Loading...
HomeMy WebLinkAbout901 Oakridge Dr - Correspondence/Building Inspection - 06/09/1995. qO1 044;te D*, ve ..c 1 Baldwin Construction, Inc. 301 East Lincoln Avenue (970) 482-7722 �,�"""a� Fort Collins, CO 80524 FAX (970) 484-7428 = June 9, 1995 g ,� Sharon K. Getz City of Fort Collins Plan Review 281 North College Avenue PO Box 580, Ft Collins, CO 80522-0580 Re: Miramont Sport Center Plan Review Comments Dear Ms. Getz, Enclosed you will find the metal building engineer's response to your request of May 9, 1995, item 95. It appears that the metal building supplied by Inland Buildings meets or exceeds the minimum requirements for this type of structure. However, please do not hesitate to call us if you need additional data. Sincerely, BALDWIN CONS T RHC T ION; INC. QAL�j �M - 4 Albert M. Hamill Project Manager cc: Fred Sauer Joe Frye, Vaught Frye , • Phone • Fax Z Baldwin Construction 301 E. Lincoln Ave. Ft. Collins, CO 80524 Re: Inland Job S2983-01 Miramont Tennis Center, Ft. Collins, CO Gentlemen: 2141 Second Avenue S.W. Cullman, Alabama 35055 (205)739-6827 (800) 438-1606 FAX (800) 438-1626 jt, N 1995 June 5, 1995 The pre-engineered structural steel components for the above referenced project has been designed and fabricated by an A.I.S.C. member manufacturer, in accordance with the order documents and in general accordance with the latest procedures and design criteria of the following specifications; 1. AISC: Specification for the Design of Structural Steel for Buildings, 1989 Edition. 2. AISI: Specification for the Design of Cold -Formed Steel Structural Members, 1986 Edition. 3. MBMA: Low Rise Building Systems Manual 1989 Edition, with 1990 Supplements. The structural analysis has been based on the following criteria: 1. Building Code: UBC 1991 2. Roof Live Load: 30.0 psf (Non-reducable) 3. Roof Snow Load: 30.0 psf (Minimum) 4. Roof Dead Load: 2.0 psf plus frame weight 5. Wind Load: 100 mph, Exposure "C" 6. Seismic Load: Zone 1 Our responsibility is limited to the structural performance of the pre-engineered components as designed and supplied by Inland Southern Corp. d/b/a Inland Buildings using the specification and load criteria described above. Inland Buildings cannot and will not guarantee the performance of any components subjected to field modifications not endorsed by Inland Buildings Engineering Services, or the performance of any gompen6pt subject to loads other than those described in the foregoing. ,;)0 /'EGi " Sinc rely, ` �/~ UN Keith Shedd, R.E Manager of Engineering INLAND S0UTHEaN"60RP0RATI0N