - Infiltration 206.9 29 8.1 25 0.0 0 8.1 32.3 Envelope TOTAL 718.5 100 28.0 85 5.3 64 22.7 90.8 Active Solar Spc Ht - - - - - - Internal Gains 0.0 0 3.0 36 -3.0 -11.9 Duct/Pipe Losses - - - - - - Furnace Losses 4.9 15 0.0 0 4.9 19.7 Space Heating TOTAL 33.0 100 8.3 100 24.6 98.5 COMPONENT SUMMARY: WATER HEATING Gas 11.3 KBtu/sf = 45.0 MMBtu Solar - - Water Heating TOTAL 11.3 KBtu/sf = 45.0 MMBtu ENERGY SCORE Data Listing Input Worksheet: A:901-SOMM.WS Date: 09-08-1998 Reference Number: 241001 1. GENERAL INFORMATION Property Owner's Name Property Address Zip Code Telephone Number(s) Home Builder's Name Model Name or Number Development Name Energy Rating Company Building Plan Rating: Energy Rater's Name Energy Rating Date Site Visit Rating: Energy Rater's Name Energy Rating Date 1 ABD 2 901 SOMMERLY 3 80526 4 225-2323 5 ABD 6 901 SOMMERLY 7 8 RICHMOND ASSOCIATES 9 DONALD RICHMOND 10 6-29-98 11 DONALD RICHMOND 12 9-8-98 Year Constructed 13 1998 Area of Conditioned Space (sq ft) 14 3996 Housing Type (1-5) 15 1 Apartment Only: Level Type (1-3) 16 0 Floors On or Above Grade (1-2) 17 2 Foundation Type(s) (1-7) 18 4 Roof Entry Line # [191 [201 [211 3. CEILINGS/ROOTS Gross Area (sq ft) 19a 1998 20a 0 21a 0 Ceiling/Roof Insulation (R-Value) 19b 40 20b 0 21b 0 Ceiling Type (1-2) 19c 1 20c 0 21c 0 4. RIM AND BAND JOISTS Area Joist Location Joist Insulation (sq ft) (1-4) (R-Value) 22a 179 22b 1 22c 19 23a 39 23b 2 23c 19 5. FRAME OR BRICK VENEER WALLS Wall Entry Gross Area Wall Location Wall Insulation Line # (sq ft) (1-4) (R-Value) [241 24a 1790 24b 1 24c 16 [251 25a 390 25b 2 25c 13 [261 26a 0 26b 0 26c 0 (271 27a 0 27b 0 27c 0 ENERGY SCORE Data Listing Input Worksheet: A:901-SOMM.WS Date: 09-08-1998 Reference Number: 241001 6. MASONRY WALLS ABOVE GRADE Wall Entry Gross Area Const. Type Wall Location Wall Insulat Line # (sq ft) (1-4) (1-4) (R-Value) [281 28a 89 28b 1 28c 1 28d 13 [291 29a 20 29b 1 29c 2 29d 13 [301 30a 96 30b 1 30c 1 30d 13 7. WINDOWS (INCLUDING DOOR GLAZING) Area Orientation Glazing Type Wall Entry (sq ft) (1-6) (1-21) Line #(24-30) 31a 64.8 31b 3 31c 4 31d 24 32a 53.7 32b 1 32c 4 32d 24 33a 58.7 33b 3 33c 4 33d 24 34a 45.6 34b 5 34c 4 34d 24 35a 32.5 35b 3 35c 4 35d 24 36a 14.7 36b 5 36c 9 36d 30 37a 14.7 37b 3 37c 9 37d 30 38a 29.4 38b 1 38c 9 38d 30 9. DOORS (OPAQUE DOOR AREAS ONLY) Area Door Insulation Storm Door Wall Entry (sq ft) (R-Value) (l.yes, 2.no) Line #(24-30) 43a 20 43b 4.4 43c 2 43d 24 44a 17.8 44b 1.7 44c 2 44d 25 45a 8.8 45b 1.7 45c 2 45d 24 Construction Type (1-4) 46a 1 47a 0 48a 0 10. FOUNDATION WALLS BELOW GRADE Depth Length Below Grade Wall Location (ft) (ft) (1-2) 46b 218 46c 7.5 46d 1 4 47b 0 47c 0 47d 0 4 48b 0 48c 0 48d 0 4 Wall Insulat (R-Value) 13 0 0 ENERGY SCORE Data Listing Input Worksheet: A:901-SOMM.WS Date: 09-08-1998 Reference Number: 241001 12. SLAB FLOORS (ON OR BELOW GRADE) Exposed Floor Area Perimeter Perimeter Insulation (sq ft) (ft) (R-Value) 52a 1998 52b 220 52c 0 53a 0 53b 0 53c 0 Under Slab Depth Width of Insulation Insulation Below Grade Under Slab (R-Value) (ft) (ft) 52d 0 52e 7 52f 0 53d 0 53e 0 53f 0 13. INTERIOR FINISH Drywall Thickness (0.5 to 1 in.) 54 .5 Uncarpeted Floor Slab (l.yes, 2.no) 55 2 Uncarpeted Floor Slab Area (sq ft) 56 0 Uncarpeted Floor Slab Thickness (in.) 57 4 14. ADDITIONAL MASS Mass Type Mass Area Mass Thickness (1-3) (sq ft) (in.) 58a 0 58b 0 58c 0 59a 0 59b 0 59c 0 Volume of Cond. Space (cubic ft) 60 34965 15. INFILTRATION Type of Infiltration Measurement (1-3) 61 1 6: Infiltration Value (ACH or sq.in) .4 16. HEATING EQUIPMENT Heating Heating System Type System AFUE Furnace Input (1-7) (%) (1000's Btu/h) 63 1 64 80 65 100 66 Electric Demand Control (l.yes, 2.no) 2 ENERGY SCORE Data Listing Date: 09-08-1998 Input Worksheet: A:901-SOMM.WS Reference Number: 241001 17. DUCTS AND PIPES Duct or Pipe Area in Attic above Insulation (sq ft) 67 0 Attic Duct Insulation (l.yes, 2.no) 68 0 Duct or Pipe Area in Crawl Space or Unheated Basement (sq ft) 69 0 Crawl Space or Unheated Basement Duct Insulation (l.yes, 2.no) 70 0 18. DOMESTIC HOT WATER Water Heater Type (1-4) 71 1 Water Heater Efficiency (%) 72 54 60 34965 61 1 62 .4 16. HEATING EQUIPMENT Heating Heating Electric System Type System AFUE Furnace Input Demand Control (1-7) (%) (1000's Btu/h) (l.yes, 2.no) 63 1 64 80 65 100 66 2 ENERGY SCORE Data Listinq lnjaut Wczrksheet:- A:901-SOMM.WS Date: 09-08-1998 Reference Number: 241001 17. DUCTS AND PIPES Duct or Pipe Area in Attic above Insulation (sq ft) 67 0 Attic Duct Insulation (l.yes, 2.no) 68 0 Duct or Pipe Area in Crawl Space or Unheated Basement (sq ft) 69 0 Crawl Spare or UnheatedBasementDuct Insulation. (l.yes, 2.noi 70 v 18. DOMESTIC HOT WATER Water Heater Type (1-4) 71 1 Water Heater Efficiency (%) 72 54