February 15, 1999
Commission No. 2154-16-11-02
Valley Crest Homes
P.O. Box 272272
Fort Collins, Colorado 80527
Gentlemen:
We have visually observed the footing forms placed at the residence under construction at Lot 10,
Scenic View, (850 S. Overland Trail), a subdivision of Fort Collins, Colorado. This observation
was performed on February 12, 1999.
It is our opinion that the form widths are in substantial conformance with our foundation plan, Job
No. 2154-16-02-01. No substantial amounts of loose material were noted below footing, wall or pad
bearing locations.
If you have any questions, please feel free to call.
Resp ctfull
James. A. Sherry, P.E.
FOUNDATION ENGINtERING, CONSULTING ENGINEERS, LTD.
CPH/pia
5110 Granite Street, Suite D -Loveland, Colorado 80538 •(970) 663-0138 *Fax (970) 663-1660
500 Kimbark Street, Suite 101 -Longmont, Colorado 80501 •(303) 702-0661 •Fax (303) 774-8413
�DDATIOIV
OILS II Engineering,
n
April2, 1999
Commission No.
2154-16-11-01
Valley Crest Homes
P•O. Box 272272
Fort Collins, Colorado
Gentlemen.
80527
On February 3 1999
Trail), a sub ' we visually observed the e the soil conditions Fort Collins excavation at Lot 10 S soils re ns encountered in the Colorado. The purpose Scenic port performed excavation p View' (8S0 S. Overland
the soils re by EEC, Job n are °f this observation was to port and doe No. 1952074q generally consistent with t
snot meet the disclosure This letter is verify that
hose outlined in the
A test urerequirements not intended to be
pit was excavated to a Of Col
observed within three SenateBi1113su�� °f
O feet o depth of three (3) feet below 6-6.5-101.
3 footin w footin
The su g elevation. g elevation.
described - ace conditions ex Bedrock was not
in the above exposed in the exc
system for these referenced soils re avation appeared subsurface conditions. Noort, Which recommend
be generally consistent
(8) feet. minend
water was encountered a spread footin With those
at a depth g type foundation
We recommend that d p ofapprOxi
living amp_proofin mately eight
g areas per 1991 g be installed
UBC Section 2915. at thefoundation walls for all bel
It is our opinion that Perimeter drain is not reqgrade
a meter ,habitable
structure.
ow
If you have any questions, please
uired for this
feel free to call.
Re ctfully,
J es A. Cherry P.E,
FOUNDgTION ENGINEERING
CONSULf'ING ENGINEERS
RDJ/pia
LTD.