Loading...
HomeMy WebLinkAbout850 S Overland Trl - Special Inspections/Engineering - 01/18/1999FOUNDATION (I Engineering, AND SOILS Inc. January 18, 1999 Commission No. 2154-16-05-01 Valley Crest Homes P.O. Box 272272 For Collins, Colorado- 8-0527 Gentlemen: On January 11, 1999, we visually observed the excavation at Lot 15, Blocks 29 & 30, Scenic Trail, (805 S. Overland Trail), a subdivision of Fort Collins, Colorado. The purpose of this observation was to verify that the soil conditions encountered in the excavation are generally consistent with those outlined in the soils report performed by EEC, Job No. 1952074A, dated February 19, 1996. This letter is not intended to be a summary of the soils report and does not meet the disclosure requirements of Colorado Senate Bill 13, 6-6.5-101. A test pit was excavated to a depth_ of three (3)_ -feet below footing elevation. Bedrock and/or groundwater was not observed within three (3) feet of footing elevation. The subsurface conditions exposed in the excavation appeared to be generally consistent with those described in the above referenced soils report, which recommends a balanced spread footing type foundation system for these subsurface conditions. No water was encountered at a depth of approximately six (6) feet. We recommend that damp -proofing be installed at the foundation walls for all below grade, habitable living areas per 1991 UBC Section 2915. Due to the anticipated depth of groundwater below footing elevation, it is our opinion that a perimeter drain is not required for this structure. If you have any questions, please feel free to call. �ectfully ames A1, Cherry. P.E, - FOUNDATION ENGINEERING, CONSULTING ENGINEERS, LTD. JDE/pia 5110 Granite Street, Suite D -Loveland, Colorado 80538 •(970) 663-0138 *Fax (970) 663-1660 500 Kimbark Street, Suite 101 *Longmont, Colorado 80501 •(303) 702-0661 *Fax (303) 774-8413